background image

1

Features

+

Ideal for shops, restaurants or offices requiring maximum floor

space for furniture and fittings

+

The 71 class has a modern casing: it is very compact (290mm

height - 1050mm width) and very lightweight (only 13 kg).

+

Fits neatly on a wall

+

Automatic air flow director ensures uniform air flow and

temperature distribution

+

The flap of the unit is closed when not operating.

+

The front panel of the new casing is easy removable and

washable.

+

Extremely quiet in operation both indoors and outdoors

+

For equal distribution in larger rooms, up to 3 indoor units can

be connected to 1 outdoor. They are operated from 1 remote

control

+

These indoor units can also be connected to the Sky Air super

inverter RZQ-B.

+

Daikin remote controls give you easy control at your fingertips.

+

The wired remote control provides you with a schedule timer,

enabling to program the air conditioning daily or weekly.

+

The optional remote ON/OFF enables you to start/stop the air

conditioning from a mobile phone via a telephone remote

control (field supply).

+

The optional forced OFF enables you to switch off the unit

automatically. E.g. when a window is opened, the unit switches

off.

+

The ’home leave’ operation button prevents large temperature

differences by continuously operating at a minimum (heating

mode) or maximum (cooling mode) preset level while you’re

out or sleeping. It also allows the indoor temperature to return

quickly to your favourite comfort level.

2 1 3

0

8 q x

6

) (

6

Optional

Optional

Heat pump

2 steps

Optional

Twin / Triple

Wall Mounted, Inverter Controlled Unit

R-410A

FAQ71-100BUV1B

1

1

2

Split - Sky Air

Indoor Units

Summary of Contents for FAQ71BUV1B x 2

Page 1: ...FAQ BU Wall Mounted Unit technical data Split Sky Air air conditioning systems...

Page 2: ...vironment Daikin Europe N V is approved by LRQA for its Quality Management System in accordance with the ISO9001 standard ISO9001 pertains to quality assurance regarding design development manufacturi...

Page 3: ...5 Wiring diagrams 8 6 Sound level 10 Sound level data Sound pressure spectrum 7 Air flow patterns 11 8 Accessories 15 Standard accessories Optional accessories 9 Control systems 16 10 Safety device s...

Page 4: ...RZQ B Daikin remote controls give you easy control at your fingertips The wired remote control provides you with a schedule timer enabling to program the air conditioning daily or weekly The optional...

Page 5: ...1B RQ100B7V3B RQ100B7W1B NOMINAL CAPACITY 3 Cooling 1 nominal kW 7 10 10 10 Heating 2 nominal kW 8 00 11 20 NOMINAL INPUT Cooling nominal kW 2 65 2 53 3 56 3 52 Heating nominal kW 2 58 2 49 3 96 3 82...

Page 6: ...19 Speed steps 2 steps Type Cross flow fan Qty x motor output W 1 x 43 1 x 49 HEAT EXCHANGER Type Cross fin coil Multi louver fins and Hi XA tubes Rows x stages x fin pitch mm 2 x 16 x 1 4 2 x 12 x 1...

Page 7: ...1 V1 NOMINAL DISTRIBUTION SYSTEM VOLTAGE Phase 1 1 Frequency Hz 50 50 Voltage V 220 240 220 240 4D043953 NOTES 1 Nominal cooling capacities are based on indoor temperature 27 CDB 19 5 CWB outdoor temp...

Page 8: ...n Required space unit mm 50 or more 250 or more Required space J80 hole approx 450 approx 600 FAQ100BUV1B 8 5x20 Oval hole for wood screw Mounting location Detail j A Mounting hole for installation pl...

Page 9: ...ed pipe Indoor heat exchanger Field piping J9 5 C1220T 0 4D037995A FAQ71 100BUV1B Field piping J15 9 C1220T 0 Refrigerant pipe connection port diameters Model A B FAQ71 100BUV1B J 9 5 J 15 9 To outdoo...

Page 10: ...t board Transformer 230V 16V C1R Capacitor M1F HAP Light emitting diode service monitor green KAR Magnetic relay M1S KPR Magnetic relay M1P M1F Motor indoor fan M1S Motor swing flap Q1M Thermo switch...

Page 11: ...tch for safety 6 All field wiring and components must be provided by a licensed electrician 7 The unit shall be grounded in compilance with the applicable local and national codes 8 Wiring shown are g...

Page 12: ...UV1B Cooling FAQ100BUV1B Heating Octave band sound pressure level Octave band sound pressure level 4D027787A 4D027790A Octave band center frequency Hz Octave band center frequency Hz approximate thres...

Page 13: ...air velocity distribution Air flow direction 10 downward FAQ71BUV1B Cooling air temperature distribution Air flow direction 10 downward 4D039573A Wall Mounted Inverter Controlled Unit R 410A FAQ71 100...

Page 14: ...ion Air flow direction 65 C downward FAQ71BUV1B Heating air temperature distribution Air flow direction 65 C downward 4D039574A Wall Mounted Inverter Controlled Unit R 410A FAQ71 100BUV1B 7 Air flow p...

Page 15: ...ution Air flow direction 10 downward FAQ100BUV1B Cooling air temperature distribution Air flow direction 10 downward 4D028547A Wall Mounted Inverter Controlled Unit R 410A FAQ71 100BUV1B 7 Air flow pa...

Page 16: ...ion Air flow direction 65 C downward FAQ100BUV1B Heating air temperature distribution Air flow direction 65 C downward 4D028548A Wall Mounted Inverter Controlled Unit R 410A FAQ71 100BUV1B 7 Air flow...

Page 17: ...W Wiring adapter for electrical appendices 2 KRP4A51 Installation box for adapter PCB KRP4A93 Central remote control DCS302C51 Electrical box with earth terminal 3 blocks KJB311A Unified ON OFF contro...

Page 18: ...emote control 6 5 x 9 Round end slit Cover open Cover closed 5 x 7 Round end slit HoleJ5 5 x 10 Round end slit 3TW23651 2 BRC1D527 Wall Mounted Inverter Controlled Unit R 410A FAQ71 100BUV1B 1 9 9 1 1...

Page 19: ...ndoor unit j b Outdoor unit j c Infrared remote control j d Inlet air j e Discharged air j f Air outlet j g Air flow flap at air outlet j h Refrigerant piping connection electric wire j i Drain pipe j...

Reviews: