![background image](http://html1.mh-extra.com/html/daikin/fl15exv1/fl15exv1_technical-manual_4700376025.webp)
22
Engineering & Physical Data
Safety Device
R22
MODEL
INDOOR
FL(Y)15EXV1
FL(Y)20EXV1
OUTDOOR
R(Y)15CXV1
RY18CXV1
R(Y)20CXV1
SAFETY
DEVICE
HIGH PRESSURE
SWITCH
TYPE
N/A
OPEN
kPa / psi
N/A
CLOSE
kPa / psi
N/A
LOW PRESSURE
SWITCH
TYPE
N/A
OPEN
kPa / psi
N/A
CLOSE
kPa / psi
N/A
PHASE SEQUENCER
N/A
DISC. THERMOSTAT SETTING
°C / F
N/A
MODEL
INDOOR
FL25EXV1
FL28EXV1
OUTDOOR
R25CXV1
R28CXV1
R30DXV1
SAFETY
DEVICE
HIGH PRESSURE
SWITCH
TYPE
N/A
N/A
NC
OPEN
kPa / psi
N/A
N/A
2937 / 426
CLOSE
kPa / psi
N/A
N/A
2413 / 350
LOW PRESSURE
SWITCH
TYPE
N/A
N/A
NC
OPEN
kPa / psi
N/A
N/A
124 / 18
CLOSE
kPa / psi
N/A
N/A
193 / 28
PHASE SEQUENCER
N/A
N/A
N/A
DISC. THERMOSTAT SETTING
°C / F
N/A
N/A
N/A
MODEL
INDOOR
FLY25EXV1
FLY28EXV1
OUTDOOR
RY25CXV1
RY28CXV1
RY30DXV1
SAFETY
DEVICE
HIGH PRESSURE
SWITCH
TYPE
N/A
N/A
NC
OPEN
kPa / psi
N/A
N/A
2937 / 426
CLOSE
kPa / psi
N/A
N/A
2413 / 350
LOW PRESSURE
SWITCH
TYPE
N/A
N/A
N/A
OPEN
kPa / psi
N/A
N/A
N/A
CLOSE
kPa / psi
N/A
N/A
N/A
PHASE SEQUENCER
N/A
N/A
N/A
DISC. THERMOSTAT SETTING
°C / F
N/A
N/A
N/A
MODEL
INDOOR
FL35EXV1
FL40EXV1
FL40EXV1
OUTDOOR
R35DXV1
R40DXV1
R40DXY1
SAFETY
DEVICE
HIGH PRESSURE
SWITCH
TYPE
NC
OPEN
kPa / psi
2937 / 426
CLOSE
kPa / psi
2413 / 350
LOW PRESSURE
SWITCH
TYPE
NC
OPEN
kPa / psi
124 / 18
CLOSE
kPa / psi
192 / 28
PHASE SEQUENCER
N/A
YES
DISC. THERMOSTAT SETTING
°C / F
N/A
N/A
ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
DAIKIN_FL(Y).indb 22
DAIKIN_FL(Y).indb 22
9/27/2012 12:13:20 PM
9/27/2012 12:13:20 PM
Summary of Contents for FL15EXV1
Page 2: ......
Page 58: ...55 Wiring Diagrams Indoor Unit Model FL35EXV1 Outdoor Unit Model R35DXV1...
Page 59: ...56 Wiring Diagrams Indoor Unit Model FL40EXV1 Outdoor Unit Model R40DXV1...
Page 63: ...60 Wiring Diagrams Heatpump Indoor Unit Model FLY15EXV1 Outdoor Unit Model RY15CXV1...
Page 64: ...61 Wiring Diagrams Indoor Unit Model FLY20 25EXV1 Outdoor Unit Model RY18 20 25CXV1...
Page 66: ...63 Wiring Diagrams Indoor Unit Model FLY28EXV1 Outdoor Unit Model RY30DXV1...
Page 67: ...64 Wiring Diagrams Indoor Unit Model FLY35EXV1 Outdoor Unit Model RY35DXV1...
Page 68: ...65 Wiring Diagrams Indoor Unit Model FLY40EXV1 Outdoor Unit Model RY40DXV1...
Page 69: ...66 Wiring Diagrams Indoor Unit Model FLY40EXV1 Outdoor Unit Model RY40DXY1...
Page 78: ......