background image

 

 

 

Installation and operation manual

 

1

 

FDYMP71~125L7V1

Split System air conditioners

4PW14036-1B

 

C

 

ONTENTS

 

Page

 

Installing the unit ...................................................... 1

 

Before installation.............................................................................. 1

Selecting installation site................................................................... 2

Preparations before installation......................................................... 2

Indoor unit installation ....................................................................... 3

Refrigerant piping work ..................................................................... 3

Drain piping work .............................................................................. 3

Electric wiring work ........................................................................... 4

Wiring example and how to set the remote controller ....................... 4

Wiring example ................................................................................. 4

Field setting....................................................................................... 5

Test operation.................................................................................... 5

 

Operating the unit ..................................................... 6

 

Names and functions of parts ........................................................... 6

Operation range ................................................................................ 6

Operation procedure ......................................................................... 6

Optimum operation............................................................................ 6

Not a malfunction of the air conditioner............................................. 7

Troubleshooting ................................................................................. 7

Maintenance...................................................................................... 8

 

I

 

NSTALLING

 

 

 

THE

 

 

 

UNIT

 

B

 

EFORE

 

 

 

INSTALLATION

 

 

Leave the unit inside its packaging until you reach the
installation site. Where unpacking is unavoidable, use a sling of
soft material or protective plates together with a rope when
lifting, this to avoid damage or scratches to the unit.

 

 

Refer to the installation manual of the outdoor unit for items not
described in this manual.

 

Precautions

 

 

Do not install or operate the unit in rooms mentioned below.

Places with mineral oil, or filled with oil vapour or spray like in
kitchens. (Plastic parts may deteriorate.)

Where corrosive gas like sulphurous gas exists. (Copper
tubing and brazed spots may corrode.)

Where volatile flammable gas like thinner or gasoline is used.

Where machines generating electromagnetic waves can be
found. (Control system may malfunction.)

Where the air contains high levels of salt such as air near the
ocean and where voltage fluctuates a lot (e.g. in factories).
Also in vehicles or vessels.

 

 

Do not install accessories on the casing directly. Drilling holes in
the casing may damage electrical wires and consequently cause
fire.

 

Optional accessories

 

Refer to catalogues and technical literature for selecting the remote
controller, and install it in an appropriate place.

 

FDYMP71L7V1
FDYMP100L7V1
FDYMP125L7V1

 

Split System air conditioners

 

Installation and

operation manual

 

THANK YOU FOR PURCHASING THIS DAIKIN AIR
CONDITIONER. CAREFULLY READ THE CHAPTER

"OPERATING THE UNIT" ON PAGE 6

  BEFORE USING

THE AIR CONDITIONER. IT WILL TELL YOU HOW TO
USE THE UNIT PROPERLY AND HELP YOU IF ANY
TROUBLE OCCURS. AFTER READING THE MANUAL,
FILE IT AWAY FOR FUTURE REFERENCE.

 

READ THESE INSTRUCTIONS CAREFULLY BEFORE
INSTALLATION.

IMPROPER INSTALLATION OR ATTACHMENT OF
EQUIPMENT OR ACCESSORIES COULD RESULT IN
ELECTRIC SHOCK, SHORT-CIRCUIT, LEAKS, FIRE OR
OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY
TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE
SPECIFICALLY DESIGNED FOR USE WITH THE
EQUIPMENT AND HAVE THEM INSTALLED BY A
PROFESSIONAL.

IF UNCERTAINTY ARISES ABOUT THE INSTALLATION
PROCEDURES OR USE, ALWAYS CONTACT YOUR
DAIKIN DEALER FOR ADVICE AND INFORMATION.

Summary of Contents for FDYMP100L7V1

Page 1: ...INSTALLATION AND OPERATION MANUAL FDYMP71L7V1 FDYMP100L7V1 FDYMP125L7V1 Split System air conditioners ...

