V. THE UNITS GIVE OFF ODORS

The unit absorbs the smell of rooms, furniture, 
cigarettes, etc., and then emits them.

VI.THE LIQUID CRYSTAL OF THE REMOTE CON-

TROLLER SHOW “

• It happens immediately after the main power 

supply switch is turned on.

This shows that the remote controller is in normal 
condition. 
This continues temporary.

I. If one of the following malfunctions occurs, 

take the measures shown below and contact 

your Daikin dealer.

The system must be repaired by a qualified service 
person. 

WARNING

When the air conditioner is in abnormal con-

ditions (smell of something burning, etc), 

turn off power, and contact your dealer

Continued operation under such circumstances 

may result in a failure, electric shock, and fire.

If a safety device such as a fuse, a breaker, or an 
earth leakage breaker frequently actuates, or ON/
OFF switch does not properly work.

Measure: 

 Turn off the main power switch

If water leaks from unit.

Measure:

  Stop the operation.

If the display “ 

 ” (INSPECTION), “UNIT No.”, 

and the OPERATION lamp flash and the “MAL-
FUNCTION CODE” appears.

Measure:

 Notify your Daikin dealer and inform 

him/her of the display.

10. TROUBLE SHOOTING

OPERATION lamp

INSPECTION 
display

MALFUNCTION CODE

INDOOR UNIT No. in 
which a malfunction occurs

UNIT   No.

C

L

  H     

II. If the system does not properly operate 

except for the above mentioned case, and 

none of the above mentioned malfunctions is 

evident, investigate the system according to 

the following procedures.

1. If the system does not operate at all.

Check if there is a power failure.
Wait until power is restored. If power failure 
occurs during operation, the system automati-
cally restarts immediately after the power sup-
ply recovers.

Check if the fuse has blown or breaker has 
worked. 
Change the fuse or set the breaker.

2. If the system stops operating after operating 

the system.

Check if the air inlet or outlet of outdoor or 
indoor unit is blocked by obstacles.
Remove the obstacle and make it well-venti-
lated.

Check if the air filter is clogged.
Ask a qualified service person to clean the air 
filters (Refer to MAINTENANCE).

3. The system operates but it does not suffi-

ciently cool or heat.

If the air inlet or outlet of the indoor or the out-
door unit is blocked with obstacles.
Remove the obstacle and make it well-venti-
lated. 

If the air filter is clogged.
Ask a qualified service person to clean the air 
filters (Refer to MAINTENANCE).

If the set temperature is not proper (Refer to 
ADJUSTMENT).

If the FAN SPEED button is set to LOW 
SPEED (Refer to ADJUSTMENT).

If the doors or the windows are open. Shut 
doors or windows to prevent wind from coming 
in.

If direct sunlight enters the room (when cool-
ing).
Use curtains or blinds.

When there are too many inhabitants in the 
room (when cooling).
Cooling effect decreases if heat gain of the 
room is too large.

If the heat source of the room is excessive 
(when cooling).
Cooling effect decreases if heat gain of the 
room is too large.

01_EN_3P156215-3.fm  Page 9  Monday, February 7, 2005  12:18 PM

Summary of Contents for FBQ60BV1

Page 1: ...English SPLIT SYSTEM Air Conditioner OPERATION MANUAL MODELS Ceiling mounted cassette built in type FBQ60BV1 FBQ60BVL FBQ71BV1 FBQ71BVL OO_3P156215 3_CV 1 fm Page 1 Friday January 21 2005 5 24 PM...

Page 2: ...ly read this operation manual before using the air conditioner It will tell you how to use the unit properly and help you if any trouble occurs After reading the manual file it away for future referen...

Page 3: ...1 1 3 4 2 2 9 3 1 4 5 6 7 12 13 14 15 16 17 18 19 10 8 11 TEST C hr hr TEST NOT AVAILABLE L H a h c g b f e d C hr H OO_3P156215 3_CV2 fm Page 1 Monday January 24 2005 2 11 PM...

Page 4: ...e unit is individually operated 1 WHAT TO DO BEFORE OPERA TION NOTE Contact your Daikin dealer in case of changing the combination or setting of group control and two remote controllers control system...

Page 5: ...for a special appli cation such as the storage of foods animals and plants precision machines and art objects as otherwise the deterioration of quality may result Donotremovetheairoutletoftheoutdoorun...

Page 6: ...14 to 23 WB HEATING 14 to 21 DB 15 to 15 5 WB 14 to 28 DB 4 INSTALLATION SITE Regarding wiring All wiring must be performed by an authorized electrician To do wiring ask your dealer Never do it by yo...

Page 7: ...cooling only type Contact your Daikin dealer to confirm your system type To protect the unit turn on the main power switch 6 hours before operation If the main power supply is turned off during oper...

Page 8: ...herefore it takes some time until the entire room is warmed up after the start of operation COOLING HEATING AUTOMATIC FAN AND PROGRAM DRY OPERATION 1 2 An indoor fan runs to discharge a gentle wind au...

Page 9: ...decrease the effect of cooling and heating Do not place other heaters directly below the indoor unit They may deform due to the heat Never place objects near the air inlet and the air outlet of the un...

Page 10: ...the air filter up Confirm that four hangers are fixed Refer to Fig 4 5 Close the suction grille Refer to item No 1 6 After turning on the power press FILTER SIGN RESET button The display TIME TO CLEAN...

Page 11: ...pressing an operation button This is because the system is under centralized con trol Flashes on the display indicates that the system cannot be controlled by the remote controller The system does no...

Page 12: ...investigate the system according to the following procedures 1 If the system does not operate at all Check if there is a power failure Wait until power is restored If power failure occurs during oper...

Page 13: ...3P156215 3 EM04A075 0502 HT OO_3P156215 3_CV 1 fm Page 2 Friday January 21 2005 5 24 PM...

Reviews: