• Split Sky Air • Indoor Units

12

• Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB

7

Wiring diagram

7

 - 1

Wiring diagram

FCQH71-140D8VEB

3TW32426-1

NOTES

In case of using a central remote control, connect it to the unit in accordance with th attached installation manual.

X

2

4A, X33A and X335A are connected when the o

p

tional accessories are being used.

Remote control model 

v

aries according to the combination system, confi rm engineering data and catalogs, etc. before connecting.

C

onfi rm the method of setting the selector switch (SS1, SS

2

) by installation manual and engineering data, etc.

In case of self cleaning 

p

anel follow the self cleaning 

p

anel installation instruction.

1.

2

.

3.

4.

5.

Indoor unit

(master)

Indoor unit

Receiver display unit (attached to wireless remote controller)

A1

P

P

rinted circuit board

A3

P

P

rinted circuit board

A

2P

P

rinted circuit board (Humidity sensor unit)

A4

P

P

rinted circuit board

HA

P

Light emitting diode (Ser

v

ice monitor green)

BS1

P

ush button (On/off)

K

P

R

Magnetic relay (M1

P

)

H1

P

Light emitting diode (On-red)

M1F

Motor (Indoor fan)

H

2P

Light emitting diode (Timer-green)

M1

P

Motor (Drain 

p

um

p

)

H3

P

Light emitting diode (Filter sign-red)

M1S

Motor (Swing fl a

p

)

H4

P

Light emitting diode (Defrost - orange)

P

S

P

ower su

pp

ly circuit

SS1

Selector switch (Main/sub)

R1T

Thermistor (Air)

SS

2

Selector switch (

W

ireless address set)

R

2

T

Thermistor (

C

oil)

Connector for optional parts

R

C

Signal recei

v

er circuit

X

2

4A

C

onnector (

W

ireless remote control)

S1L

Float switch

X33A

C

onnector (Ada

p

ter for wiring)

SS1

Selector switch (Emergency)

X35A

C

onnector (

G

rou

p

 control ada

p

ter)

T

C

Signal transmission circuit

X70A

C

onnector (Self cleaning 

p

anel)

X1M

Terminal stri

p

Wired remote control

X

2

M

Terminal stri

p

R1T

Thermistor (Air)

Z1

C

Ferrite core

SS1

Selector switch (Main/sub)   

: Terminal

C

olors:

RED

Red

YL

W

Yellow

BRN

Brown

C

onnector

BLK

Black

G

RN

G

reen

G

RY

G

rey

: Field wiring

W

HT

W

hite

OR

G

Orange

BLU

Blue

Indoor unit

(sla

v

e)

Indoor unit

(sla

v

e)

Remote control

To

 outdoor unit

C

ontrol box

To outdoor unit

Norm. emg.

Recei

v

er dis

p

lay unit

C

entral remote 

control (note1)

W

ired remote 

control

indoor

Exe

p

t for self 

cleaning 

p

anel 

(note 5)

In case of simultaneous operation system

35~140-Class

Summary of Contents for FCQH100D8VEB

Page 1: ...Cooling Only Heat Pump FCQH D8VEB air conditioning systems technical data...

Page 2: ...Cooling Only Heat Pump FCQH D8VEB air conditioning systems technical data...

Page 3: ...afety device settings 4 4 Options 5 5 Dimensional drawing centre of gravity 6 Dimensional drawing with standard panel 6 Dimensional drawing with auto cleaning panel 7 Dimensional drawing with accessoi...

Page 4: ...el in full white RAL9010 including white louvers auto cleaning panel 23 different air flow patterns possible Drain up pump with 850mm lift fitted as standard For auto cleaning panel Daikin introduces...

Page 5: ...21 9 34 2 34 2 34 2 Low m min 12 1 17 6 21 2 23 8 Heating High m min 21 9 34 2 34 2 34 2 Low m min 12 1 17 6 21 3 23 9 Fan Motor Model QTS48C15M Number of steps 3 Output high W 120 Cooling Sound Power...

Page 6: ...f dirt on white insulations is more visible and that it is consequently not advised to install the BYCQ140W1W decoration panel in environments exposed to concentrations of dirt 2 2 Electrical Specific...

