8

STOPPING THE SYSTEM

6. Press ON/OFF button once again.

• OPERATION lamp goes off, and the system stops 

OPERATION.

• The fan may keep on running for about 1 minute after 

the heating operation stops.
(To start the next operation smoothly.)

ATTENTION:

• Do not turn OFF power immediately after the unit stops.

Then, wait no less than 5 minutes. Water is leaking or 
there is something else wrong with the unit.

• When the operation is started again immediately after being 

stopped, when the operation mode is changed over, or when 
the TEMPERATURE SETTING button is pressed then 
returned soon, the air conditioner will start the operation 
automatically about 5 minutes later (because the air condi-
tioner is controlled so that excessive load is not applied).

Characteristics of the heating operation

(1) DEFROST OPERATION

• As the frost on the coil of an outdoor unit increase, 

heating effect decreases and the system goes into 
DEFROST OPERATION.

• The indoor unit fan stops and the remote controller dis-

plays shows “

” (DEFROST/HOT START).

• After 6 to 8 minutes (maximum 10 minutes) of 

DEFROST OPERATION, the system returns to HEAT-
ING OPERATION.

(2) HOT START

• In order to prevent cold air from blowing out of an 

indoor unit at the start of heating operation, the indoor 
fan is automatically stopped. The display of the remote 
controller shows “

” (DEFROST/HOT START).

(3) OPERATION START

• For ordinary heating, it will take longer for the room 

temperature to reach the set temperature than with 
cooling. We therefore recommend starting the unit 
ahead of time using the timer operation.

ADJUSTING THE AIR FLOW DIRECTION

• Press the AIR FLOW DIRECTION button to adjust the air 

flow angle.

1. Press the AIR FLOW DIRECTION ADJUST button to 

select the air direction as shown below.

The AIR FLOW FLAP display swings 
as shown left and the air flow direction 
continuously varies. 
(Automatic swing setting)

Press AIR FLOW DIRECTION 
ADJUST button to select the air 
direction of your choice.

The AIR FLOW FLAP display stops 
swinging and the air flow direction is 
fixed. 
(Fixed air flow direction setting)

MOVEMENT OF THE AIR FLOW FLAP

For the following conditions, micro computer controls the air 
flow direction so it may be different from the display.

Operation mode include automatic operation.
The air flow direction can be adjusted in either of the following 
ways.

• Automatic

The air flow flap adjusts its position itself.

• Fixed air flow direction

The air flow direction can be fixed by the user.

<Automatic>

<Fixed air flow direction>

ATTENTION:

• The movable limit of the flap is changeable. Contact your 

Daikin dealer for details.

• Avoid operating in the horizontal direction “

” which 

may cause dew or dust to settle on ceiling.

PROGRAM TIMER Operation
Operate in the following order.

• The timer is operated by the following two ways.

Programming the stop time (

)..............................

The system stops operating after the time setting has 
elapsed.
Programming the start time (

)...............................

The system starts operating after the time setting has 
elapsed.

• The timer can be programmed for a maximum of 72 hours.
• The start and the stop time can simultaneously be 

programmed.

 Refer to figure 4 on page 3 

1. Press the TIMER MODE START/STOP button several 

times and select the mode on the display.

The display flashes.

For setting the timer stop ......... “

For setting the timer start ......... “

2. Press the PROGRAMMING TIME button and set the 

time for stopping or starting the system.

When this button is pressed, the time advances 
by 1 hour.
When this button is pressed, the time goes 
backward by 1 hour.

3. Press the TIMER ON/OFF button.

The timer setting procedure ends.

The display “

or

” changes from flashing 

light to a constant light.

NOTE

• When setting the timer Off and On at the same time, 

repeat the above procedure (from 

1

 to 

3

) once again.

• After the timer is programmed, the display shows the 

remaining time.

Up and down adjustment

swing

Operation 

mode

Cooling

Heating

Operation 

conditions

• When room tem-

perature is lower 
than the set tem-
perature

• When room tempera-

ture is higher than the 
set temperature

• At defrost operation

• When operating 

continuously at 
horizontal air 
flow direction

01_EN_3P177429-3F.fm  Page 8  Wednesday, July 4, 2007  10:03 AM

Summary of Contents for FCQ100KVEA

Page 1: ...ditioners Thank you for purchasing this Daikin air conditioner Carefully read this operation manual before using the air conditioner It will tell you how to use the unit properly and help you if any t...

Page 2: ...3 4 2 TEST C hr hr TEST NOT AVAILABLE L H 2 9 10 3 1 4 5 6 7 13 14 15 16 17 18 19 20 21 11 8 12 a b c d e l m g f h n i k j C hr H 3 1...

Page 3: ...t prolonged direct exposure to cool or warm air from the air conditioner or to air that is too cool or too warm can be harmful to your physical condition and health When the air conditioner is malfunc...

Page 4: ...hat the room is adequately ventilated if equipment such as a burner is used together with the air conditioner After prolonged use check the unit stand and its mounts for damage If left in a damaged co...

Page 5: ...ler Regarding wiring All wiring must be performed by an authorized electri cian To do wiring ask your dealer Never do it by yourself Make sure that a separate power supply circuit is pro vided for thi...

Page 6: ...3 DISPLAY UNDER CENTRALIZED CONTROL When this display shows the system in UNDER CENTRALIZED CONTROL This is not a standard specification 4 DISPLAY OPERA TION MODE This display shows the current OPERAT...

Page 7: ...choice The AIR FLOW FLAP display stops swinging and the air flow direction is fixed Fixed air flow direction setting MOVEMENT OF THE AIR FLOW FLAP For the following conditions micro computer controls...

Page 8: ...ring cooling or dry operation and set it downwards during heating operation Do not let the air blow directly to a person It takes time for the room temperature to reach the set tem perature We recomme...

Page 9: ...e it as below and clean or exchange it For changing the flap please contact your dealer NOTE Do not use gasoline benzene thinner polishing powder liquid insecticide It may cause discoloring or warping...

Page 10: ...in normal condition It does not restart immediately because a safety device operates to prevent overload of the system After 3 min utes the system will turn on again automatically The system does not...

Page 11: ...pply Is the breaker blown Turn the power on with the breaker switch in the off position Do not turn the power on with the breaker switch in the trip position Contact your dealer 2 If the system stops...