background image

Table of Contents

User reference guide

2

FDXM25~60F3V1B(9)

Split system air conditioners

4P543324-1 – 2018.07

Table of Contents

1 General safety precautions

2

1.1

About the documentation ..........................................................

2

1.1.1

Meaning of warnings and symbols..............................

2

1.2

For the user ...............................................................................

2

2 About this document

3

2.1

User reference guide at a glance ..............................................

3

3 About the system

3

3.1

Components ..............................................................................

3

3.2

User interface ............................................................................

4

4 Before operation

4

5 Operation

4

5.1

Operation range ........................................................................

4

6 Energy saving and optimum operation

5

7 Maintenance and service

6

7.1

Overview: Maintenance and service .........................................

6

7.2

To clean the drain pan...............................................................

6

7.3

Cleaning the air filter, suction grille, air outlet and outside
panels  .......................................................................................

6

7.3.1

To clean the air outlet and outside panels ..................

6

7.3.2

To clean the air filter ...................................................

6

7.4

Maintenance before a long stop period .....................................

7

7.5

Maintenance after a long stop period ........................................

7

8 Troubleshooting

7

8.1

Symptoms that are NOT system malfunctions ..........................

8

8.1.1

Symptom: The system does not operate ....................

8

8.1.2

Symptom: White mist comes out of a unit (Indoor
unit) .............................................................................

8

8.1.3

Symptom: Dust comes out of the unit .........................

8

8.1.4

Symptom: The units can give off odours.....................

8

8.1.5

Symptom: The operation stopped suddenly
(Operation lamp is on) ................................................

8

8.1.6

Symptom: The outdoor fan rotates while the air
conditioner is not in operation .....................................

8

8.1.7

Symptom: The heating operation stops suddenly and
a flowing sound is heard .............................................

8

9 Disposal

9

10 Glossary

9

1

General safety precautions

1.1

About the documentation

▪ The  original  documentation  is  written  in  English.  All  other

languages are translations.

▪ The precautions described in this document cover very important

topics, follow them carefully.

▪ The  installation  of  the  system,  and  all  activities  described  in  the

installation  manual  and  the  installer  reference  guide  MUST  be
performed by an authorised installer.

1.1.1

Meaning of warnings and symbols

DANGER

Indicates a situation that results in death or serious injury.

DANGER: RISK OF ELECTROCUTION

Indicates a situation that could result in electrocution.

DANGER: RISK OF BURNING

Indicates a situation that could result in burning because of
extreme hot or cold temperatures.

DANGER: RISK OF EXPLOSION

Indicates a situation that could result in explosion.

WARNING

Indicates  a  situation  that  could  result  in  death  or  serious
injury.

WARNING: FLAMMABLE MATERIAL

CAUTION

Indicates a situation that could result in minor or moderate
injury.

NOTICE

Indicates  a  situation  that  could  result  in  equipment  or
property damage.

INFORMATION

Indicates useful tips or additional information.

Symbol

Explanation

Before installation, read the installation and
operation manual, and the wiring instruction sheet.

Before performing maintenance and service tasks,
read the service manual.

For more information, see the installer and user
reference guide.

1.2

For the user

▪ If you are NOT sure how to operate the unit, contact your installer.

▪ This  appliance  can  be  used  by  children  aged  from  8  years  and

above  and  persons  with  reduced  physical,  sensory  or  mental
capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in
a  safe  way  and  understand  the  hazards  involved.  Children  shall
NOT  play  with  the  appliance.  Cleaning  and  user  maintenance
shall NOT be made by children without supervision.

WARNING

To prevent electric shocks or fire:

▪ Do NOT rinse the unit.

▪ Do NOT operate the unit with wet hands.

▪ Do NOT place any objects containing water on the unit.

NOTICE

▪ Do  NOT  place  any  objects  or  equipment  on  top  of  the

unit.

▪ Do NOT sit, climb or stand on the unit.

Summary of Contents for FDXM25F3V1B9

Page 1: ...reference guide Split system air conditioners English User reference guide Split system air conditioners FDXM25F3V1B FDXM35F3V1B FDXM50F3V1B FDXM60F3V1B FDXM25F3V1B9 FDXM35F3V1B9 FDXM50F3V1B9 FDXM60F3...

Page 2: ...the installation manual and the installer reference guide MUST be performed by an authorised installer 1 1 1 Meaning of warnings and symbols DANGER Indicates a situation that results in death or serio...

Page 3: ...nit User reference guide Detailed step by step instructions and background information for basic and advanced usage Format Digital files on http www daikineurope com support and manuals product inform...

Page 4: ...he internal parts of the controller Do NOT remove the front panel Some parts inside are dangerous to touch and appliance problems may happen For checking and adjusting the internal parts contact your...

Page 5: ...to avoid any quality deterioration do NOT use the unit for cooling precision instruments food plants animals or works of art CAUTION Do NOT operate the system when using a room fumigation type insect...

Page 6: ...ROCUTION To clean the air conditioner or air filter be sure to stop operation and turn all power supplies off Otherwise an electric shock and injury may result WARNING To prevent electric shocks or fi...

Page 7: ...g inlet and outlet vents of indoor units and outdoor units Check if the earth is connected properly Check if there is somewhere a broken wire Contact your dealer in case of problems Clean air filters...

Page 8: ...The air conditioner does not restart immediately when the temperature setting button is returned to its former position after pushing It does not restart immediately because one of its safety devices...

Page 9: ...nal European national and local directives laws regulations and or codes that are relevant and applicable for a certain product or domain Service company Qualified company which can perform or coordin...

Page 10: ......

Page 11: ......

Page 12: ...4P543324 1 2018 07 Copyright 2018 Daikin...

Reviews: