Installation and operation manual

11

FMCQ50~125A8VEB

Air conditioning system

4PW56204-1

W

IRING

 

DIAGRAM

Indoor unit

A1P,A2P .............. Printed circuit board

C1........................ Capacitor

F1U ..................... Fuse (T, 5 A, 250 V)

HAP..................... Light emitting diode (service monitor - green)

KPR..................... Magnetic relay (drain pump)

L1 ........................ Coil

M1F ..................... Motor (indoor fan)

M1P..................... Motor (drain pump)

M1S..................... Motor (swing flap)

PS ....................... Power supply circuit

Q1DI.................... Earth leak detector

R1T ..................... Thermistor (air)

R2T ..................... Thermistor (coil)

R3T ..................... Thermistor (header)

S1L...................... Float switch

X1M,X2M ............ Terminal strip

Y1E ..................... Electronic expansion valve

Z1C ..................... Ferrite core

Wired remote controller

R1T......................Thermistor (air)

SS1......................Selector switch (MAIN/SUB)

Receiver/display unit (attached to wireless remote controller)

A3P,A4P...............Printed circuit board

BS1......................ON/OFF button

H1P......................Light emmiting diode (On - Red)

H2P......................Light emmiting diode (Timer - Green)

H3P......................Light emmiting diode (Filter sign- Red)

H4P......................Light emmiting diode (Defrost - Orange)

SS1......................Selector switch (MAIN/SUB)

SS2......................Selector switch (wireless address set)

Connector for optional parts

X24A....................Connector (wireless remote controller)

X33A....................Connector (adaptor for wiring)

X35A....................Connector (group control adaptor)

X38A....................Connector

 (multi tenant)

Notes

1

: Terminal

: Connector

: Field wiring

2

In case of using a central remote controller, connect it to the unit in accordance with the attached installation manual.

3

X24A, X33A, and X35A are connected when the optional accessories are being used.

4

When connecting the input wires from outside, FORCED OFF or ON/OFF CONTROL operation can be selected by the remote controller. See installation 
manual for more details

5

Confirm the method of setting the selector switch (SS1, SS2) by installation manual and engineering data, etc.

6

Colour legend

BLK

: Black

BLU

: Blue

ORG

: Orange

YLW

: Yellow

PNK

: Pink

RED

: Red

WHT

: White

GRN

: Green

BRN

: Brown

GRY

: Gray

Control box

:

Receiver/display unit

:

Central remote controller

:

Wired remote controller

:

Input from outside

:

Summary of Contents for FMCQ100A8VEB

Page 1: ...INSTALLATION AND OPERATION MANUAL FMCQ50A8VEB FMCQ60A8VEB FMCQ71A8VEB FMCQ100A8VEB FMCQ125A8VEB Air conditioning system...

Page 2: ...0 860 910 840 780 710 840 860 910 950 4 125 130 3 1 840 910 840 910 1 4 2 5 6 3 860 860 910 20 20 35 35 3 5 0 75 675 850 175 300 mm 1 1 5 m 2 3 1 5 6 100 mm 1 0 675 mm 1 3 4 3 1 2 4 100 90 mm 7 mm 80...

Page 3: ...lecido em A e com o parecer positivo de B de acordo com o Certificado C 09 A B C 10 Bem rk som anf rt i A og positivt vurderet af B i henhold til Certifikat C 11 Information enligt A och godk nts av B...

Page 4: ...lastic parts may deteriorate Where corrosive gas like sulphurous gas exists Copper tubing and brazed spots may corrode Where volatile flammable gas like thinner or gasoline is used Where machines gene...

Page 5: ...t the distance between wireless remote controller and indoor unit might be shorter if there are fluorescent lights who are electrically started in the room The indoor unit must be installed as far as...

Page 6: ...see figure 6 2 Fix the paper pattern for installation For new ceilings only The paper pattern for installation corresponds with the measure ments of the ceiling opening Consult the builder for details...

Page 7: ...tightening torque Overtightening may damage the flare and cause leaks Table 1 When connecting the flare nut coat the flare inner surface with ether oil or ester oil and initially tighten 3 or 4 turns...

Page 8: ...ose to insulate and fix it with clamps Insulate the complete drain piping inside the building field supply If the drain hose cannot be sufficiently set on a slope fit the hose with drain raising pipin...

Page 9: ...nit A unit B and be sure the terminal block wiring to the outdoor unit is matching properly If wiring and piping between the outdoor unit and an indoor unit are mismatched the system may cause a malfu...

Page 10: ...es according to the table below When attaching the control box lid make sure not to pinch any wires After all wiring connections are done fill in any gaps in the casing wiring holes with putty or insu...

Page 11: ...the remote controller sensor See note 5 6 Use unit sensor only or remote sensor if installed See note 5 6 Use remote controller sensor only See note 5 6 3 Setting for display of time between 2 filter...

Page 12: ...ining access to terminal devices all power supply circuits must be interrupted To clean the air conditioner be sure to stop operation and turn the power switch off Otherwise an electric shock and inju...

Page 13: ...panel Hold the suction grille open at 45 degrees and lift it upward to unhook it from the decoration panel 3 Remove the air filter actions 2 to 4 in the illustration Refer to procedure step 2 in How...

Page 14: ...H4P Light emmiting diode Defrost Orange SS1 Selector switch MAIN SUB SS2 Selector switch wireless address set Connector for optional parts X24A Connector wireless remote controller X33A Connector ada...

Page 15: ...1 F2 T1 T2 LN P1 P2 F1 F2 T1 T2 LN P1 P2 F1 F2 T1 T2 LN P1 P2 F1 F2 T1 T2 P1 P2 P1 P2 1 4 2 3 5 IN D OUT D F1 F2 F1 F2 Control box LN P1 P2 P1 P2 F1 F2 T1 T2 P1 P2 P1 P2 F1 F2 T1 T2 LN P1 P2 P1 P2 F1...

Page 16: ...4PW56204 1 Copyright Daikin...

Reviews: