English
19
5.12 Blow Function Setting
Blow function: After the unit is turned off, water in evaporator of indoor unit will be automatically evaporated to
avoid mildew.
In cooling and dry mode, press
Function
button till the unit enters dry function,
BLOW
blinking,
and then press
Enter/Cancel
button to turn on this function.
In blow mode, press
Function
button till the unit enters blow function and then press
Enter/
Cancel
button to cancel this function.
Blow function setting is shown in Fig.5.12
Press “Function” button
into blow function
Press “Enter/Cancel” button
to turn on blow function
Press “Enter/Cancel” button
to turn off blow function
Press “Function” button
into blow function
Turn on the unit, without
turning on blow function
5.12 Blow function setting
Fig.
Note:
After setting blow function, turn off the unit by pressing
1.
On/Off
button or remote controller, indoor fan
will run at low fan speed for 10 min. (
BLOW
shows). Meanwhile, if blow function is canceled indoor fan
will be turned off directly.
There is no BLOW function in fan or heating mode.
2.