background image

8 Troubleshooting

User reference guide

7

FDXM25~60F3V1B(9)
Split system air conditioners
4P543324-1 – 2018.07

rear suction

bottom suction

2

1

2

1

2

Clean the air filter

. Use a vacuum cleaner or wash with water.

If  the  air  filter  is  very  dirty,  use  a  soft  brush  and  neutral
detergent.

3

Dry the air filter in the shadow.

4

Reattach  the  air  filter.

  Hook  the  filter  behind  the  flap  and

attach  the  filter  to  the  main  unit  while  pushing  down  on  the
hooks.

rear suction

bottom suction

2

1

2

1

5

Turn ON the power.

6

Press the 

FILTER SIGN RESET

 button.

Result: 

The 

TIME  TO  CLEAN  AIR  FILTER

  notification  disappears

from the user interface.

7.4

Maintenance before a long stop
period

E.g., at the end of the season.

▪ Let the indoor units run in fan only operation for about half a day in

order to dry the interior of the units.

▪ Turn  off  the  power.  The  user  interface  display  disappears.  When

the  main  power  is  turned  on,  the  air  conditioner  will  use  some
power, even if it is not operating.

▪ Clean air filters and casings of indoor units. Contact your installer

or  maintenance  person  to  clean  air  filters  and  casings  of  the
indoor  unit.  Maintenance  tips  and  procedures  for  cleaning  are
provided in the installation/operation manuals of dedicated indoor
units.  Make  sure  to  install  cleaned  air  filters  back  in  the  same
position.

▪ Remove the batteries from the user interface.

7.5

Maintenance after a long stop
period

E.g., at the beginning of the season.

▪ Check  and  remove  everything  that  might  be  blocking  inlet  and

outlet vents of indoor units and outdoor units.

▪ Check if the earth is connected properly.

▪ Check if there is somewhere a broken wire. Contact your dealer in

case of problems.

▪ Clean air filters and casings of indoor units. Contact your installer

or  maintenance  person  to  clean  air  filters  and  casings  of  the
indoor  unit.  Maintenance  tips  and  procedures  for  cleaning  are
provided in the installation/operation manuals of dedicated indoor
units.  Make  sure  to  install  cleaned  air  filters  back  in  the  same
position.

▪ Turn  on  the  power  at  least  6  hours  before  operating  the  unit  in

order  to  ensure  smoother  operation.  As  soon  as  the  power  is
turned on, the user interface display appears.

8

Troubleshooting

If one of the following malfunctions occur, take the measures shown
below and contact your dealer.

WARNING

Stop  operation  and  shut  off  the  power  if  anything
unusual occurs (burning smells etc.).

Leaving  the  unit  running  under  such  circumstances  may
cause breakage, electric shock or fire. Contact your dealer.

The system MUST be repaired by a qualified service person.

If  the  system  does  NOT  properly  operate  except  for  the  above
mentioned cases and none of the above mentioned malfunctions is
evident,  investigate  the  system  according  to  the  following
procedures.

Malfunction

Measure

If the system does not
operate at all.

▪ Check  if  there  is  no  power  failure.  Wait

until  power  is  restored.  If  power  failure
occurs  during  operation,  the  system
automatically  restarts  immediately  after
power is restored.

▪ Check if no fuse has blown or breaker is

activated.  Change  the  fuse  or  reset  the
breaker if necessary.

▪ Are batteries set in the remote controller?

▪ Is the timer setting correct?

Summary of Contents for FDXM25F3V1B9

Page 1: ...reference guide Split system air conditioners English User reference guide Split system air conditioners FDXM25F3V1B FDXM35F3V1B FDXM50F3V1B FDXM60F3V1B FDXM25F3V1B9 FDXM35F3V1B9 FDXM50F3V1B9 FDXM60F3...

Page 2: ...the installation manual and the installer reference guide MUST be performed by an authorised installer 1 1 1 Meaning of warnings and symbols DANGER Indicates a situation that results in death or serio...

Page 3: ...nit User reference guide Detailed step by step instructions and background information for basic and advanced usage Format Digital files on http www daikineurope com support and manuals product inform...

Page 4: ...he internal parts of the controller Do NOT remove the front panel Some parts inside are dangerous to touch and appliance problems may happen For checking and adjusting the internal parts contact your...

Page 5: ...to avoid any quality deterioration do NOT use the unit for cooling precision instruments food plants animals or works of art CAUTION Do NOT operate the system when using a room fumigation type insect...

Page 6: ...ROCUTION To clean the air conditioner or air filter be sure to stop operation and turn all power supplies off Otherwise an electric shock and injury may result WARNING To prevent electric shocks or fi...

Page 7: ...g inlet and outlet vents of indoor units and outdoor units Check if the earth is connected properly Check if there is somewhere a broken wire Contact your dealer in case of problems Clean air filters...

Page 8: ...The air conditioner does not restart immediately when the temperature setting button is returned to its former position after pushing It does not restart immediately because one of its safety devices...

Page 9: ...nal European national and local directives laws regulations and or codes that are relevant and applicable for a certain product or domain Service company Qualified company which can perform or coordin...

Page 10: ......

Page 11: ......

Page 12: ...4P543324 1 2018 07 Copyright 2018 Daikin...

Reviews: