background image

• Indoor Unit  • Ceiling suspended  unit  • FHQ-C

1

2

• Split -  Sky Air  • Indoor Unit

4

2

Specifications

Standard Accessories : Screw for wiring fixture;
Standard Accessories : Wiring fixture;
Standard Accessories : Resin bushing;
Standard Accessories : Sealing material;
Standard Accessories : Joint insulating material;
Standard Accessories : Installation pattern;
Standard Accessories : Clamps;
Standard Accessories : Washer for hanger bracket;
Standard Accessories : Clamp metal;
Standard Accessories : Drain hose;
Standard Accessories : Declaration of conformity;
Standard Accessories : Operation manual;
Standard Accessories : Installation manual;

Sound pressure level

Cooling

High/Nom./Low

dBA

36/34/31

37/35/32

37/35/33

38/36/34

42/38/34

44/41/37

46/42/38

Heating

Super high/High/
Nom./Low

dBA

-/36/34/31

-/37/35/32

-/37/35/33

-/38/36/34

-/42/38/34

-/44/41/37

-/46/42/38

Refrigerant

Type

R-410A

Piping connections

Sound absorbing insulation

Not needed

Liquid

Type/OD

mm

C1220T (Flare connection)/6.35

C1220T (Flare connection)/9.52

Gas

Type/OD

mm

C1220T 

(Flare 

connection)/

9.5

C1220T (Flare connection)/

12.7

C1220T (Flare connection)/15.9

Drain

VP20

Heat insulation

Needed

Air direction control

Up and downwards

Air filter

Type

Resin net with mold resistance

Quantity

pc

2

Safety devices

Item

01

Fuse (F, 5A, 250V)

-

2-2 Electrical Specifications

FHQ35C

FHQ50C

FHQ60C

FHQ71C

FH Q100 C

FHQ125C

FHQ140C

Power supply

Name

VE

Phase

1~

Frequency

Hz

50/60

Voltage

V

220-240/220

Current - 50Hz

Maximum running current

A

0.6

0.8

1.3

1.5

1.8

Current - 60Hz

Nominal running current

A

-

2-1 Technical Specifications

FHQ35C

FHQ50C

FHQ60C

FHQ71C

FH Q100 C

FHQ125C

FHQ140C

Summary of Contents for FHQ-C

Page 1: ...Air Conditioning Technical Data Ceiling suspended unit EEDEN13 100 FHQ C...

Page 2: ......

Page 3: ...Electrical Specifications 4 3 Safety device settings 5 Safety Device Settings 5 4 Options 6 Options 6 5 Dimensional drawings 7 Dimensional Drawings 7 6 Piping diagrams 10 Piping Diagrams 10 7 Wiring...

Page 4: ...Keep track of your energy consumption with the kWh indication showing an indicative electricity consumption Can be installed in both new and existing buildings Setup to 3 independent schedules so the...

Page 5: ...Sirocco fan Quantity 2 4 Air flow rate Cooling High m min 14 15 19 5 20 5 28 31 34 cfm 494 530 689 724 989 1 095 1 201 Nom m min 11 5 12 15 17 24 27 29 cfm 406 424 530 600 848 953 1 024 Low m min 10 1...

Page 6: ...38 34 44 41 37 46 42 38 Heating Super high High Nom Low dBA 36 34 31 37 35 32 37 35 33 38 36 34 42 38 34 44 41 37 46 42 38 Refrigerant Type R 410A Piping connections Sound absorbing insulation Not ne...

Page 7: ...3 1 3 Split Sky Air Indoor Unit 5 Indoor Unit Ceiling suspended unit FHQ C 3 Safety device settings 3 1 Safety Device Settings...

Page 8: ...Indoor Unit Ceiling suspended unit FHQ C 1 4 Split Sky Air Indoor Unit 6 4 Options 4 1 Options...

Page 9: ...3 1 5 Split Sky Air Indoor Unit 7 Indoor Unit Ceiling suspended unit FHQ C 5 Dimensional drawings 5 1 Dimensional Drawings...

Page 10: ...Indoor Unit Ceiling suspended unit FHQ C 1 5 Split Sky Air Indoor Unit 8 5 Dimensional drawings 5 1 Dimensional Drawings...

Page 11: ...3 1 5 Split Sky Air Indoor Unit 9 Indoor Unit Ceiling suspended unit FHQ C 5 Dimensional drawings 5 1 Dimensional Drawings...

Page 12: ...Indoor Unit Ceiling suspended unit FHQ C 1 6 Split Sky Air Indoor Unit 10 6 Piping diagrams 6 1 Piping Diagrams...

Page 13: ...3 1 7 Split Sky Air Indoor Unit 11 Indoor Unit Ceiling suspended unit FHQ C 7 Wiring diagrams 7 1 Wiring Diagrams Single Phase...

Page 14: ...Indoor Unit Ceiling suspended unit FHQ C 1 8 Split Sky Air Indoor Unit 12 8 External connection diagrams 8 1 External Connection Diagrams...

Page 15: ...3 1 9 Split Sky Air Indoor Unit 13 Indoor Unit Ceiling suspended unit FHQ C 9 Sound data 9 1 Sound Pressure Spectrum...

Page 16: ...Indoor Unit Ceiling suspended unit FHQ C 1 9 Split Sky Air Indoor Unit 14 9 Sound data 9 1 Sound Pressure Spectrum...

Page 17: ...ED EN13 100 1 1 12 Cop yrigh t Da ikin The p resen t pu bli cation su perse des EEDEN 12 1 00 The present leaflet is drawn up byway ofinformati on only and does not constitute an offer binding upon Da...