To protect the unit, turn on the main power switch 
at least 6 hours before operation.

WHAT TO DO WHEN STOPPING THE SYS-
TEM FOR A LONG PERIOD

Turn on FAN OPERATION for a half day and dry 
the unit.

Read the operation manual attached to the 
remote controller.

Cut off the power supply.

When the main power switch is turned on, some 
watts of electricity is being used even if the sys-
tem is not operating.
Turn off the main power supply switch for saving 
energy.

The display on the remote controller will vanish 
when the main power switch is turned off. 

Clean the air filter and the exterior.

Be sure to replace the air filter to its original place 
after cleaning. Refer to “MAINTENANCE”.

The following symptoms do not indicate air condi-
tioner malfunction

I.

THE SYSTEM DOES NOT OPERATE

The system does not restart immediately 
after the ON/OFF button is pressed.

If the OPERATION lamp lights, the system is in 
normal condition.
It does not restart immediately because a safety 
device operates to prevent overload of the sys-
tem. After 3 minutes, the system will turn on 
again automatically.

The system does not restart immediately when 
TEMPERATURE SETTING button is returned to 
the former position after pushing the button.

If the OPERATION lamp lights, the system is in 
normal condition.
It does not restart immediately because a safety 
device operates to prevent overload of the sys-
tem. After 3 minutes, the system will turn on 
again automatically.

The system does not start when the display 
shows “

” (UNDER CENTRALIZED 

CONTROL) and it flashes for a few seconds 
after pressing an operation button.

This is because the system is under centralized 
control. Flashes on the display indicates that the 
system cannot be controlled by the remote con-
troller.

8. NOT MALFUNCTION OF THE AIR 

CONDITIONER

The system does not start immediately after 
the power supply is turned on.

Wait one minute until the micro computer is pre-
pared for operation.

II. WHITE MIST COMES OUT OF A UNIT

When humidity is high during cooling opera-
tion. (In oily or dusty places)

If the inside of an indoor unit is extremely con-
taminated, the temperature distribution inside a 
room becomes uneven. It is necessary to clean 
the inside of the indoor unit. Ask your Daikin 
dealer for details on cleaning the unit. This oper-
ation requires a qualified service person.

When the system is changed over to HEATING 
OPERATION after DEFROST OPERATION.

Moisture generated by DEFROST becomes 
steam and exists.

III. NOISE OF AIR CONDITIONERS

A ringing sound after the unit is started.

This sound is generated by the temperature reg-
ulator working. 
It will quiet down after about a minute.

A continuous flow “Shuh” sound is heard 
when the systems is in COOLING or 
DEFROST OPERATION.

This is the sound of refrigerant gas flowing 
through both indoor and outdoor units.

A “Shuh” sound which is heard at the start or 
immediately after the stop of operation or 
which is heard at the start or immediately 
after the stop of DEFROST OPERATION. 

This is the noise of refrigerant caused by flow 
stop and flow change.

A continuous low “Shah” sound is heard 
when the system is in COOLING OPERATION 
or at a stop.

The noise is heard when the drain pump is in 
operation.

A “Pishi-pishi” squeaking sound is heard 
when the system is in operation or after the 
stop of operation.

Expansion and contraction of plastic parts 
caused by temperature change makes this noise.

IV. DUST FROM THE UNITS

Dust may blow out from the unit after starting 
operation from long resting time.

Dust absorbed by the unit blows out.

V. THE UNITS GIVE OFF ODORS

The unit absorbs the smell of rooms, furniture, 
cigarettes, etc., and then emits them.

Summary of Contents for FCQ71DV3B

Page 1: ...s Espa ol Italiano Nederlands Portugues SPLIT SYSTEM Air Conditioner OPERATION MANUAL MODELS Ceiling mounted Multi flow Cassette type FCQ71DV3B FCQ71DAV3B FCQ100DV3B FCQ100DAV3B FCQ125DV3B FCQ125DAV3B...

Page 2: ...dicio nador de aire Daikin Lea cuidadosamente el manual de funcionamiento antes de utilizar el acondicionador de aire Dicho manual le indi car c mo utilizar adecuadamente la m quina y le ayudar en cas...

Page 3: ...gerante aceite y otros componentes debe ser efectuado por un instalador competente de acuerdo con las normas locales y nacionales aplicables Los acondicionadores de aire deben ser tratados en instalac...

Page 4: ...operation modes 1 WHAT TO DO BEFORE OPERATION Indoor unit Outdoor unit Unit with remote controller Unit without romote controller When used as simultaneous operation system PRECAUTIONS FOR GROUP CONTR...

Page 5: ...oxygen deficiency accident may happen 2 SAFETY CONSIDERATIONS For installation of separately sold compo nent parts ask a specialist Be sure to use the separately sold component parts designated by ou...

Page 6: ...ly if power failure compensation is enabled which may result in injury Do not place objects in direct proximity of the outdoor unit and do not let leaves and other debris accumulate around the unit Le...

Page 7: ...not carried out from the out door drain pipes during air conditioning operation chances are that dust and dirt are clogged in the pipe This may result in a water leakage from the indoor unit Under suc...

Page 8: ...iling Set the air flow direction parallel during cooling or dry operation and set it downwards during heat ing operation Do not let the air blow directly to a person ONLY A QUALIFIED SERVICE PERSON IS...

Page 9: ...off Do not use water or air of 50 C or higher for clean ing air filters and outside panels HOW TO CLEAN THE SUCTION GRILLE 1 Open the suction grille Push it downward slowly while pressing the but tons...

Page 10: ...lled by the remote con troller 8 NOT MALFUNCTION OF THE AIR CONDITIONER The system does not start immediately after the power supply is turned on Wait one minute until the micro computer is pre pared...

Page 11: ...does not operate at all Check if there is a power failure Wait until power is restored If power failure occurs during operation the system automati cally restarts immediately after the power sup ply...

Page 12: ...3P184442 8B EM04A036C 0704 HT FS...

Reviews: