background image

5

English

Observe the following precautions to ensure the 
system operates.

Adjust the room temperature properly for a com-
fortable environment. Avoid excessive heating or 
cooling.

Prevent direct sunlight from entering a room dur-
ing cooling operation by using curtains or blinds.

Ventilate the room regularly.
Using the unit for long periods of time requires 
attentive ventilation of the room.

Keep doors and windows closed. If the doors and 
windows remain open, room air will flow out and 
cause to decrease the effect of cooling and heating.

Do not place other heaters directly below the 
indoor unit.
They may deform due to the heat.

Never place objects near the air inlet and the air 
outlet of the unit. It may cause deterioration in the 
effect or stop in the operation.

Turn off the main power supply switch when it is 
not used for long periods of time. When the main 
power switch is turned on, some watts of electricity 
is being used even if the system is not operating. 
Turn off the main power supply switch for saving 
energy. When reoperating, turn on the main power 
supply switch 6hours before operation for smooth 
running (Refer to MAINTENANCE).

When the display shows “

 

 (TIME TO CLEAN 

AIR FILTER), ask a qualified service person to 
clean the filter (Refer to MAINTENANCE).

Fully use the function of air flow direction adjust.
Cold air gathers on the floor, and warm air gathers 
in the ceiling.
Set the air flow direction parallel during cooling or 
dry operation, and set it downwards during heat-
ing operation.
Do not let the air blow directly to a person.

ONLY A QUALIFIED SERVICE PERSON IS 
ALLOWED TO PERFORM MAINTENANCE

IMPORTANT!

BEFORE OBTAINING ACCESS TO TERMINAL 
DEVICES, ALL POWER SUPPLY CIRCUITS 
MUST BE INTERRUPTED

To clean the air conditioner, be sure to stop oper-
ation, and turn the power switch off. Otherwise, an 
electric shock and injury may result.

Do not wash the air conditioner with water.
Doing so may result in an electric shock.

6. OPTIMUM OPERATION

7. MAINTENANCE

(FOR SERVICE PERSONNEL)

Be careful with a scaffold or staging.
Caution must be exercised because of work at a 
high place.

HOW TO CLEAN THE AIR FILTER

Clean the air filter when the display shows “

” 

(TIME TO CLEAN AIR FILTER). 

It will display that it will operate for a set amount of time.
Increase the frequency of cleaning if the unit is 
installed in a room where the air is extremely contami-
nated.
If the dirt becomes impossible to clean, change the air 
filter. (For changing air filter, please contact your 
dealer.)

1. Open the suction grille.

Pull it downward slowly while pressing the 
buttons provided on two spots.

(Do the same procedure for closing.)

2. Remove the air filters.

Pull the hook of the air filter out diagonally 
downward, and remove the filter.

3. Clean the air filter.

Use vacuum cleaner 

A)

 or wash the air filter with 

water

 B).

A)

Using a vacuum cleaner

B)

Washing with water
When the air filter is very 
dirty, use soft brush and 
neutral detergent.

Remove water and dry in the shade.

Fig. 1

Fig. 2

Summary of Contents for FCQ71DV3B

Page 1: ...s Espa ol Italiano Nederlands Portugues SPLIT SYSTEM Air Conditioner OPERATION MANUAL MODELS Ceiling mounted Multi flow Cassette type FCQ71DV3B FCQ71DAV3B FCQ100DV3B FCQ100DAV3B FCQ125DV3B FCQ125DAV3B...

Page 2: ...dicio nador de aire Daikin Lea cuidadosamente el manual de funcionamiento antes de utilizar el acondicionador de aire Dicho manual le indi car c mo utilizar adecuadamente la m quina y le ayudar en cas...

Page 3: ...gerante aceite y otros componentes debe ser efectuado por un instalador competente de acuerdo con las normas locales y nacionales aplicables Los acondicionadores de aire deben ser tratados en instalac...

Page 4: ...operation modes 1 WHAT TO DO BEFORE OPERATION Indoor unit Outdoor unit Unit with remote controller Unit without romote controller When used as simultaneous operation system PRECAUTIONS FOR GROUP CONTR...

Page 5: ...oxygen deficiency accident may happen 2 SAFETY CONSIDERATIONS For installation of separately sold compo nent parts ask a specialist Be sure to use the separately sold component parts designated by ou...

Page 6: ...ly if power failure compensation is enabled which may result in injury Do not place objects in direct proximity of the outdoor unit and do not let leaves and other debris accumulate around the unit Le...

Page 7: ...not carried out from the out door drain pipes during air conditioning operation chances are that dust and dirt are clogged in the pipe This may result in a water leakage from the indoor unit Under suc...

Page 8: ...iling Set the air flow direction parallel during cooling or dry operation and set it downwards during heat ing operation Do not let the air blow directly to a person ONLY A QUALIFIED SERVICE PERSON IS...

Page 9: ...off Do not use water or air of 50 C or higher for clean ing air filters and outside panels HOW TO CLEAN THE SUCTION GRILLE 1 Open the suction grille Push it downward slowly while pressing the but tons...

Page 10: ...lled by the remote con troller 8 NOT MALFUNCTION OF THE AIR CONDITIONER The system does not start immediately after the power supply is turned on Wait one minute until the micro computer is pre pared...

Page 11: ...does not operate at all Check if there is a power failure Wait until power is restored If power failure occurs during operation the system automati cally restarts immediately after the power sup ply...

Page 12: ...3P184442 8B EM04A036C 0704 HT FS...