Operation procedure
Optimum operation
Observe the following precautions to ensure the system operates
properly.
Fully use the function of air flow direction adjustment.
As cold air gathers on the floor and warm air gathers against the
ceiling, it is recommended to set the air flow direction during
cooling or dry operation parallel to the ceiling and to set it
downwards during heating operation.
Beware on the other hand, to avoid direct air flow to room
inhabitants.
Adjust the room temperature properly for a comfortable
environment. Avoid excessive heating or cooling.
Notice that it may take some time for the room temperature to
reach the set temperature. Consider therefore to take advantage
of the timer setting possibilities.
Prevent direct sunlight from entering a room during cooling
operation by using curtains or blinds.
Ventilate the room regularly. Using the unit for long periods of
time requires attentive ventilation of the room.
Do not operate the air conditioner when using a room
fumigation-type insecticide.
Failure to observe this could cause the chemicals to become
deposited in the unit, which could endanger the health of those
who are hypersensitive to chemicals.
Keep doors and windows closed. If the doors and windows
remain open, room air will flow out and decrease the effect of
cooling and heating.
Never place objects near the air inlet and the air outlet of the
unit. It may retard effectiveness or cause operation to stop.
Turn off the main power supply switch when not using for long
periods of time. Electricity is consumed as long as the switch is
on. Turn off the main power supply switch in order to save
energy. Turn on the main power supply switch 6 hours before
restarting operation in order to ensure smooth operation. (Refer
to
"Maintenance" on page 3
.)
When the display shows "
" (TIME TO CLEAN AIR
FILTER), have a qualified service person to clean the filters.
(Refer to
"Maintenance" on page 3
.)
Maintenance
How to clean the air filter
Clean the air filter when the display shows "
" (TIME TO CLEAN
AIR FILTER).
Increase the frequency of cleaning if the unit is installed in a room
where the air is extremely contaminated.
(As a yardstick for yourself, consider cleaning the filter once half a year.)
If the dirt becomes impossible to clean, change the air filter. (Air filter
for exchange is optional.)
In case of decoration panel BYFQ60C see figures marked
A
BYFQ60B see figures marked
B
1
Open the suction grille
(See figure 5)
(action 1 in the illustration).
Push both levers simultaneously in the direction of the arrow as
indicated in the illustration and carefully lower the grille.
(Identical procedure for closing.)
2
Remove the air filter
(See figure 6)
(actions 2 to 4 in the
illustration).
Pull the air filter clip on both the bottom left and the right side of
the filter toward you, and detach the filter.
3
Clean the air filter.
(See figure 3)
Use vacuum cleaner or wash the air filter with water.
When the air filter is very dirty, use soft brush and neutral
detergent.
4
Remove water and dry in the shade.
5
Install the air filter back in place (perform actions 2 to 4 in the
illustration in reverse order).
Attach the air filter to the suction grille by hanging it over the
projected portion above the suction grille.
Press the bottom of the air filter against the projections on the
bottom of the grille to snap the air filter into its place.
6
Close the suction grille by performing procedure step 1 in
reverse order.
7
After turning on the power, press the FILTER SIGN RESET button.
The "TIME TO CLEAN AIR FILTER" display vanishes.
NOTE
Contact your dealer in case of changing the
combination or setting of group control and two remote
controller control systems.
Read the operation manual supplied with the remote
controller.
If a function that is not available is selected, the
message NOT AVAILABLE will appear.
Operating procedure varies with heat pump type and
straight cooling type. Contact your dealer to confirm
your system type.
To protect the unit, turn on the main power switch
6 hours before operation.
If the main power supply is turned off during
operation, operation will restart automatically after the
power turns back on again.
NOTE
Set the temperature within the ranges mentioned
under
"Operation range" on page 2
.
Do not use the air conditioner for other purposes.
In order to avoid any quality deterioration, do not use the
unit for cooling precision instruments, food, plants, animals
or works of art.
CAUTION
Only a qualified service person is allowed to perform
maintenance.
Before obtaining access to terminal devices, all power
supply circuits must be interrupted.
To clean the air conditioner or air filter, be sure to stop
operation and turn all power supplies off.
Otherwise, an electric shock and injury may result.
Do not wash the air conditioner with water.
Doing so may result in an electric shock.
Be careful with scaffoldings.
Caution must be exercised when working in high
places.
After a long use, check the unit stand and fitting for
damage. If damaged, the unit may fall and cause
injury.
Do not touch the heat exchanger fins.
The fins are sharp and could result in cutting injuries.
When cleaning the heat exchanger, be sure to remove
the control box, fan motor, drain pump and float
switch. Water or detergent may deteriorate the
insulation of electronic components and result in burn-
out of these components.
NOTE
Do not wash the air filter with hot water of more than
50°C. Doing so may result in discoloration and/or
deformation.
Do not expose the unit to fire. Doing so may result in
burning.