FHYC40JEVLK - RYD40JEVLK
FHYC50JEVLK - RYD50JETLK
Indoor Unit
Terminal Block
Interconnection Cable
Outdoor Unit
Terminal Block
Power Supply Cable
Model
Indoor
FHYC50JEVLK
Outdoor
RYD50JETLK
Voltage range**
Indoor
220V/1Ph/60Hz +
!
Outdoor
220V/3N~/60Hz +
!
Power supply cable size*
mm
2
Number of conductors
6.0
3
Interconnection cable size*
mm
2
Number of conductors
2.5
4 & 3
Recommended time delay fuse*
A
35
Model
Indoor
FHYC40JEVLK
Outdoor
RYD40JEVLK
Voltage range**
Indoor
220V/1Ph/60Hz +
!
Outdoor
220V/1Ph/60Hz +
!
Power supply cable size*
mm
2
Number of conductors
6.0
3
Interconnection cable size*
mm
2
Number of conductors
2.5
4 & 3
Recommended time delay fuse*
A
35
Outdoor Coil Sensor
Interconnection Cable
Indoor Unit
Terminal Block
Outdoor Unit
Terminal Block
Power Supply Cable
There must be an all pole
disconnection in the supply
mains with a contact separation
of at least 3mm.