Page 2: ... 25 10 43 5 46 18 35 12 25 18 35 12 25 RP71 125 RYP71 125 RYEP71 125 RYP71 125 RYEP71 125 1 2 1 2 3 1 2 3 1 2 3 4 5 P1 P2 6 1 2 3 1 2 3 1 2 3 4 5 P1 P2 1 2 3 1 2 3 1 2 3 4 5 P1 P2 P1 P2 M S S 1 X40A 1 2 3 1 2 3 1 2 3 4 5 P1 P2 P1 P2 P1 P2 6 6 M 3 8 9 10 2 1 6 4 7 1 2 3 P1 P2 7 6 11 8 1 10 9 4 3 2 5 5 6 C DB C WB C DB C WB C DB C WB C DB C WB C DB C WB C DB C DB 1 2 3 4 9 8 7 5 6 10 11 12 15 14 13 ...

Page 3: ...givande dokument under förutsättning att användning sker i överensstämmelse med våra instruktioner respektive utstyr er i overensstemmelse med følgende standard er eller andre normgivende dokument er under forutssetning av at disse brukes i henhold til våre instrukser vastaavat seuraavien standardien ja muiden ohjeellisten dokumenttien vaatimuksia edellyttäen että niitä käytetään ohjeidemme mukais...

Page 4: ...here volatile flammable gas like thinner or gasoline is used Where machines generating electromagnetic waves can be found Control system may malfunction Where the air contains high levels of salt such as air near the ocean and where voltage fluctuates a lot e g in factories Also in vehicles or vessels Do not install accessories on the casing directly Drilling holes in the casing may damage electri...

Page 5: ...ee figure 6 For other installation than standard installation contact your Daikin dealer for details 2 The fan speed for this indoor unit is preset to provide high external static pressure If lower external static pressure is required reset the external static pressure by changing the initial setting from the remote controller Refer to Setting of static pressure on page 5 3 Install the suspension ...

Page 6: ...nsulate it DRAIN PIPING WORK 1 Install the drain pipes Keep piping as short as possible and slope it downwards so that air may not remain trapped inside the pipe Keep pipe size equal to or greater than that of the connecting pipe For connection to the drain socket use a flexible hose field supply and clamp it firmly This to avoid leaks due to operating vibration of the unit After clamping isolate ...

Page 7: ...he remote controller supplied with the remote controller 5 Never connect the power supply wiring to the terminal board for transmission wiring This mistake could damage the entire system 6 Use only specified wires and tightly connect wires to the terminals Be careful that wires do not place external stress on the terminals Keep wiring in neat order so that they do not obstruct other equipment such...

Page 8: ...ff Table 4 TEST OPERATION Refer to the section of For the following items take special care during construction and check after installation is finished on page 2 After finishing the construction of refrigerant piping drain piping and electric wiring conduct test operation accordingly to protect the unit 1 Open the gas side stop valve 2 Open the liquid side stop valve 3 Electrify crank case heater...

Page 9: ... when not using for long periods of time Electricity is consumed as long as the switch is on Turn off the main power supply switch in order to save energy Turn on the main power supply switch 6 hours before restarting operation in order to ensure smooth operation Refer to Maintenance on page 8 When the display shows TIME TO CLEAN AIR FILTER have a qualified service person to clean the filters Refe...

Page 10: ...s this noise Dust from the units Dust may blow out from the unit after starting operation from long resting time Dust absorbed by the unit blows out The units give off odours The unit absorbs the smell of rooms furniture cigarettes etc and then emits them The liquid crystal display of the remote controller shows Happens immediately after the main power supply switch is turned on Shows that the rem...

Page 11: ...Remove any obstacle Check if the earth is connected Clean the air filter After cleaning the air filter make sure to attach it Turn on the main power supply switch The control panel display lights when the power is turned on To protect the unit turn on the main power switch at least 6 hours before operation What to do when stopping the system for a long period Turn on FAN OPERATION for a half day a...

Page 12: ...Zandvoordestraat 300 B 8400 Oostende Belgium 4PWEN14036 1B ...

Reviews: