Cooling only
STANDARD OPERATING CONDITIONS
a::i
0
<:__)
0
...___..
48
46
40
• 30
=-
E
CJ.)
I-
,:_
C)
=
20
:::, 19
=
c=i
1 0
NOTES:
10
1
2730 35
Indoor TemP.(
°
COB)
The graph is based on the fol lowing conditions:
Equivalent piping length: 7.5m
Level difference
Om
Air Flow Rate
High
AUTO RANDOM RE-START FUNCTION
If there is a power cut when the unit is operating, it will automatically resume the same operating mode when the
power is restored. (Applicable only to units with this feature)
SERVICE AND MAINTENANCE
Service Parts
Maintenance Procedures
Period
Indoor air filter
1. Remove any dust adhering to the filter by using a vacuum
cleaner or wash in lukewarm water (below 40
°
C) with a
neutral cleaning detergent.
At least once every 2 weeks.
2. Rinse the filter well and dry before placing it back onto
the unit.
More frequently if necessary.
3.
Do not use gasoline, volatile substances or chemicals to
clean the filter.
Indoor unit
1. Clean any dirt or dust on the grille or panel by wiping it
with a soft cloth soaked in lukewarm water (below 40
°
C)
At least once every 2 weeks.
and a neutral detergent solution.
2. Do not use gasoline, volatile substances or chemicals to
More frequently if necessary.
clean the indoor unit.
21