If the temperature or the humidity is beyond the fol-
lowing conditions, safety devices may work and the 
air conditioner may not operate, or sometimes, 
water may drop from the indoor unit.
COOLING ONLY TYPE

HEAT PUMP TYPE

D B: Dry bulb temperature
WB: Wet bulb temperature

The setting temperature range of the remote con-
troller is 16°C to 32°C.

Regarding places for installation

• Is the air conditioner installed at a well-ventilated 

place where there are no obstacles around?

• Do not use the air conditioner in the following 

places.

a. Filled with much mineral oil such as cutting oil
b. Where there is much salt such as a beach area
c. Where sulfured gas exists such as a hot-spring 

resort

d. Where there are considerable voltage fluctua-

tions such as a factory or plant

e. Vehicles and vessels

 

f

 

. Where there is much spray of oil and vapor 

such as a cookery, etc.

g. Where there are machines generating electro-

magnetic waves

h. Filled with acid and/or alkaline steam or vapor

• Is a snow protection measure taken?

For details, consult your dealer.

3. OPERATION RANGE

TEMPERATURE[°C]

OUTDOOR

INDOOR

–5 to 46(DB)

21 to 32(DB)/

14 to 23(WB)

OPERATION

TEMPERATURE[°C]

OUTDOOR

INDOOR

COOLING

–5 to 46(DB)

21 to 32(DB)/

14 to 23(WB)

HEATING

–14 to 21(DB)/

–15 to 15.5(WB)

14 to 28(DB)

4. INSTALLATION SITE

Regarding wiring

• All wiring must be performed by an authorized 

electrician.

To do wiring, ask your dealer. Never do it by yourself.

• Make sure that a separate power supply cir-

cuit is provided for this air conditioner and 
that all electrical work is carried out by quali-
fied personnel according to local laws and 
regulations.

Pay attention to running noises, too

• Are the following places selected?

a. A place that can sufficiently withstand the 

weight of the air conditioner with less running 
noises and vibrations.

b. A place where the hot wind discharged from the 

air outlet of the outdoor unit and the running 
noises.

• Are you sure that there are no obstacles near 

the air outlet of the outdoor unit?

Such obstacles may result in declined perfor-
mance and increased running noises.

• If abnormal noises occur in use, consult your 

dealer.

Regarding drainage of drain piping

• Is the drain piping executed to perform com-

plete drainage?

If proper drainage is not carried out from the out-
door drain pipes during air-conditioning operation, 
chances are that dust and dirt are clogged in the 
pipe. This may result in a water leakage from the 
indoor unit. Under such circumstances, stop the 
operation of the air conditioner, and then consult 
your dealer or our service station.

01_EN_3P156215-3.fm  Page 3  Monday, February 7, 2005  12:18 PM

Summary of Contents for FBQ60BV1

Page 1: ...English SPLIT SYSTEM Air Conditioner OPERATION MANUAL MODELS Ceiling mounted cassette built in type FBQ60BV1 FBQ60BVL FBQ71BV1 FBQ71BVL OO_3P156215 3_CV 1 fm Page 1 Friday January 21 2005 5 24 PM...

Page 2: ...ly read this operation manual before using the air conditioner It will tell you how to use the unit properly and help you if any trouble occurs After reading the manual file it away for future referen...

Page 3: ...1 1 3 4 2 2 9 3 1 4 5 6 7 12 13 14 15 16 17 18 19 10 8 11 TEST C hr hr TEST NOT AVAILABLE L H a h c g b f e d C hr H OO_3P156215 3_CV2 fm Page 1 Monday January 24 2005 2 11 PM...

Page 4: ...e unit is individually operated 1 WHAT TO DO BEFORE OPERA TION NOTE Contact your Daikin dealer in case of changing the combination or setting of group control and two remote controllers control system...

Page 5: ...for a special appli cation such as the storage of foods animals and plants precision machines and art objects as otherwise the deterioration of quality may result Donotremovetheairoutletoftheoutdoorun...

Page 6: ...14 to 23 WB HEATING 14 to 21 DB 15 to 15 5 WB 14 to 28 DB 4 INSTALLATION SITE Regarding wiring All wiring must be performed by an authorized electrician To do wiring ask your dealer Never do it by yo...

Page 7: ...cooling only type Contact your Daikin dealer to confirm your system type To protect the unit turn on the main power switch 6 hours before operation If the main power supply is turned off during oper...

Page 8: ...herefore it takes some time until the entire room is warmed up after the start of operation COOLING HEATING AUTOMATIC FAN AND PROGRAM DRY OPERATION 1 2 An indoor fan runs to discharge a gentle wind au...

Page 9: ...decrease the effect of cooling and heating Do not place other heaters directly below the indoor unit They may deform due to the heat Never place objects near the air inlet and the air outlet of the un...

Page 10: ...the air filter up Confirm that four hangers are fixed Refer to Fig 4 5 Close the suction grille Refer to item No 1 6 After turning on the power press FILTER SIGN RESET button The display TIME TO CLEAN...

Page 11: ...pressing an operation button This is because the system is under centralized con trol Flashes on the display indicates that the system cannot be controlled by the remote controller The system does no...

Page 12: ...investigate the system according to the following procedures 1 If the system does not operate at all Check if there is a power failure Wait until power is restored If power failure occurs during oper...

Page 13: ...3P156215 3 EM04A075 0502 HT OO_3P156215 3_CV 1 fm Page 2 Friday January 21 2005 5 24 PM...

Reviews: