4 Before operation

User reference guide

4

FDXM25~60F3V1B(9)

Split system air conditioners

4P543324-1 – 2018.07

b

c

a

e

d

f

h

a

Indoor unit

b

Outdoor unit

c

User interface

d

Air inlet

e

Air outlet

f

Refrigerant piping and electric wiring

g

Drain pipe

h

Earth wire to ground outdoor unit to prevent electric
shocks.

CAUTION

Do  NOT  insert  fingers,  rods  or  other  objects  into  the  air
inlet  or  outlet.  Do  NOT  remove  the  fan  guard.  When  the
fan is rotating at high speed, it will cause injury.

CAUTION

▪ NEVER touch the internal parts of the controller.

▪ Do NOT remove the front panel. Some parts inside are

dangerous  to  touch  and  appliance  problems  may
happen.  For  checking  and  adjusting  the  internal  parts,
contact your dealer.

NOTICE

Do  not  wipe  the  controller  operation  panel  with  benzine,
thinner,  chemical  dust  cloth,  etc.  The  panel  may  get
discoloured  or  the  coating  peeled  off.  If  it  is  heavily  dirty,
soak  a  cloth  in  water-diluted  neutral  detergent,  squeeze  it
well  and  wipe  the  panel  clean.  Wipe  it  with  another  dry
cloth.

NOTICE

Never  press  the  button  of  the  user  interface  with  a  hard,
pointed object. The user interface may be damaged.

NOTICE

Never pull or twist the electric wire of the user interface. It
may cause the unit to malfunction.

3.2

User interface

CAUTION

▪ NEVER touch the internal parts of the controller.

▪ Do NOT remove the front panel. Some parts inside are

dangerous  to  touch  and  appliance  problems  may
happen.  For  checking  and  adjusting  the  internal  parts,
contact your dealer.

This  operation  manual  will  give  a  non-exhaustive  overview  of  the
main functions of the system.

Refer  to  the  operation  manual  of  the  user  interface  for  information
about the display and the buttons of the user interface.

4

Before operation

WARNING

This unit contains electrical and hot parts.

WARNING

Before operating the unit, be sure the installation has been
carried out correctly by an installer.

CAUTION

It is not good for your health to expose your body to the air
flow for a long time.

CAUTION

To  avoid  oxygen  deficiency,  ventilate  the  room  sufficiently
if equipment with burner is used together with the system.

CAUTION

Do  NOT  operate  the  system  when  using  a  room
fumigation-type  insecticide.  Chemicals  could  collect  in  the
unit,  and  endanger  the  health  of  people  who  are
hypersensitive to chemicals.

NOTICE

Be  sure  to  turn  on  the  power  6  hours  before  operation  in
order  to  have  power  running  to  the  crankcase  heater  and
to protect the compressor.

5

Operation

5.1

Operation range

For combination with R410A outdoor unit, refer to the following table:

Outdoor units

Cooling

Heating

RR71~125

–15~46°C DB

18~37°C DB

12~28°C WB

RQ71~125

–5~46°C DB

–9~21°C DB

–10~15°C WB

18~37°C DB

12~28°C WB

10~27°C DB

RXS25~60

–10~46°C DB

–15~24°C DB

–16~18°C WB

18~32°C DB

10~30°C DB

Summary of Contents for FDXM25F3V1B9

Page 1: ...reference guide Split system air conditioners English User reference guide Split system air conditioners FDXM25F3V1B FDXM35F3V1B FDXM50F3V1B FDXM60F3V1B FDXM25F3V1B9 FDXM35F3V1B9 FDXM50F3V1B9 FDXM60F3...

Page 2: ...the installation manual and the installer reference guide MUST be performed by an authorised installer 1 1 1 Meaning of warnings and symbols DANGER Indicates a situation that results in death or serio...

Page 3: ...nit User reference guide Detailed step by step instructions and background information for basic and advanced usage Format Digital files on http www daikineurope com support and manuals product inform...

Page 4: ...he internal parts of the controller Do NOT remove the front panel Some parts inside are dangerous to touch and appliance problems may happen For checking and adjusting the internal parts contact your...

Page 5: ...to avoid any quality deterioration do NOT use the unit for cooling precision instruments food plants animals or works of art CAUTION Do NOT operate the system when using a room fumigation type insect...

Page 6: ...ROCUTION To clean the air conditioner or air filter be sure to stop operation and turn all power supplies off Otherwise an electric shock and injury may result WARNING To prevent electric shocks or fi...

Page 7: ...g inlet and outlet vents of indoor units and outdoor units Check if the earth is connected properly Check if there is somewhere a broken wire Contact your dealer in case of problems Clean air filters...

Page 8: ...The air conditioner does not restart immediately when the temperature setting button is returned to its former position after pushing It does not restart immediately because one of its safety devices...

Page 9: ...nal European national and local directives laws regulations and or codes that are relevant and applicable for a certain product or domain Service company Qualified company which can perform or coordin...

Page 10: ......

Page 11: ......

Page 12: ...4P543324 1 2018 07 Copyright 2018 Daikin...

Reviews: