background image

FFQ25~60C2VEB
Split system air conditioners
4P341089-1A – 2013.01

Operation manual

3

Operation procedure

Optimum operation

Observe the following precautions to ensure the system operates
properly.

Fully use the function of air flow direction adjustment.
As cold air gathers on the floor and warm air gathers against the
ceiling, it is recommended to set the air flow direction during
cooling or dry operation parallel to the ceiling and to set it
downwards during heating operation.
Beware on the other hand, to avoid direct air flow to room
inhabitants.

Adjust the room temperature properly for a comfortable
environment. Avoid excessive heating or cooling.
Notice that it may take some time for the room temperature to
reach the set temperature. Consider therefore to take advantage
of the timer setting possibilities.

Prevent direct sunlight from entering a room during cooling
operation by using curtains or blinds.

Ventilate the room regularly. Using the unit for long periods of
time requires attentive ventilation of the room.

Do not operate the air conditioner when using a room
fumigation-type insecticide.
Failure to observe this could cause the chemicals to become
deposited in the unit, which could endanger the health of those
who are hypersensitive to chemicals.

Keep doors and windows closed. If the doors and windows
remain open, room air will flow out and decrease the effect of
cooling and heating.

Never place objects near the air inlet and the air outlet of the
unit. It may retard effectiveness or cause operation to stop.

Turn off the main power supply switch when not using for long
periods of time. Electricity is consumed as long as the switch is
on. Turn off the main power supply switch in order to save
energy. Turn on the main power supply switch 6 hours before
restarting operation in order to ensure smooth operation. (Refer
to 

"Maintenance" on page 3

.)

When the display shows "

" (TIME TO CLEAN AIR

FILTER), have a qualified service person to clean the filters.
(Refer to 

"Maintenance" on page 3

.)

Maintenance

How to clean the air filter

Clean the air filter when the display shows "

" (TIME TO CLEAN

AIR FILTER).
Increase the frequency of cleaning if the unit is installed in a room
where the air is extremely contaminated.
(As a yardstick for yourself, consider cleaning the filter once half a year.)
If the dirt becomes impossible to clean, change the air filter. (Air filter
for exchange is optional.)

In case of decoration panel BYFQ60C see figures marked 

A

BYFQ60B see figures marked 

B

1

Open the suction grille 

(See figure 5)

 (action 1 in the illustration).

Push both levers simultaneously in the direction of the arrow as
indicated in the illustration and carefully lower the grille.
(Identical procedure for closing.)

2

Remove the air filter 

(See figure 6)

 (actions 2 to 4 in the

illustration).
Pull the air filter clip on both the bottom left and the right side of
the filter toward you, and detach the filter.

3

Clean the air filter. 

(See figure 3)

Use vacuum cleaner or wash the air filter with water.
When the air filter is very dirty, use soft brush and neutral
detergent.

4

Remove water and dry in the shade.

5

Install the air filter back in place (perform actions 2 to 4 in the
illustration in reverse order).
Attach the air filter to the suction grille by hanging it over the
projected portion above the suction grille.
Press the bottom of the air filter against the projections on the
bottom of the grille to snap the air filter into its place.

6

Close the suction grille by performing procedure step 1 in
reverse order.

7

After turning on the power, press the FILTER SIGN RESET button.
The "TIME TO CLEAN AIR FILTER" display vanishes.

NOTE

Contact your dealer in case of changing the
combination or setting of group control and two remote
controller control systems.

Read the operation manual supplied with the remote
controller.

If a function that is not available is selected, the
message NOT AVAILABLE will appear.

Operating procedure varies with heat pump type and
straight cooling type. Contact your dealer to confirm
your system type.

To protect the unit, turn on the main power switch
6 hours before operation.

If the main power supply is turned off during
operation, operation will restart automatically after the
power turns back on again.

NOTE

Set the temperature within the ranges mentioned
under 

"Operation range" on page 2

.

Do not use the air conditioner for other purposes.

In order to avoid any quality deterioration, do not use the
unit for cooling precision instruments, food, plants, animals
or works of art.

CAUTION

Only a qualified service person is allowed to perform
maintenance.

Before obtaining access to terminal devices, all power
supply circuits must be interrupted.

To clean the air conditioner or air filter, be sure to stop
operation and turn all power supplies off.
Otherwise, an electric shock and injury may result.

Do not wash the air conditioner with water.
Doing so may result in an electric shock.

Be careful with scaffoldings.
Caution must be exercised when working in high
places.

After a long use, check the unit stand and fitting for
damage. If damaged, the unit may fall and cause
injury.

Do not touch the heat exchanger fins.
The fins are sharp and could result in cutting injuries.

When cleaning the heat exchanger, be sure to remove
the control box, fan motor, drain pump and float
switch. Water or detergent may deteriorate the
insulation of electronic components and result in burn-
out of these components.

NOTE

Do not wash the air filter with hot water of more than
50°C. Doing so may result in discoloration and/or
deformation.
Do not expose the unit to fire. Doing so may result in
burning.

Summary of Contents for FFQ25C2VEB

Page 1: ...OPERATION MANUAL FFQ25C2VEB FFQ35C2VEB FFQ50C2VEB FFQ60C2VEB Split system air conditioners...

Page 2: ...80 5MXS90 80 80 80 80 80 10 46 15 46 10 46 15 50 5 46 C DB C WB C DB C WB RZQ200 250 18 35 14 28 80 5 46 C DB C WB C DB C WB C DB C WB C DB C WB C DB C WB C DB C WB C DB C DB C DB C WB 18 35 14 28 RZ...

Page 3: ...whenever necessary If the equipment is transferred to a new user be sure also to hand over the manual Warning Be aware that prolonged direct exposure to cool or warm air from the air conditioner or to...

Page 4: ...dren should be supervised to ensure that they do not play with the appliance This appliance is intended to be used by expert or trained users in shops in light industry and on farms or for commercial...

Page 5: ...for closing 2 Remove the air filter See figure 6 actions 2 to 4 in the illustration Pull the air filter clip on both the bottom left and the right side of the filter toward you and detach the filter...

Page 6: ...not blocked Remove any obstacle Check if the earth is connected Is there a broken wire somewhere Contact your dealer if there are any problems Clean the air filter and outside panels After cleaning t...

Page 7: ...an speed control button does not change the fan speed When the room temperature reaches the set temperature in heating mode the capacity supply from the outdoor unit has stopped and the indoor unit op...

Page 8: ...t temperature is not proper Refer to the manual of the remote controller If the FAN SPEED CONTROL button is set to LOW SPEED Refer to the manual of the remote controller If the air flow angle is not p...

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ...4P341089 1A 2013 01 Copyright 2013 Daikin...

Reviews: