1-8
NOTE
Install the front frame panel
fi
rmly to prevent cool air leakage which will cause condensation and water dripping.
Cover Lock Grille (The moving part protection for user direct touching)
Cover lock grille must be installed as the figure below.
If the unit need to be service, steps below shall be followed:
Con
fi
rm that the unit had been switched off before servicing the unit.
Use screwdriver to unlock the screw on the cover lock grille.
Remove the cover lock grille and open the intake grille for the service purpose.
Install the intake grille and screw the cover lock grille after service and make sure the unit is proper install.
1.
2.
3.
4.
Frame
Intake Grille
Cover Lock Grille
(2pcs)
Screw 4 x 6
(2pcs)
Indoor Unit
Cool
Air
Ceiling Board
Panel
Air Leak
Cool
Air
Air Leak
Ceiling Board
Panel