background image

 

Operation manual

6

FFQ25~60C2VEB

Split system air conditioners

4P341089-1A – 2013.01

Troubleshooting

If one of the following malfunctions occurs, take the measures shown
below and contact your dealer.

The system must be repaired by a qualified service person.

If a safety device such as a fuse, a breaker, or an earth leakage
breaker frequently actuates, or ON/OFF switch does not
properly work.
Measure: Turn off the main power switch.

If water leaks from unit.
Measure: Stop the operation.

If the display "

" (INSPECTION), "

", and the

OPERATION lamp flashes and the "MALFUNCTION CODE"
appears.
Measure: Notify your dealer and inform him/her of the display.

If the system does not operate properly, except for the above
mentioned case, and none of the above mentioned malfunctions are
evident, investigate the system according to the following procedures.

If the system does not operate at all.

Check if there is a power failure.
Wait until power is restored. If power failure occurs during
operation, the system automatically restarts immediately after
the power supply recovers.

Check if the fuse has blown or breaker has been tripped.
Change the fuse or set the breaker.

If the system stops operating after operation is complete.

Check if the air inlet or outlet of outdoor or indoor unit is blocked
by obstacles.
Remove the obstacle and make it well-ventilated.

Check if the air filter is clogged.
Ask a qualified service person to clean the air filter.

The system operates but it does not sufficiently cool or heat.

If the air inlet or outlet of the indoor or the outdoor unit is blocked
with obstacles.
Remove the obstacle and make it well-ventilated.

If the air filter is clogged.
Ask a qualified service person to clean the air filter.

If the set temperature is not proper. (Refer to the manual of the
remote controller)

If the FAN SPEED CONTROL button is set to LOW SPEED.
(Refer to the manual of the remote controller)

If the air flow angle is not proper. (Refer to the manual of the
remote controller)

If the doors or the windows are open. Shut doors or windows to
prevent wind from coming in.

If direct sunlight enters the room (when cooling).
Use curtains or blinds.

When there are too many inhabitants in the room. Cooling effect
decreases if heat gain of the room is too large.

If the heat source of the room is excessive (when cooling).
Cooling effect decreases if heat gain of the room is too large.

Disposal requirements

Dismantling of the unit, treatment of the refrigerant, of oil and of other
parts must be done in accordance with relevant local and national
legislation.

Your air conditioning product is marked with this symbol.
This means that electrical and electronic products shall
not be mixed with unsorted household waste.

Do not try to dismantle the system yourself: the dismantling of the air
conditioning system, treatment of the refrigerant, of oil and of other
parts must be done by a qualified installer in accordance with
relevant local and national legislation.

Air conditioners must be treated at a specialized treatment facility for
re-use, recycling and recovery. By ensuring this product is disposed
of correctly, you will help to prevent potential negative consequences
for the environment and human health. Please contact the installer or
local authority for more information.

Batteries must be removed from the remote controller and disposed
of separately in accordance with relevant local and national
legislation.

WARNING

When the air conditioner is in abnormal conditions (burning
smell, etc.) unplug the power cord from the outlet and
contact your dealer.

Continued operation under such circumstances may result
in a failure, electric shock and fire.

Summary of Contents for FFQ25C2VEB

Page 1: ...OPERATION MANUAL FFQ25C2VEB FFQ35C2VEB FFQ50C2VEB FFQ60C2VEB Split system air conditioners...

Page 2: ...80 5MXS90 80 80 80 80 80 10 46 15 46 10 46 15 50 5 46 C DB C WB C DB C WB RZQ200 250 18 35 14 28 80 5 46 C DB C WB C DB C WB C DB C WB C DB C WB C DB C WB C DB C WB C DB C DB C DB C WB 18 35 14 28 RZ...

Page 3: ...whenever necessary If the equipment is transferred to a new user be sure also to hand over the manual Warning Be aware that prolonged direct exposure to cool or warm air from the air conditioner or to...

Page 4: ...dren should be supervised to ensure that they do not play with the appliance This appliance is intended to be used by expert or trained users in shops in light industry and on farms or for commercial...

Page 5: ...for closing 2 Remove the air filter See figure 6 actions 2 to 4 in the illustration Pull the air filter clip on both the bottom left and the right side of the filter toward you and detach the filter...

Page 6: ...not blocked Remove any obstacle Check if the earth is connected Is there a broken wire somewhere Contact your dealer if there are any problems Clean the air filter and outside panels After cleaning t...

Page 7: ...an speed control button does not change the fan speed When the room temperature reaches the set temperature in heating mode the capacity supply from the outdoor unit has stopped and the indoor unit op...

Page 8: ...t temperature is not proper Refer to the manual of the remote controller If the FAN SPEED CONTROL button is set to LOW SPEED Refer to the manual of the remote controller If the air flow angle is not p...

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ...4P341089 1A 2013 01 Copyright 2013 Daikin...