IMPORTANT:
*
These values are for information only, they should be checked and selected to comply with the local and/or national
codes and regulations. They are also subjected to the type of installation and size of conductors.
Heat Pump Units
Power Supply Cable
Terminal Strip
Indoor Unit
Terminal Strip
Outdoor Unit
FDYM90CV1M/FDYB90CV1M - RY90CV1M
FDYM100CV1M - RY100CV1M
FDYM125CV1M/FDYB125CV1M - RY125CV1M
Outdoor Coil Sensor
There must be a all pole switch
with a minimum 3 mm contact gap
and fuse / circuit breaker as
recommended in the fixed installation
circuits.
!
N
OF
4WV
COMP
OF
4WV
L
A
L
N
L
N
There must be a all pole switch
with a minimum 3 mm contact gap and
fuse / circuit breaker as recommended
in the fixed installation circuits.
!
FDYM90CV1M/FDYB90CV1M - RY90CY1M
FDYM125CV1M/FDYB125CV1M - RY125CY1M
FDYM140CV1M/FDYB140CV1M - RY140CY1M
FDYM160CV1M/FDYB160CV1M - RY160CY1M
Power Supply Cable
Terminal Strip
Indoor Unit
Terminal Strip
Outdoor Unit
Outdoor Coil Sensor
OF
COMP
4WV
L
A
N
N
OF
A
4WV
L
N
COMP
T
S
R
!
!
!
COMP
!
!
!
!
N
A
Indoor unit
FDYM90CV1M FDYM125CV1M FDYM140CV1M FDYM160CV1M
FDYB90CV1M FDYB125CV1M FDYB140CV1M FDYB160CV1M
Outdoor unit
RY90CY1M RY125CY1M RY140CY1M RY160CY1M
Voltage range
380V-415V /3Ph /50Hz + N +
!
Recommended fuse*
A
10
10 16
16
Power supply cable size*
mm
2
1.5
1.5 2.5
2.5
Number of conductors
5
5
5
5
Interconnection cable size*
mm
2
1.5
1.5 1.5
1.5
Number of conductors
7
7
7
7