6 Troubleshooting

Operation manual

6

FBA35~1FBA35~71A2VEB9

Split system air conditioners

4P456964-1C – 2018.08

3

Dry the air filter in the shadow.

4

Reattach the air filter. Align the 2 hanger brackets and push the
2 clips in their place and pull the cloth if necessary.

rear suction

bottom suction

5

Confirm that 4 hangers are fixed.

6

In case of bottom suction, close the air inlet grille.

7

Turn ON the power.

8

Press the 

FILTER SIGN RESET

 button.

Result: 

The 

TIME  TO  CLEAN  AIR  FILTER

  notification  disappears

from the user interface.

5.5

Maintenance before a long stop
period

E.g., at the end of the season.

▪ Let the indoor units run in fan only operation for about half a day in

order to dry the interior of the units.

▪ Turn  off  the  power.  The  user  interface  display  disappears.  When

the  main  power  is  turned  on,  the  air  conditioner  will  use  some
power, even if it is not operating.

▪ Clean air filters and casings of indoor units. Contact your installer

or  maintenance  person  to  clean  air  filters  and  casings  of  the
indoor  unit.  Maintenance  tips  and  procedures  for  cleaning  are
provided in the installation/operation manuals of dedicated indoor
units.  Make  sure  to  install  cleaned  air  filters  back  in  the  same
position.

5.6

Maintenance after a long stop
period

E.g., at the beginning of the season.

▪ Check  and  remove  everything  that  might  be  blocking  inlet  and

outlet vents of indoor units and outdoor units.

▪ Check if the earth is connected properly.

▪ Check if there is somewhere a broken wire. Contact your dealer in

case of problems.

▪ Clean air filters and casings of indoor units. Contact your installer

or  maintenance  person  to  clean  air  filters  and  casings  of  the
indoor  unit.  Maintenance  tips  and  procedures  for  cleaning  are
provided in the installation/operation manuals of dedicated indoor
units.  Make  sure  to  install  cleaned  air  filters  back  in  the  same
position.

▪ Turn  on  the  power  at  least  6  hours  before  operating  the  unit  in

order  to  ensure  smoother  operation.  As  soon  as  the  power  is
turned on, the user interface display appears.

6

Troubleshooting

If one of the following malfunctions occur, take the measures shown
below and contact your dealer.

WARNING

Stop  operation  and  shut  off  the  power  if  anything
unusual occurs (burning smells etc.).

Leaving  the  unit  running  under  such  circumstances  may
cause breakage, electric shock or fire. Contact your dealer.

The system MUST be repaired by a qualified service person.

Malfunction

Measure

If a safety device such as a fuse, a
breaker or an earth leakage breaker
frequently actuates or the ON/OFF
switch does NOT properly work.

Turn OFF the main power
switch.

If water leaks from the unit.

Stop the operation.

The operation switch does NOT work
well.

Turn OFF the power
supply.

If the user interface display indicates the
unit number, the operation lamp flashes
and the malfunction code appears.

Notify your installer and
report the malfunction
code.

If  the  system  does  NOT  properly  operate  except  for  the  above
mentioned cases and none of the above mentioned malfunctions is
evident,  investigate  the  system  according  to  the  following
procedures.

Malfunction

Measure

If the system does not
operate at all.

▪ Check  if  there  is  no  power  failure.  Wait

until power is restored. If a power failure
occurs  during  operation,  the  system
automatically  restarts  immediately  after
power is restored.

▪ Check if no fuse has blown or breaker is

activated.  Change  the  fuse  or  reset  the
breaker if necessary.

The system stops
immediately after
starting operation.

▪ Check  if  air  inlet  or  outlet  of  outdoor  or

indoor  unit  is  not  blocked  by  obstacles.
Remove  any  obstacles  and  make  sure
the air can flow freely.

▪ Check  if  the  air  filter  is  clogged.  Contact

your dealer to clean the air filter.

Summary of Contents for FBA100A2VEB

Page 1: ...al Split system air conditioners English Operation manual Split system air conditioners FBA35A2VEB FBA50A2VEB FBA60A2VEB FBA71A2VEB FBA100A2VEB FBA125A2VEB FBA140A2VEB FBA35A2VEB9 FBA50A2VEB9 FBA60A2VEB9 FBA71A2VEB9 ...

Page 2: ...y precautions Safety instructions that you must read before operating your system Format Paper in the box of the indoor unit Operation manual Quick guide for basic usage Format Paper in the box of the indoor unit User reference guide Detailed step by step instructions and background information for basic and advanced usage Format Digital files on http www daikineurope com support and manuals produ...

Page 3: ...on with R410A outdoor unit refer to the following table Outdoor units Cooling Heating RR71 125 15 46 C DB 18 37 C DB 12 28 C WB RQ71 125 5 46 C DB 9 21 C DB 10 15 C WB 18 37 C DB 12 28 C WB 10 27 C DB RXS35 60 10 46 C DB 15 24 C DB 16 18 C WB 18 32 C DB 10 30 C DB 3MXS40 68 4MXS68 80 5MXS90 10 46 C DB 15 24 C DB 16 18 C WB 18 32 C DB 10 30 C DB Outdoor units Cooling Heating RZQG71 140 15 50 C DB 1...

Page 4: ... may cause a reduced heating cooling effect or stop operation Turn off the main power supply switch to the unit when the unit is NOT used for longer periods of time If the main power supply switch is on the unit consumes electricity Before restarting the unit turn on the main power supply switch 6 hours before operation to ensure smooth running When the display shows time to clean the air filter c...

Page 5: ...ter if the drain pump is not used or before maintenance Insert and remove the drain plug gently Excessive force may deform the drain socket of the drain pan 1 Pull out the plug Do NOT wiggle the plug up and down a 2 Push in the plug Set the plug and push it in using a Phillips screwdriver a b a Drain plug b Phillips screwdriver 5 4 Cleaning the air filter suction grille air outlet and outside pane...

Page 6: ... operation manuals of dedicated indoor units Make sure to install cleaned air filters back in the same position Turn on the power at least 6 hours before operating the unit in order to ensure smoother operation As soon as the power is turned on the user interface display appears 6 Troubleshooting If one of the following malfunctions occur take the measures shown below and contact your dealer WARNI...

Page 7: ...uter is prepared for operation The air conditioner does not restart immediately when the temperature setting button is returned to its former position after pushing It does not restart immediately because one of its safety devices actuates to prevent the air conditioner from being overloaded The air conditioner will turn on again automatically after 3 minutes The outdoor unit has stopped This is b...

Page 8: ...s 4P456964 1C 2018 08 7 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Units MUST be treated at a specialised treatment facility for reuse recycling and recovery ...

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ...4P456964 1C 2018 08 Copyright 2017 Daikin ...

Reviews: