background image

3

English

Do not place items that might be damaged by 
water under the indoor unit.

Water may condensate and drip if the humidity 
reaches 80% or if the drain exit gets clogged.

Do not place a burner or heater at a place 
directly exposed to the wind from the air con-
ditioner.

Incomplete combustion of the burner or heater 
may result.

Do not allow a child to mount on the outdoor 
unit or avoid placing any object on it.

Falling or tumbling may result in injury.

Do not expose animals and plants directly to 
the wind.

Adverse influence to animals and plants may result.

Do not wash the air conditioner with water.

Electric shock or fire may result.

Do not install the air conditioner at any place 
where flammable gas may leak out.

If the gas leaks out and stays around the air con-
ditioner, a fire may break out.

Be sure to install an earth leakage breaker.

Unless it is installed, electric shock or fire may 
result.

Be sure the air conditioner is electrically 
grounded.

Do not connect the grounding conductor to a gas 
pipe, water pipe, lightning arrester, and the 
grounding conductor for a telephone. 
Imperfect grounding work may result in an elec-
tric shock.

Execute complete drain piping for perfect 
drainage.

Incomplete piping may result in a water leakage.

The appliance is not intended for use by 
young children or infirm persons without 
supervision.
Young children should be supervised to 
ensure that they do not play with the appliance.

If the temperature or the humidity is beyond the fol-
lowing conditions, safety devices may work and the 
air conditioner may not operate, or sometimes, 
water may drop from the indoor unit.

COOLING

3. OPERATION RANGE

OUTDOOR 

UNIT

INDOOR

OUTDOOR 

TEMPERATURE 

TEMPERA-

TURE

HUMIDITY

RZQ71

DB

18 to 37

80% or 

below

DB

–15 to 50

WB 12 to 28

HEATING

D

 

B: Dry bulb temperature

WB: Wet bulb temperature

The setting temperature range of the remote con-
troller is 16°C to 32°C.

Regarding places for installation

• Is the air conditioner installed at a well-venti-

lated place where there are no obstacles 
around?

• Do not use the air conditioner in the following 

places.

a.Filled with much mineral oil such as cutting oil
b.Where there is much salt such as a beach area
c.Where sulfured gas exists such as a hot-spring 

resort

d.Where there are considerable voltage fluctua-

tions such as a factory or plant

e.Vehicles and vessels

 

f

 

.Where there is much spray of oil and vapor such 

as a cookery, etc.

g.Where there are machines generating electro-

magnetic waves

h.Filled with acid and/or alkaline steam or vapor

• Is a snow protection measure taken?

For details, consult your dealer.

Regarding wiring

• All wiring must be performed by an authorized 

electrician.

To do wiring, ask your dealer. Never do it by yourself.

• Make sure that a separate power supply cir-

cuit is provided for this air conditioner and 
that all electrical work is carried out by quali-
fied personnel according to local laws and 
regulations.

Pay attention to running noises, too

• Are the following places selected?

a.A place that can sufficiently withstand the 

weight of the air conditioner with less running 
noises and vibrations.

b.A place where the hot wind discharged from the air 

outlet of the outdoor unit and the running noises.

OUTDOOR UNIT

INDOOR 

OUTDOOR 

TEMPERATURE

TEMPERATURE

RZQ71 DB

10 

to 

27

DB

–19.5 to 21

WB

–20 to 15.5

4. INSTALLATION SITE

01_EN_3PN05140-5E.fm  Page 3  Friday, December 5, 2003  11:15 AM

Summary of Contents for FAQ71BUV1B x 2

Page 1: ...IT SYSTEM Air Conditioner OPERATION MANUAL MODELS Wall mounted type FAQ71BUV1B English Deutsch Fran ais Espa ol Italiano Nederlands Portugues Russian Cover TOP fm Page 1 Thursday December 11 2003 5 01...

Page 2: ...sed as simultaneous operation system PRECAUTIONS FOR GROUP CONTROL SYSTEM OR TWO REMOTE CONTROLLER CONTROL SYSTEM This system provides two other control systems beside individual control one remote co...

Page 3: ...s to be installed in a small room it is necessary to take proper mea sures so that the amount of any leaked refriger ant does not exceed the limiting concentration even when it leaks If the refrigeran...

Page 4: ...drop from the indoor unit COOLING 3 OPERATION RANGE OUTDOOR UNIT INDOOR OUTDOOR TEMPERATURE TEMPERA TURE HUMIDITY RZQ71 DB 18 to 37 80 or below DB 15 to 50 WB 12 to 28 HEATING DB Dry bulb temperature...

Page 5: ...y shows After 6 to 8 minutes maximum 10 minutes of DEFROST OPERATION the system returns to HEATING OPERATION 5 OPERATION PROCEDURE Regarding outside air temperature and heat ing capacity The heating c...

Page 6: ...position where adjustments are possible Your hand may get caught if you attempt to make adjustments while the unit is swinging Observe the following precautions to ensure the system operates Adjust t...

Page 7: ...VICE PERSONNEL B Washing with water When the air filter is very dirty use soft brush and neutral detergent Remove water and dry in the shade NOTE Do not wash the air conditioner with hot water of more...

Page 8: ...s tem is not operating Turn off the main power supply switch for saving energy The display on the remote controller will vanish when the main power switch is turned off Clean the air filter and the ex...

Page 9: ...mmediately after the stop of DEFROST OPERATION This is the noise of refrigerant caused by flow stop and flow change A continuous flow Shah sound is heard when the system is in COOLING OPERATION or at...

Page 10: ...NANCE 3 The system operates but it does not suffi ciently cool or heat If the air inlet or outlet of the indoor or the out door unit is blocked with obstacles Remove the obstacle and make it well vent...

Page 11: ...3PN05140 5E EM03A090 0401 HT Cover 1 fm Page 1 Friday December 5 2003 11 13 AM...

Reviews: