READ BEFORE OPERATION

Safety precautions

• Keep this manual where the operator can easily find them.

• Read this manual attentively before starting up the unit.

• For safety reason the operator must read the following cautions carefully.

• This manual classifies precautions into WARNING and CAUTION. Be sure to follow all precautions below: they are 

all important for ensuring safety.

• The sound power is less than 70dB(A).

WARNING

In order to avoid fire, explosion or injury, do not operate the unit when harmful, among which flammable 

or corrosive gases, are detected near the unit.

• It is not good for health to expose your body to the air flow for a long time.
• Do not put a finger, a rod or other objects into the air outlet or inlet. As the fan is rotating at a high speed, 

it will cause injury.

• Do not attempt to repair, relocate, modify or reinstall the air conditioner by yourself. Incorrect work will cause 

electric shocks, fire etc. 

For repairs and reinstallation, consult your Daikin dealer for advice and information.

• The refrigerant used in the air conditioner is safe. Although leaks should not occur, if for some reason 

any refrigerant happens to leak into the room, make sure it does not come in contact with any flame as 

of gas heaters, kerosene heaters or gas range.

• If the air conditioner is not cooling (heating) properly, the refrigerant may be leaking, so call your dealer.

When carrying out repairs accompanying adding refrigerant, check the content of the repairs with our 

service staff.

• Do not attempt to install the air conditioner by your self. Incorrect work will result in water leakage, electric shocks 

or fire. For installation, consult the dealer or a qualified technician.

• In order to avoid electric shock, fire or injury, if you detect any abnormally such as smell of fire, stop the operation 

and turn off the breaker. And call your dealer for instructions.

• Depending on the environment, an earth leakage breaker must be installed. Lack of an earth leakage breaker may 

result in electric shocks or fire.

• The air conditioner must be earthed. Incomplete earthing may result in electric shocks. Do not connect 

the earth line to a gas pipe, water pipe, lightning rod, or a telephone earth line.

WARNING

If you do not follow these instructions exactly, the unit may 

cause property damage, personal injury or loss of life.

CAUTION

If you do not follow these instructions exactly, the unit may 

cause minor or moderate property damage or personal injury.

Never do.

Be sure to follow the instructions.

Be sure to earth the air conditioner.

Never cause the air conditioner (including the remote 

controller) to get wet.

Never touch the air conditioner (including the remote 

controller) with a wet hand.

Read the precautions in this manual 
carefully before operating the unit.

This appliance is filled with R32.

Summary of Contents for FDXM25F2V1B

Page 1: ...FDXM25F2V1B FDXM50F2V1B FDXM35F2V1B FDXM60F2V1B DAIKIN ROOM AIR CONDITIONER Operation Manual...

Page 2: ...OPERATION Safety precautions 2 Names of parts 4 CARE Care and Cleaning 6 TROUBLE SHOOTING Troubleshooting 8 The original instructions are written in English All other languages are translations of the...

Page 3: ...cooling heating properly the refrigerant may be leaking so call your dealer When carrying out repairs accompanying adding refrigerant check the content of the repairs with our service staff Do not at...

Page 4: ...from the one as specified It may cause trouble or fire Arrange the drain hose to ensure smooth drainage Incomplete draining may cause wetting of the building furniture etc Do not place things that mus...

Page 5: ...Names of parts Indoor Unit OPTIONAL ACCESSORIES This indoor unit at least requires one of the remote controllers Refer to the operation manual delivered with remote controller 1 3 4 2 Remote controlle...

Page 6: ...o use the air conditioner for a long period for example in spring or autumn turn the breaker OFF Use the air conditioner in the following conditions Operation outside this humidity or temperature rang...

Page 7: ...fter cleaning dry them in the shade 3 Replacing the air filter Rear suction Hook the filter behind the flap situated at the top of the unit and push the other side gently over the bends 2 bends for 25...

Page 8: ...ot operate the air conditioner without filters this to avoid dust accumulation inside the unit Do not remove the air filter except when cleaning Unnecessary handling may damage the filter Do not use g...

Page 9: ...ditioner is in defrost operation In COOL or DRY mode Moisture in the air condenses into water on the cool surface of outdoor unit piping and drips Mists come out of the indoor unit This happens when t...

Page 10: ...the indoor and the outdoor units Clean the air filters or take all obstacles away and turn the breaker OFF Then turn it ON again and try operating the air conditioner with the remote controller If the...

Page 11: ...will help to prevent potential negative consequences for environment and human health Please contact the installer or local authority for more information Dismantling of the unit treatment of the ref...

Page 12: ...Copyright 2015 Daikin 3P417670 1A 2015 09...