Important information regarding the 

refrigerant used 

This product contains fluorinated greenhouse gases covered 

by the Kyoto Protocol. 

Refrigerant type 

R410A 

GWP'1> value

1975 

'1> GWP = global warming potential

Periodical inspections for refrigerant leaks may be required 
depending on European or local legislation. Please contact 
your local dealer for more information. 

SAFETY PRECAUTIONS 

To gain full advantage of the air conditioner's functions 

and to avoid malfunction due to mishandling, 

we recommend  that  you  read  this  instruction  manual 

carefully before use. 

• This air conditioner is classified under "appliances not

accessible to the general public".

• Read the precautions  thoroughly to avoid misuse

of the equipment.

• The precautions described herein are classified as

WARNING and CAUTION. They both contain important

information regarding safety. Be sure to observe all

precautions without fail.

• There are two kinds of safety precaution and tips listed

in the following.

WARNING ........ 

Failure to follow these instructions

properly may result in personal injury or 
loss of life. 

CAUTION ......... 

Failure to observe these instructions

properly may result in property damage 
or personal injury,  which may be 
serious depending on the circumstances. 

• After reading, keep this manual in a convenient place

so that you can refer to it whenever necessary. If the

equipment is transferred to a new user, be sure also to

hand over the manual.

-& 

WARNING------------

• Consult your local dealer about installation work.

Doing the work yourself may result in water leakage,

electric shocks or fire hazards.

• Consult your local dealer regarding modification,

repair and maintenance of the air conditioner.

Improper workmanship may result in water leakage,

electric shocks or fire hazards.

• Beware of fire in case of refrigerant leakage.

If the air conditioner is not operating correctly, i.e. not

generating cool or warm air, refrigerant leakage could be

the cause. Consult your dealer for assistance.

The refrigerant within the air conditioner is safe and

normally does not leak. However, in the event of a leakage, 

contact with a naked burner,  heater or cooker may result in

generation of noxious gas.

Do not use the air conditioner until a qualified service

person confirms that the leakage has been repaired.

• Consult your local dealer regarding relocation and

reinstallation of the air conditioner.

Improper installation work may result in leakage, electric

shocks or fire hazards.

• Be aware that prolonged, direct exposure to

cool  air from the air conditioner, or to air that is too

cool can be harmful to your physical condition

and health.

• When the air conditioner is malfunctioning

(giving off a burning odour, etc.) turn off power to the

unit and contact your local dealer.

Continued operation under such circumstances may result
in a failure, electric shocks or fire hazards.

• Do not place objects, including rods, your fingers, etc.,

in the air inlet or outlet.

Injury may result due to contact with the air conditioner's

high speed fan blades.

• Consult your local dealer regarding what to

do in case of refrigerant leakage.

When the air conditioner is to be installed in a small room,
it is necessary to take proper measures so that the
amount of any leaked refrigerant does not exceed
the concentration limit in the event of a leakage.

Otherwise, this may lead to an accident due to
oxygen depletion.

• Contact professional personnel about attachment

of accessories and be sure to use only accessories

specified by the manufacturer.

If a defect results from your own workmanship, it

may result in water leaks, electric shock or fire.

• Be sure to use fuses with the correct ampere reading.

Do not use improper fuses, copper or other wires

as a substitute, as this may result in electric shock,fire,injury 

or damage to the unit.

• Be sure to earth the unit.

Do not earth the unit to a utility pipe, lighting conductor

or telephone earth lead. Imperfect earthing may result in
electric shocks or fire.
A high surge current from lightning or other sources may
cause damage to the air conditioner.

• Be sure to install an earth leakage breaker.

Failure to install an earth leakage breaker may

result in electric shocks or fire.

• Consult the dealer if the air conditioner submerges

owing to a natural disaster, such as a flood or typhoon.

Do not operate the air conditioner in that case,or otherwise

a malfunction, electric shock, or fire may result.

• Do not start or stop operating the air conditioner with

the power supply breaker turned ON or OFF.

Otherwise, fire or water leakage may result.

Furthermore, the fan will rotate abruptly if power failure

compensation is enabled, which may result in injury.

• Do not operate with the control panel lid open.

If water gets inside the panel, it may result in equipment

failure or electric shock.

• Do not place flammable sprays near the unit

as this can cause explosions.

English 

1

Summary of Contents for FDYQN180LCV1

Page 1: ...DAIKIN OPERATION MANUAL DUCTED Air Conditioners MODELS Ceiling mounted Duct type FDYQN180LCV1 FDYQN200LCV1...

Page 2: ...nual before using the air conditioner It will tell you how to use the unit properly and help you if any trouble occurs This manual explains about the indoor unit only Use it along with the operation m...

Page 3: ...ely 7 Power line 8 Grounding wire This wire releases electricity from the indoor unit to the ground in order to prevent electric shock or fire 9 Air filter inside filter chamber Sold separately 10 Suc...

Page 4: ...ion of the air conditioner Improper installation work may result in leakage electric shocks or fire hazards Be aware that prolonged direct exposure to cool air from the air conditioner or to air that...

Page 5: ...his will cause discoloration of the LCD display with resulting loss of readability English Do not wipe the controller panel with benzene or other organic solvent This will cause discoloration and or p...

Page 6: ...CE itWARNING Only a qualified person is allowed to perform maintenance except daily maintenance Before touching any of connection wirings be sure to turn off all power supply switches Do not use flamm...

Page 7: ...g so may result in discoloration or deformation Never dry the filter by direct firing Doing so may result in burning 3 Fix the air filter 4 Press the FILTER SIGN RESET BUTTON on the remote controller...

Page 8: ...170 Australia Phone 1300 3624 38 Daikin New Zealand 525 Great South Rd Penrose Auckland 6 www daikin com au DAIKIN INDUSTRIES LTD Head office Umeda Center Bldg 2 4 12 Nakazaki Nishi Kita ku Osaka 530...

Reviews: