background image

5 Maintenance and service

Operation manual

5

FBA35~1FBA35~71A2VEB9
Split system air conditioners
4P456964-1C – 2018.08

NOTICE

Maintenance  MUST  be  done  by  an  authorized  installer  or
service agent.

We  recommend  performing  maintenance  at  least  once  a
year. However, applicable legislation might require shorter
maintenance intervals.

CAUTION

Before  accessing  terminal  devices,  make  sure  to  interrupt
all power supply.

DANGER: RISK OF ELECTROCUTION

To  clean  the  air  conditioner  or  air  filter,  be  sure  to  stop
operation  and  turn  all  power  supplies  off.  Otherwise,  an
electric shock and injury may result.

WARNING

To prevent electric shocks or fire:

▪ Do NOT rinse the unit.

▪ Do NOT operate the unit with wet hands.

▪ Do NOT place any objects containing water on the unit.

CAUTION

After  a  long  use,  check  the  unit  stand  and  fitting  for
damage. If damaged, the unit may fall and result in injury.

CAUTION

Do  NOT  touch  the  heat  exchanger  fins.  These  fins  are
sharp and could result in cutting injuries.

NOTICE

When  cleaning  the  heat  exchanger,  make  sure  to  remove
the  switch  box  and  fan  motor.  Water  or  detergent  might
deteriorate  the  insulation  of  electronic  components  and
result in burnout of these components.

WARNING

Be careful with ladders when working in high places.

5.2

To clean the drain pan

Clean the drain pan so that it does NOT become clogged and dusty.

5.3

To handle the drain pipe plug

NOTICE

▪ Do NOT remove the drain pipe plug. Water might leak

out.

▪ Use  the  drain  outlet  only  to  discharge  the  water  if  the

drain pump is not used or before maintenance.

▪ Insert  and  remove  the  drain  plug  gently.  Excessive

force may deform the drain socket of the drain pan.

1

Pull out the plug.

▪ Do NOT wiggle the plug up and down.

a

2

Push in the plug.

▪ Set the plug and push it in using a Phillips screwdriver.

a

b

a

Drain plug

b

Phillips screwdriver

5.4

Cleaning the air filter, suction
grille, air outlet and outside panels

5.4.1

To clean the air outlet and outside panels

WARNING

Do  NOT  let  the  indoor  unit  get  wet. 

Possible

consequence: 

Electric shock or fire.

NOTICE

▪ Do  NOT  use  gasoline,  benzene,  thinner  polishing

powder  or  liquid  insecticide. 

Possible  consequence:

Discoloration and deformation.

▪ Do  NOT  use  water  or  air  of  50°C  or  higher. 

Possible

consequence: 

Discoloration and deformation.

▪ Do  NOT  scrub  firmly  when  washing  the  blade  with

water. 

Possible  consequence: 

The  surface  sealing

peels off.

Clean with a soft cloth. If it is difficult to remove stains, use water or
neutral detergent.

5.4.2

To clean the air filter

When to clean the air filter

:

▪ Rule  of  thumb:  Clean  every  6  months.  If  the  air  in  the  room  is

extremely contaminated, increase the cleaning frequency.

▪ Depending  on  the  settings,  the  user  interface  can  display  the

TIME  TO  CLEAN  AIR  FILTER 

notification.  Clean  the  air  filter

when the notification is displayed.

▪ If  the  dirt  becomes  impossible  to  clean,  change  the  air  filter

(= optional equipment).

How to clean the air filter

:

1

Remove  the  air  filters  by  pulling  their  cloth  upward  (in  case  of
rear suction) or backward (in case of bottom suction).

rear suction

bottom suction

2

Clean the air filter. Use a vacuum cleaner or wash with water. If
the air filter is very dirty, use a soft brush and neutral detergent.

Summary of Contents for FBA100A2VEB

Page 1: ...al Split system air conditioners English Operation manual Split system air conditioners FBA35A2VEB FBA50A2VEB FBA60A2VEB FBA71A2VEB FBA100A2VEB FBA125A2VEB FBA140A2VEB FBA35A2VEB9 FBA50A2VEB9 FBA60A2VEB9 FBA71A2VEB9 ...

Page 2: ...y precautions Safety instructions that you must read before operating your system Format Paper in the box of the indoor unit Operation manual Quick guide for basic usage Format Paper in the box of the indoor unit User reference guide Detailed step by step instructions and background information for basic and advanced usage Format Digital files on http www daikineurope com support and manuals produ...

Page 3: ...on with R410A outdoor unit refer to the following table Outdoor units Cooling Heating RR71 125 15 46 C DB 18 37 C DB 12 28 C WB RQ71 125 5 46 C DB 9 21 C DB 10 15 C WB 18 37 C DB 12 28 C WB 10 27 C DB RXS35 60 10 46 C DB 15 24 C DB 16 18 C WB 18 32 C DB 10 30 C DB 3MXS40 68 4MXS68 80 5MXS90 10 46 C DB 15 24 C DB 16 18 C WB 18 32 C DB 10 30 C DB Outdoor units Cooling Heating RZQG71 140 15 50 C DB 1...

Page 4: ... may cause a reduced heating cooling effect or stop operation Turn off the main power supply switch to the unit when the unit is NOT used for longer periods of time If the main power supply switch is on the unit consumes electricity Before restarting the unit turn on the main power supply switch 6 hours before operation to ensure smooth running When the display shows time to clean the air filter c...

Page 5: ...ter if the drain pump is not used or before maintenance Insert and remove the drain plug gently Excessive force may deform the drain socket of the drain pan 1 Pull out the plug Do NOT wiggle the plug up and down a 2 Push in the plug Set the plug and push it in using a Phillips screwdriver a b a Drain plug b Phillips screwdriver 5 4 Cleaning the air filter suction grille air outlet and outside pane...

Page 6: ... operation manuals of dedicated indoor units Make sure to install cleaned air filters back in the same position Turn on the power at least 6 hours before operating the unit in order to ensure smoother operation As soon as the power is turned on the user interface display appears 6 Troubleshooting If one of the following malfunctions occur take the measures shown below and contact your dealer WARNI...

Page 7: ...uter is prepared for operation The air conditioner does not restart immediately when the temperature setting button is returned to its former position after pushing It does not restart immediately because one of its safety devices actuates to prevent the air conditioner from being overloaded The air conditioner will turn on again automatically after 3 minutes The outdoor unit has stopped This is b...

Page 8: ...s 4P456964 1C 2018 08 7 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Units MUST be treated at a specialised treatment facility for reuse recycling and recovery ...

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ...4P456964 1C 2018 08 Copyright 2017 Daikin ...

Reviews: