14 Troubleshooting

Installation and operation manual

20

FFA25~60A2VEB

Split system air conditioners

4P456960-1 – 2017.03

NOTICE

▪ The  table  indicates  main  components.  Refer  to  your

maintenance and inspection contract for more details.

▪ The  table  indicates  recommended  intervals  of

replacement cycles. However, in order to keep the unit
operational as long as possible, maintenance work may
be  required  sooner.  Recommended  intervals  can  be
used  for  appropriate  maintenance  design  in  terms  of
budgeting  maintenance  and  inspection  fees.  Contact
your dealer for details.

INFORMATION

Damage due to taking apart or cleaning interiors of units by
anyone  other  than  our  authorised  dealers  may  not  be
included in the warranty.

14

Troubleshooting

If one of the following malfunctions occur, take the measures shown
below and contact your dealer.

WARNING

Stop  operation  and  shut  off  the  power  if  anything
unusual occurs (burning smells etc.).

Leaving  the  unit  running  under  such  circumstances  may
cause breakage, electric shock or fire. Contact your dealer.

The system must be repaired by a qualified service person:

Malfunction

Measure

If a safety device such as a fuse, a
breaker or an earth leakage breaker
frequently actuates or the ON/OFF
switch does not properly work.

Turn off the main power
switch.

If water leaks from the unit.

Stop the operation.

The operation switch does not work
well.

Turn off the power.

If the user interface display indicates the
unit number, the operation lamp flashes
and the malfunction code appears.

Notify your installer and
report the malfunction
code.

If  the  system  does  not  properly  operate  except  for  the  above
mentioned cases and none of the above mentioned malfunctions is
evident,  investigate  the  system  according  to  the  following
procedures.

Malfunction

Measure

If the system does not
operate at all.

▪ Check  if  there  is  no  power  failure.  Wait

until  power  is  restored.  If  power  failure
occurs  during  operation,  the  system
automatically  restarts  immediately  after
power is restored.

▪ Check if no fuse has blown or breaker is

activated.  Change  the  fuse  or  reset  the
breaker if necessary.

Malfunction

Measure

The system operates
but cooling or heating
is insufficient.

▪ Check  if  air  inlet  or  outlet  of  outdoor  or

indoor  unit  is  not  blocked  by  obstacles.
Remove  any  obstacles  and  make  sure
the air can flow freely.

▪ Check  if  the  air  filter  is  not  clogged  (see

"13.1.1  To  clean  the  air  filter"  on
page 17

).

▪ Check the temperature setting.

▪ Check the fan speed setting on your user

interface.

▪ Check for open doors or windows. Close

doors and windows to prevent wind from
coming in.

▪ Check if there are too many occupants in

the room during cooling operation. Check
if  the  heat  source  of  the  room  is
excessive.

▪ Check  if  direct  sunlight  enters  the  room.

Use curtains or blinds.

▪ Check if the air flow angle is proper.

If  after  checking  all  above  items,  it  is  impossible  to  fix  the  problem
yourself, contact your installer and state the symptoms, the complete
model name of the unit (with manufacturing number if possible) and
the installation date (possibly listed on the warranty card).

14.1

Symptoms that are NOT system
malfunctions

The following symptoms are NOT system malfunctions:

14.1.1

Symptom: The system does not operate

▪ The  air  conditioner  does  not  start  immediately  after  the  ON/OFF

button  on  the  user  interface  is  pressed.  If  the  operation  lamp
lights, the system is in normal condition. To prevent overloading of
the compressor motor, the air conditioner starts 5 minutes after it
is  turned  ON  again  in  case  it  was  turned  OFF  just  before.  The
same  starting  delay  occurs  after  the  operation  mode  selector
button was used.

▪ If  "Under  Centralized  Control"  is  displayed  on  the  user  interface,

pressing the operation button causes the display to blink for a few
seconds.  The  blinking  display  indicates  that  the  user  interface
cannot be used.

▪ The  system  does  not  start  immediately  after  the  power  supply  is

turned  on.  Wait  one  minute  until  the  micro  computer  is  prepared
for operation.

14.1.2

Symptom: The fan strength does not
correspond to the setting

The  fan  speed  does  not  change  even  if  the  fan  speed  adjustment
button  in  pressed.  During  heating  operation,  when  the  room
temperature  reaches  the  set  temperature,  the  outdoor  unit  goes  off
and the indoor unit changes to whisper fan speed. This is to prevent
cold  air  blowing  directly  on  occupants  of  the  room.  The  fan  speed
will not change if the button is pressed.

14.1.3

Symptom: The fan direction does not
correspond to the setting

The  fan  direction  does  not  correspond  with  the  user  interface
display. The fan direction does not swing. This is because the unit is
being controlled by the micro computer.

Summary of Contents for FFA25A2VEB

Page 1: ...Installation and operation manual Split system air conditioners English Installation and operation manual Split system air conditioners FFA25A2VEB FFA35A2VEB FFA50A2VEB FFA60A2VEB ...

Page 2: ...mitate cu instrucţiunile noastre skladni z naslednjimi standardi in drugimi normativi pod pogojem da se uporabljajo v skladu z našimi navodili on vastavuses järgmis t e standardi te ga või teiste normatiivsete dokumentidega kui neid kasutatakse vastavalt meie juhenditele съответстват на следните стандарти или други нормативни документи при условие че се използват съгласно нашите инструкции atitink...

Page 3: ...e heating operation 16 12 2 4 To operate the system 16 12 3 Using the dry program 16 12 3 1 About the dry program 16 12 3 2 To use the dry program 16 12 4 Adjusting the air flow direction 16 12 4 1 About the air flow flap 16 13 Maintenance and service 17 13 1 Cleaning the air filter suction grille air outlet and outside panels 17 13 1 1 To clean the air filter 17 13 1 2 To clean the suction grille...

Page 4: ... precautions c Indoor unit installation and operation manual d Washers for hanger bracket e Screws f Cable ties g Metal clamp h Sealing pads Large drain pipe medium 1 gas pipe medium 2 liquid pipe small electrical wiring i Drain hose j Insulation piece Small liquid pipe k Insulation piece Large gas pipe 3 About the units and options 3 1 About the indoor unit Use the system in the following tempera...

Page 5: ...l is less than 70 dBA CAUTION Appliance not accessible to the general public install it in a secured area protected from easy access This unit both indoor and outdoor is suitable for installation in a commercial and light industrial environment Spacing Mind the following requirements mm 1500 1500 2000 4000 1500 A B C b a d a c A Minimum distance to the wall B Minimum and maximum distance to the fl...

Page 6: ...ning is within the following limits Minimum 585 mm to be able to fit the unit Maximum 660 mm in case of installation with BYFQ60B and 595 mm in case of installation with BYFQ60C ensure enough overlapping between the decoration panel and the suspended ceiling If the ceiling opening is larger add extra ceiling material Make sure the unit and its hanger brackets suspension are centered within the cei...

Page 7: ...ipes Make sure to use drain pipes and T joints with the correct gauge for the operating capacity of the units 100 A mm a A 645 mm In case of installation with BYFQ60B 630 mm In case of installation with BYFQ60C a T joint To connect the drain piping to the indoor unit NOTICE Incorrect connection of the drain hose might cause leaks and damage the installation space and surroundings 1 Push the drain ...

Page 8: ... through the air discharge outlet and check for leaks see When electrical wiring is not finished yet 5 2 Connecting the refrigerant piping DANGER RISK OF BURNING 5 2 1 About connecting the refrigerant piping Before connecting the refrigerant piping Make sure the outdoor and indoor unit are mounted Typical workflow Connecting the refrigerant piping involves Connecting the refrigerant piping to the ...

Page 9: ...efrigerating system and prevents proper operation Set the nitrogen pressure to 20 kPa 0 2 bar just enough so it can be felt on the skin with a pressure reducing valve a b c d e f f a Refrigerant piping b Part to be brazed c Taping d Manual valve e Pressure reducing valve f Nitrogen Do NOT use anti oxidants when brazing pipe joints Residue can clog pipes and break equipment Do NOT use flux when bra...

Page 10: ...ectrical wiring on the indoor unit NOTICE Follow the wiring diagram delivered with the unit located at the inside of the service cover For instructions on how to connect the decoration panel and the sensor kit see the wiring instruction sheet delivered with the unit inside the accessory bag Make sure the electrical wiring does NOT obstruct proper reattachment of the service cover It is important t...

Page 11: ...eating operation LL2 Monitoring 12 12 22 3 01 Setup volume2 Monitoring 22 02 Setting Time to clean air filter This setting must correspond with the air contamination in the room It determines the interval at which the TIME TO CLEAN AIR FILTER notification is displayed on the user interface When using a wireless user interface you must also set the address see the installation manual of the user in...

Page 12: ...y earthed and the earth terminals are tightened The fuses or locally installed protection devices are installed according to this document and have not been bypassed The power supply voltage matches the voltage on the identification label of the unit There are NO loose connections or damaged electrical components in the switch box The insulation resistance of the compressor is OK There are NO dama...

Page 13: ...ply and outdoor unit between outdoor unit and indoor units between indoor unit and user interface The fuse on the outdoor or indoor unit PCB has blown E3 E4 or L8 The stop valves are closed The air inlet or air outlet is blocked E7 There is a missing phase in case of three phase power supply units Note Operation will be impossible Turn OFF the power recheck the wiring and switch two of the three e...

Page 14: ... OVERLOADPROTECTOR D V D DIODE Q M THERMOSWITCH DB DIODEBRIDGE R RESISTOR DS DIPSWITCH R T THERMISTOR E H HEATER RC RECEIVER F U FU FORCHARACTERISTICS REFERTOPCBINSIDEYOURUNIT FUSE S C LIMITSWITCH FG CONNECTOR FRAMEGROUND S L FLOATSWITCH H HARNESS S NPH PRESSURESENSOR HIGH H P LED V L PILOTLAMP LIGHTEMITTINGDIODE S NPL PRESSURESENSOR LOW HAP LIGHTEMITTINGDIODE SERVICEMONITORGREEN S PH HPS PRESSURE...

Page 15: ...e main functions of the system For more information about the user interface see the operation manual of the installed user interface 12 Operation 12 1 Operation range Use the system in the following temperature and humidity ranges for safe and effective operation For combination with R410A outdoor unit refer to the following table Outdoor units Cooling Heating RR71 125 Outdoor temperature 15 46 C...

Page 16: ...e indoor fan is automatically stopped The display of the user interface shows It may take some time before the fan starts This is not a malfunction 12 2 4 To operate the system 1 Press the operation mode selector button on the user interface several times and select the operation mode of your choice Cooling operation Heating operation Fan only operation 2 Press the ON OFF button on the user interf...

Page 17: ...ueeze it well and wipe the panel clean Wipe it with another dry cloth CAUTION Before accessing terminal devices make sure to interrupt all power supply NOTICE When cleaning the heat exchanger make sure to remove the switch box fan motor drain pump and float switch Water or detergent might deteriorate the insulation of electronic components and result in burnout of these components 13 1 Cleaning th...

Page 18: ...lean the air filter on page 17 and 13 1 3 To clean the air outlet and outside panels on page 18 Turn on the power at least 6 hours before operating the unit in order to ensure smoother operation As soon as the power is turned on the user interface display appears 13 3 Maintenance before a long stop period E g at the end of the season Let the indoor units run in fan only operation for about half a ...

Page 19: ...irely safe and non toxic R410A is a non combustible refrigerant and R32 is a mildly flammable refrigerant but they will generate a toxic gas when they accidentally leak into a room where combustible air from fan heaters gas cookers etc is present Always have qualified service personnel confirm that the point of leakage has been repaired or corrected before resuming operation 13 5 3 Recommended mai...

Page 20: ... indoor unit is not blocked by obstacles Remove any obstacles and make sure the air can flow freely Check if the air filter is not clogged see 13 1 1 To clean the air filter on page 17 Check the temperature setting Check the fan speed setting on your user interface Check for open doors or windows Close doors and windows to prevent wind from coming in Check if there are too many occupants in the ro...

Page 21: ... and contraction of plastic parts caused by temperature change make this noise 14 1 8 Symptom Noise of air conditioners Indoor unit outdoor unit A continuous low hissing sound is heard when the system is in cooling or defrost operation This is the sound of refrigerant gas flowing through both indoor and outdoor units A hissing sound which is heard at the start or immediately after stopping operati...