background image

INSTALLATION SITE 

Regarding places for installation 

• Install the air conditioner in a well-ventilated  place

that Is free of obstructions

• Do not use the air conditioner in the following kinds

of places:

a. Where there is considerable use of mineral oil such as 

cutting oil 

b. Where there is much salt such as a beach area

c. Where there is sulphur gas such as in a hot-spring resort

d. Where there are considerable voltage fluctuations

such as a factory

e. Where there are motor vehicles or marine vessels

f. Where there is considerable atmospheric oil such

as in cooking areas

g. Where there are machines generating electromagnetic

radiation

h. Where the air contains acidic or alkaline steam or a vapour

• Protection against snow.  For details,  consult your dealer.

Regarding wiring 

• All wiring must be performed by an authorized

electrician.

Always consult your dealer about wiring.

Never do it by yourself.

• Only use the dedicated power supply circuit

provided for this air conditioner.

Also pay attention to operating noise. 

• Select the following kinds of location:

a. A place that can sufficiently withstand the

weight of the air conditioner with less running

noises and vibrations.

b. A place where warm airflow from the air outlet

of the outdoor unit and operating noise do not

cause a nuisance to neighbours.

• Be sure there are no obstructions near the air

outlet of the outdoor unit.

• Obstructions may result in poor performance

and increased operating noise.

If abnormal noise occur, ask your dealer for advise.

MAINTENANCE 

-it 

WARNING-------------

• Only a qualified person is allowed to perform

maintenance except daily maintenance.

• Before touching any of connection wirings, be sure to

turn off all power supply switches.

• Do not use flammable materials (e.g., hairspray or

insecticide) near the product.

Do not clean the product with organic solvents such

as paint thinner.

The use of organic solvents may cause crack damage to

the product, electric shocks, or fire.

• Contact professional personnel about attachment of

accessories and be sure to use only accessories

specified by the manufacturer.

If a defect results from your own workmanship, it may

result in water leaks, electric shock or fire.

• Consult your dealer regarding cleaning the inside of

the air conditioner.

Improper cleaning may cause breakage of plastic parts,

water leakage and other damage as well as electric

shocks.

-it 

CAUTION------------

• Before cleaning, be sure to stop unit operation, turn

the breaker off or remove the power cord.

Otherwise, an electric shock and injury may occur.

• Do not wash the air conditioner with water, as this may

result in electric shocks or fire.

• Watch your steps at the time of air filter cleaning or

inspection.

High-place work is required, to which utmost attention

must be paid.

If the scaffold is unstable, you may fall or topple down, thus

causing injury.

• Turn off the main power switch when the air

conditioner is not be used for prolonged periods.

When the main power switch is left on, some electric

power (watts) is still consumed even if the air conditioner

is not operating. Therefore, switch off the main power

switch to save energy. When resuming operation,

to ensure smooth running, turn on the main power

switch 6 hours before operating the air conditioner again.

English 

Summary of Contents for FDYQN180LCV1

Page 1: ...DAIKIN OPERATION MANUAL DUCTED Air Conditioners MODELS Ceiling mounted Duct type FDYQN180LCV1 FDYQN200LCV1...

Page 2: ...nual before using the air conditioner It will tell you how to use the unit properly and help you if any trouble occurs This manual explains about the indoor unit only Use it along with the operation m...

Page 3: ...ely 7 Power line 8 Grounding wire This wire releases electricity from the indoor unit to the ground in order to prevent electric shock or fire 9 Air filter inside filter chamber Sold separately 10 Suc...

Page 4: ...ion of the air conditioner Improper installation work may result in leakage electric shocks or fire hazards Be aware that prolonged direct exposure to cool air from the air conditioner or to air that...

Page 5: ...his will cause discoloration of the LCD display with resulting loss of readability English Do not wipe the controller panel with benzene or other organic solvent This will cause discoloration and or p...

Page 6: ...CE itWARNING Only a qualified person is allowed to perform maintenance except daily maintenance Before touching any of connection wirings be sure to turn off all power supply switches Do not use flamm...

Page 7: ...g so may result in discoloration or deformation Never dry the filter by direct firing Doing so may result in burning 3 Fix the air filter 4 Press the FILTER SIGN RESET BUTTON on the remote controller...

Page 8: ...170 Australia Phone 1300 3624 38 Daikin New Zealand 525 Great South Rd Penrose Auckland 6 www daikin com au DAIKIN INDUSTRIES LTD Head office Umeda Center Bldg 2 4 12 Nakazaki Nishi Kita ku Osaka 530...

Reviews: