6 Troubleshooting

Operation manual

7

FBA35~1FBA35~71A2VEB9
Split system air conditioners
4P456964-1C – 2018.08

Malfunction

Measure

The system operates
but cooling or heating
is insufficient.

▪ Check  if  air  inlet  or  outlet  of  outdoor  or

indoor  unit  is  not  blocked  by  obstacles.
Remove  any  obstacles  and  make  sure
the air can flow freely.

▪ Check  if  the  air  filter  is  clogged.  Contact

your dealer to clean the air filter (refer to
"Maintenance" in the indoor unit manual).

▪ Check  the  temperature  setting.  Refer  to

the manual of the user interface.

▪ Check  if  the  fan  speed  setting  is  set  to

low  speed.  Refer  to  the  manual  of  the
user interface.

▪ Check  if  the  air  flow  angle  is  proper.

Refer to the manual of the user interface.

▪ Check for open doors or windows. Close

doors and windows to prevent wind from
coming in.

▪ Check  if  direct  sunlight  enters  the  room.

Use curtains or blinds.

▪ Check if there are too many occupants in

the room during cooling operation. Check
if  the  heat  source  of  the  room  is
excessive.

▪ If  the  heat  source  of  the  room  is

excessive  (when  cooling).  Cooling  effect
decreases if heat gain of the room is too
large.

Operation stops
suddenly. (Operation
lamp blinks.)

▪ Check  if  the  air  filter  is  clogged.  Contact

your dealer to clean the air filter (refer to
"Maintenance" in the indoor unit manual).

▪ Check  if  air  inlet  or  outlet  of  outdoor  or

indoor  unit  is  not  blocked  by  obstacles.
Remove  any  obstacles,  turn  the  breaker
OFF and back ON. If the lamp still blinks,
contact your dealer.

▪ Check  if  all  indoor  units  connected  to

outdoor  unit  in  the  multi-system  are
operating in the same mode.

An abnormal function
happens during
operation.

▪ The  air  conditioner  may  malfunction

because of lightning or radio waves. Turn
the breaker OFF and back ON.

If  after  checking  all  above  items,  it  is  impossible  to  fix  the  problem
yourself, contact your installer and state the symptoms, the complete
model name of the unit (with manufacturing number if possible) and
the installation date (possibly listed on the warranty card).

6.1

Symptoms that are NOT system
malfunctions

The following symptoms are NOT system malfunctions:

6.1.1

Symptom: The system does not operate

▪ The  air  conditioner  does  not  start  immediately  after  the  ON/OFF

button  on  the  user  interface  is  pressed.  If  the  operation  lamp
lights, the air conditioner is in normal condition. It does not restart
immediately because one of its safety devices actuates to prevent
the air conditioner from being overloaded. The air conditioner will
turn on again automatically after 3 minutes.

▪ The  air  conditioner  does  not  start  immediately  after  the  power

supply  is  turned  on.  Wait  1  minute  until  the  microcomputer  is
prepared for operation.

▪ The  air  conditioner  does  not  restart  immediately  when  the

temperature  setting  button  is  returned  to  its  former  position  after
pushing. It does not restart immediately because one of its safety

devices  actuates  to  prevent  the  air  conditioner  from  being
overloaded.  The  air  conditioner  will  turn  on  again  automatically
after 3 minutes.

▪ The  outdoor  unit  has  stopped.  This  is  because  the  room

temperature  has  reached  the  set  temperature.  The  unit  switches

to fan operation. "

" (external control icon) is displayed on

the  user  interface  and  the  actual  operation  is  different  from  the
user  interface  setting.  For  multi-split  models,  the  microcomputer
executes  the  following  control  depending  on  the  operation  mode
of other indoor units.

▪ The fan speed is different from the setting. Pressing the fan speed

control  button  does  not  change  the  fan  speed.  When  the  room
temperature  reaches  the  set  temperature  in  heating  mode  or  the
unit’s  maximum  capacity  is  reached,  the  outdoor  unit  will  stop
operation  and  the  indoor  unit  will  operate  in  fan  only  mode  (low
fan  speed).  In  case  of  multi-split,  the  indoor  unit  alternately
operates  in  fan  stop  mode  and  fan  only  mode  (LL=  low  fan
speed).  This  is  to  prevent  the  cool  air  from  being  blown  directly
onto anyone present in the room.

6.1.2

Symptom: White mist comes out of a unit
(Indoor unit)

▪ When humidity is high during cooling operation (in oily and dusty

places). If the interior of an indoor unit is extremely contaminated,
the  temperature  distribution  inside  a  room  becomes  uneven.  It  is
necessary to clean the interior of the indoor unit. Ask your dealer
for details on cleaning the unit. This operation requires a qualified
service person.

▪ When  the  air  conditioner  is  changed  over  to  heating  operation

after  defrost  operation.  Moisture  generated  by  defrost  becomes
steam and exits.

6.1.3

Symptom: Dust comes out of the unit

When  the  unit  is  used  for  the  first  time  in  a  long  time.  This  is
because dust has gotten into the unit.

6.1.4

Symptom: The units can give off odours

The  unit  can  absorb  the  smell  of  rooms,  furniture,  cigarettes,  etc.,
and then emit it again.

6.1.5

Symptom: The operation stopped
suddenly (Operation lamp is on)

The  air  conditioner  may  stop  for  system  protection  due  to  large
voltage fluctuation. It automatically resumes operation after about 3
minutes.

6.1.6

Symptom: The outdoor fan rotates while
the air conditioner is not in operation

After  operation  has  stopped.

  The  outdoor  fan  continues  to

rotate for another 30 seconds for system protection.

While the air conditioner is not in operation.

 When the outdoor

temperature  is  very  high,  the  outdoor  fan  starts  to  rotate  for
system protection.

6.1.7

Symptom: The heating operation stops
suddenly and a flowing sound is heard

The system is removing frost on the outdoor unit. You should wait for
about 3 to 8 minutes.

Summary of Contents for FBA100A2VEB

Page 1: ...al Split system air conditioners English Operation manual Split system air conditioners FBA35A2VEB FBA50A2VEB FBA60A2VEB FBA71A2VEB FBA100A2VEB FBA125A2VEB FBA140A2VEB FBA35A2VEB9 FBA50A2VEB9 FBA60A2VEB9 FBA71A2VEB9 ...

Page 2: ...y precautions Safety instructions that you must read before operating your system Format Paper in the box of the indoor unit Operation manual Quick guide for basic usage Format Paper in the box of the indoor unit User reference guide Detailed step by step instructions and background information for basic and advanced usage Format Digital files on http www daikineurope com support and manuals produ...

Page 3: ...on with R410A outdoor unit refer to the following table Outdoor units Cooling Heating RR71 125 15 46 C DB 18 37 C DB 12 28 C WB RQ71 125 5 46 C DB 9 21 C DB 10 15 C WB 18 37 C DB 12 28 C WB 10 27 C DB RXS35 60 10 46 C DB 15 24 C DB 16 18 C WB 18 32 C DB 10 30 C DB 3MXS40 68 4MXS68 80 5MXS90 10 46 C DB 15 24 C DB 16 18 C WB 18 32 C DB 10 30 C DB Outdoor units Cooling Heating RZQG71 140 15 50 C DB 1...

Page 4: ... may cause a reduced heating cooling effect or stop operation Turn off the main power supply switch to the unit when the unit is NOT used for longer periods of time If the main power supply switch is on the unit consumes electricity Before restarting the unit turn on the main power supply switch 6 hours before operation to ensure smooth running When the display shows time to clean the air filter c...

Page 5: ...ter if the drain pump is not used or before maintenance Insert and remove the drain plug gently Excessive force may deform the drain socket of the drain pan 1 Pull out the plug Do NOT wiggle the plug up and down a 2 Push in the plug Set the plug and push it in using a Phillips screwdriver a b a Drain plug b Phillips screwdriver 5 4 Cleaning the air filter suction grille air outlet and outside pane...

Page 6: ... operation manuals of dedicated indoor units Make sure to install cleaned air filters back in the same position Turn on the power at least 6 hours before operating the unit in order to ensure smoother operation As soon as the power is turned on the user interface display appears 6 Troubleshooting If one of the following malfunctions occur take the measures shown below and contact your dealer WARNI...

Page 7: ...uter is prepared for operation The air conditioner does not restart immediately when the temperature setting button is returned to its former position after pushing It does not restart immediately because one of its safety devices actuates to prevent the air conditioner from being overloaded The air conditioner will turn on again automatically after 3 minutes The outdoor unit has stopped This is b...

Page 8: ...s 4P456964 1C 2018 08 7 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Units MUST be treated at a specialised treatment facility for reuse recycling and recovery ...

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ...4P456964 1C 2018 08 Copyright 2017 Daikin ...

Reviews: