![background image](http://html2.mh-extra.com/html/daikin/faq71buv1b-x-2/faq71buv1b-x-2_technical-data-manual_4699596010.webp)
5
Wiring diagrams
3D043881
FAQ71BUV1B
A1P
Printed circuit board
HAP
Light emitting diode (service monitor green)
M1S
Motor (swing flap)
M1F
Motor (indoor fan)
R1T
Thermistor (air)
R2T
Thermistor (coil)
SS1
Selector switch (emergency)
X1M
Terminal block
X2M
Terminal block
Power supply
?
Signal receiver circuit
.
Signal transmission circuit
Infrared remote control
Receiver / display unit
A2P
Printed circuit board
A3P
Printed circuit board
BS1
Push button (on/off)
H1P
Light emitting diode (on-red)
H2P
Light emitting diode (timer-green)
H3P
Light emitting diode (filter sign-red)
H4P
Light emitting diode (defrost-orange)
SS1
Selector switch (main/sub)
SS2
Selector switch (wireless address set)
Connector for optional parts
X15A
Connector (float switch)
X35A
Connector (group control adapter)
Wired remote control
R1T
Thermistor (air)
SS1
Selector switch (main/sub)
To outdoor
unit
Note) 4
In case of simultaneous
operation system.
To
outdoor
unit
Notes
1.
D
: Terminal,
F
: Connector,
: Field wiring
2. In case using central remote control, connect it to the
unit in accordance with the attached instruction
manual.
3. Remote control model varies according to the
combination system, confirm technical materials and
catalogs, etc. before connecting.
4. X24A is connected when the infrared remote control
kit is being used.
5.
Shows short circuit connector
6. Symbols show as follows Red:red, Blk:black, Ylw:yellow,
Org:orange, Gry:gray, Prp:purple, Blu:blue
7. Confirm the method of setting the selector switch (SS1,
SS2) by installation manual and engeneering materials,
etc.
Receiver / display unit (attached to infrared remote control)
Note) 4
Indoor unit
(master)
Indoor unit
(slave)
Remote control
Norm.
Emerg.
Note) 2
Transmission wiring
connection/central remote
control
Wired remote control
Control box
SIDE
FRONT
ON/OFF input from outside
3D044228
FAQ100BUV1B
A1P
Printed circuit board
A2P
Printed circuit board
(Transformer) 230V/16V)
C1R
Capacitor (M1F)
HAP
Light emitting diode (service monitor green)
KAR
Magnetic relay (M1S)
KPR
Magnetic relay (M1P)
M1F
Motor (indoor fan)
M1S
Motor (swing flap)
Q1M
Thermo switch (M1F embedded)
R1T
Thermistor (air)
R2T
Thermistor (coil)
S1Q
Limit switch (swing flap)
SS1
Selector switch (emergency)
V1TR
Phase control circuit
X1M
Terminal block
X2M
Terminal block
?
Signal receiver circuit
.
Signal transmission circuit
Wired remote control
R1T
Thermistor (air)
SS1
Selector switch (main/sub)
Infrared remote control
Receiver / display unit
A3P
Printed circuit board
A4P
Printed circuit board
BS1
Push button (on/off)
H1P
Light emitting diode (on-red)
H2P
Light emitting diode (timer-green)
H3P
Light emitting diode (filter sign-red)
H4P
Light emitting diode (defrost-orange)
SS1
Selector switch (main/sub)
SS2
Selector switch (wireless address set)
Connector for optional parts
X15A
Connector (float switch)
X25A
Connector (drain pump)
X35A
Connector (group control adapter)
X16A
X61A
Connector (interface adapter for sky air series)
To outdoor
unit
Note) 4
Wired remote
control
Control box
In case of simultaneous
operation system.
To
outdoor
unit
Notes
1.
D
: Terminal
F
,
: Connector
2.
: Field wiring
3. In case using central remote control, connect it to
the unit in accordance with the attached
instruction manual.
4. X24A is connected when the infrared remote
control kit is being used.
5. Remote control model varies according to the
combination system, confirm technical materials
and catalogs, etc. before connecting.
6. Symbols show as follows Red:red, Blk:black,
Ylw:yellow, Org:orange, Gry:gray, Prp:purple,
Blu:blue
7. Confirm the method of setting the selector
switch (SS1, SS2) by installation manual and
engeneering materials, etc.
8. x15A, x25A are connected when the drain up kit
is being used. Connect it to the kit in accordance
with the attached installation manual.
Receiver / display unit
Note) 4
Indoor unit
(master)
Indoor unit
(slave)
Infrared remote
control
Emerg.
Norm.
Note) 8
•
Wall Mounted, Inverter Controlled Unit
•
R-410A
•
FAQ71-100BUV1B
1
5
8
•
Split - Sky Air
•
Indoor Units