Page 7: ...LU LQWDNH NLW IUHVK DLU KDPEHU W SH 4 6HDOLQJ PHPEHU RI DLU GLVFKDUJH RXWOHW 4 21752 6 67 0 WHP 0RGHO 4 4 4 4 4 4 4 4 4 4 4 5HPRWH FRQWURO LUHOHVV 3 5 2 5 LUHG 5 5 LULQJ DGDSWRU IRU HOHFWULFDO DSSHQGL...

Page 8: ...d polyethylene foam thickness 10 mm or more In case a discharge opening is closed with the sealing member option the distance of 1500 mm can be reduced to 500 mm on the closed side 300 or less 1500 mm...

Page 9: ...more 4 1500mm or more 4 1500mm or more 4 4 In case a discharge opening is closed with the sealing member option the distance of 1500mm can be reduced to 500 mm on the closed side FCQH100 140D8VEB 3TW...

Page 10: ...atic pressure of chamber Pa Inlet 306 In case a discharge opening is closed with the sealing member option the distance of 1500 mm can be reduced to 500 mm on the closed side FCQH100 125 140D8 3D05703...

Page 11: ...dimensions Pipe connection side Drain connection side Receiver installation procedure Receiver Decoration panel Remote controller holder installation procedure installation to wall surface Receiver de...

Page 12: ...Indoor Units 10 Indoor Units Cooling Only Heat Pump FCQH D8VEB 5 Dimensional drawing centre of gravity 5 5 Centre of gravity FCQH71 140D8 4TW28839 2 Models A B C D FCQH71 246 90 411 411 FCQH100 140 2...

Page 13: ...door Units Cooling Only Heat Pump FCQH D8VEB 6 Piping diagram FCQH71 140D8 3TW28925 1A Cooling Heating Liquid pipe connection port Gas pipe connection port Heat exchanger Fan Model Gas Liquid FCQH71 1...

Page 14: ...etic relay M1P H1P Light emitting diode On red M1F Motor Indoor fan H2P Light emitting diode Timer green M1P Motor Drain pump H3P Light emitting diode Filter sign red M1S Motor Swing ap H4P Light emit...

Page 15: ...weighted sound power level A scale according to IEC 5 Reference acoustic intensity 0dB 20 Pa Sound power level dB Octave band center frequency Hz Mic position FCQH125D8 3TW31777 3 NOTES 1 High tap Low...

Page 16: ...scale according to IEC 3 Reference acoustic intensity 0dB 10E 6 W m2 4 Measured according to ISO 3744 Sound power level dB Octave band center frequency Hz FCQH100 140D8 3TW31767 1 NOTES 1 High tap 2...

Page 17: ...13 Cooling air temperature distribution All round air discharge air flow direction horizontal Cooling air velocity distribution All round air discharge air flow direction horizontal 4m 3m 2m 1m 0m 1m...

Page 18: ...Cooling air temperature distribution All round air discharge air flow direction horizontal Cooling air velocity distribution All round air discharge air flow direction horizontal 4m 3m 2m 1m 0m 1m 2m...

Page 19: ...Cooling air temperature distribution All round air discharge air flow direction horizontal Cooling air velocity distribution All round air discharge air flow direction horizontal 4m 3m 2m 1m 0m 1m 2m...

Page 20: ...Cooling air temperature distribution All round air discharge air flow direction horizontal Cooling air velocity distribution All round air discharge air flow direction horizontal 4m 3m 2m 1m 0m 1m 2m...

Page 21: ...air temperature distribution All round air discharge air flow direction horizontal Heating air velocity distribution All round air discharge air flow direction horizontal 4m 3m 2m 1m 0m 1m 2m 3m 4m 4m...

Page 22: ...temperature distribution All round air discharge air flow direction horizontal Heating air velocity distribution All round air discharge air flow direction horizontal 4m 3m 2m 1m 0m 1m 2m 3m 4m 4m 3m...

Page 23: ...temperature distribution All round air discharge air flow direction horizontal Heating air velocity distribution All round air discharge air flow direction horizontal 4m 3m 2m 1m 0m 1m 2m 3m 4m 4m 3m...

Page 24: ...temperature distribution All round air discharge air flow direction horizontal Heating air velocity distribution All round air discharge air flow direction horizontal 4m 3m 2m 1m 0m 1m 2m 3m 4m 4m 3m...

Page 25: ...N V explicitly rejects any liability for any direct or indirect damage in the broadest sense arising from or related to the use and or interpretation of this publication All content is copyrighted by...

Reviews: