background image

Installer and user reference guide

Split system air conditioners

English

Installer and user

reference guide

Split system air conditioners

FCAHG71FVEB    
FCAHG100FVEB    
FCAHG125FVEB    
FCAHG140FVEB

Summary of Contents for FCAHG100FVEB

Page 1: ...Installer and user reference guide Split system air conditioners English Installer and user reference guide Split system air conditioners FCAHG71FVEB FCAHG100FVEB FCAHG125FVEB FCAHG140FVEB...

Page 2: ...lectrical wiring 15 6 4 3 Guidelines when connecting the electrical wiring 15 6 4 4 Specifications of standard wiring components 15 6 4 5 To connect the electrical wiring on the indoor unit 15 7 Confi...

Page 3: ...ilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play...

Page 4: ...here there is machinery that emits electromagnetic waves Electromagnetic waves may disturb the control system and cause malfunction of the equipment In places where there is a risk of fire due to the...

Page 5: ...3 EC 1 3 6 Electrical DANGER RISK OF ELECTROCUTION Turn OFF all power supply before removing the switch box cover connecting electrical wiring or touching electrical parts Disconnect the power supply...

Page 6: ...s or for commercial use by lay persons Documentation set This document is part of a documentation set The complete set consists of General safety precautions Safety instructions that you must read bef...

Page 7: ...or and indoor units Combining the indoor unit with options INFORMATION For year round cooling applications with low indoor humidity conditions such as Electronic Data Processing rooms contact your dea...

Page 8: ...g the unit in and out of the site 5 2 1 Installation site requirements of the indoor unit INFORMATION Also read the following requirements General installation site requirements See the General safety...

Page 9: ...epends on the air flow directions towards the wall 1500 500 200 a A A A b c a Air outlet and corners open b Air outlet closed corners open optional blocking pad kit required c Air outlet and corners c...

Page 10: ...ng Checking the refrigerant piping Charging refrigerant Connecting the electrical wiring Finishing the outdoor installation Finishing the indoor installation INFORMATION This chapter only describes in...

Page 11: ...d e f a b a Drain piping b Refrigerant piping c Hanger bracket pitch suspension d Unit e Ceiling opening f Decoration panel If A Then B C A C B 860 mm min 20 mm 35 mm 910 mm max 35 mm 20 mm A Ceiling...

Page 12: ...installation space and surroundings 1 Push the drain hose as far as possible over the drain pipe connection 2 Tighten the metal clamp until the screw head is less than 4 mm from the metal clamp part...

Page 13: ...Do NOT use mineral oil on flared part NEVER install a drier to this R32 unit to guarantee its lifetime The drying material may dissolve and damage the system NOTICE Take the following precautions on...

Page 14: ...prevent creation of large quantities of oxidised film on the inside of the piping This film adversely affects valves and compressors in the refrigerating system and prevents proper operation Set the n...

Page 15: ...c Flat washer Tightening torques Wiring Screw size Tightening torque N m Interconnection cable indoor outdoor M4 1 18 1 44 User interface cable M3 5 0 79 0 97 6 4 4 Specifications of standard wiring c...

Page 16: ...round air flow use the table below If the distance to the floor is m Then1 FCAHG71 FCAHG100 140 M C1 C2 2 7 3 2 13 23 0 01 2 7 x 3 0 3 2 x 3 6 02 3 0 x 3 5 3 6 x 4 2 03 Setting Air flow direction This...

Page 17: ...valves failing to open can be detected Even if the user interface was set to heating operation mode the unit will run in cooling operation mode during 2 3 minutes although the user interface will disp...

Page 18: ...within 10 seconds Test run starts 3 Check operation for 3 minutes 4 Check operation of the airflow direction Action Result 1 Press Return Setting Return Setting Air Volume direction Air Volume Directi...

Page 19: ...nit are incompatible 9 Hand over to the user Once the test run is finished and the unit operates properly please make sure the following is clear for the user Make sure that the user has the printed d...

Page 20: ...0 55 55 35 35 125 130 112 153 298 840 55 55 10 40 175 340 0 675 280 330 75 180 213 A c b i g a j d h a e f b c d j e f In case of installation with self cleaning decoration panel 75 210 420 420 710 86...

Page 21: ...wall 1500 500 200 a A A A b c a Air outlet and corners open b Air outlet closed corners open optional blocking pad kit required c Air outlet and corners closed optional blocking pad kit required B Mi...

Page 22: ...side forced off or on off control operation can be selected by the remote controller See installation manual for more details 5 Connect power of adapter for wiring to terminal block X2M of indoor unit...

Page 23: ...staller and user reference guide 23 FCAHG71 140FVEB Split system air conditioners 4P429475 1 2015 12 X A PCB connector X M Terminal strip X Y Connector Z C Noise filter ferrit core Z F Noise filter Op...

Page 24: ...o fan Number of fans 1 Number of motors output 48 W 106 W Fan speed 5 steps Piping connections Liquid outer diameter 9 52 mm flare Gas outer diameter 15 9 mm flare Drain outer diameter Vinyl pipe 25 m...

Page 25: ...ARNING This unit contains electrical and hot parts WARNING Before operating the unit be sure the installation has been carried out correctly by an installer CAUTION It is not good for your health to e...

Page 26: ...r Contact your dealer for details 15 2 4 To operate the system 1 Press the operation mode selector button on the user interface several times and select the operation mode of your choice Cooling opera...

Page 27: ...s blocked 17 Maintenance and service NOTICE Never inspect or service the unit by yourself Ask a qualified service person to perform this work However as end user you may clean the air filter suction g...

Page 28: ...move stains use water or neutral detergent 17 2 Maintenance after a long stop period E g at the beginning of the season Check and remove everything that might be blocking inlet and outlet vents of ind...

Page 29: ...leaks into a room where combustible air from fan heaters gas cookers etc is present Always have qualified service personnel confirm that the point of leakage has been repaired or corrected before res...

Page 30: ...or indoor unit is not blocked by obstacles Remove any obstacle and make it well ventilated Check if the air filter is not clogged see 17 1 1 To clean the air filter on page 27 Check the temperature s...

Page 31: ...frost operation This is the noise of refrigerant caused by flow stop or flow change 18 1 9 Symptom Noise of air conditioners Outdoor unit When the tone of operating noise changes This noise is caused...

Page 32: ...015 12 Optional equipment Equipment made or approved by Daikin that can be combined with the product according to the instructions in the accompanying documentation Field supply Equipment not made by...

Page 33: ......

Page 34: ......

Page 35: ......

Page 36: ...4P429475 1 2015 12 Copyright 2015 Daikin...

Reviews: