Measure:

 Notify your Daikin dealer and inform 

him/her of the display.

II. If the system does not properly operate except 

for the above mentioned case, and none of the 
above mentioned malfunctions is evident, 
investigate the system according to the fol-
lowing procedures.

1. If the system does not operate at all.

Check if there is a power failure.
Wait until power is restored. If power failure 
occurs during operation, the system automati-
cally restarts immediately after the power sup-
ply recovers.

Check if the fuse has blown or breaker has 
worked. 
Change the fuse or set the breaker.

2. If the system stops operating after operating 

the system.

Check if the air inlet or outlet of outdoor or 
indoor unit is blocked by obstacles.
Remove the obstacle and make it well-venti-
lated.

Check if the air filter is clogged.
Ask a qualified service person to clean the air 
filters (Refer to MAINTENANCE).

3. The system operates but it does not suffi-

ciently cool or heat.

If the air inlet or outlet of the indoor or the out-
door unit is blocked with obstacles.
Remove the obstacle and make it well-venti-
lated. 

If the air filter is clogged.
Ask a qualified service person to clean the air 
filters (Refer to MAINTENANCE).

If the set temperature is not proper (Refer to 
ADJUSTMENT).

If the FAN SPEED button is set to LOW 
SPEED (Refer to ADJUSTMENT).

OPERATION lamp

INSPECTION 
display

MALFUNCTION 
CODE

INDOOR UNIT 
No. in which a 
malfunction occurs

UNIT   No.

C

L

  H     

If the air flow angle is not proper (Refer to AIR 
FLOW DIRECTION ADJUST).

If the doors or the windows are open. Shut 
doors or windows to prevent wind from coming 
in.

If direct sunlight enters the room (when cool-
ing).
Use curtains or blinds.

When there are too many inhabitants in the 
room (when cooling).
Cooling effect decreases if heat gain of the 
room is too large.

If the heat source of the room is excessive 
(when cooling).
Cooling effect decreases if heat gain of the 
room is too large.

01_EN_3PN05140-5E.fm  Page 9  Friday, December 5, 2003  11:15 AM

Summary of Contents for FAQ71BUV1B x 2

Page 1: ...IT SYSTEM Air Conditioner OPERATION MANUAL MODELS Wall mounted type FAQ71BUV1B English Deutsch Fran ais Espa ol Italiano Nederlands Portugues Russian Cover TOP fm Page 1 Thursday December 11 2003 5 01...

Page 2: ...sed as simultaneous operation system PRECAUTIONS FOR GROUP CONTROL SYSTEM OR TWO REMOTE CONTROLLER CONTROL SYSTEM This system provides two other control systems beside individual control one remote co...

Page 3: ...s to be installed in a small room it is necessary to take proper mea sures so that the amount of any leaked refriger ant does not exceed the limiting concentration even when it leaks If the refrigeran...

Page 4: ...drop from the indoor unit COOLING 3 OPERATION RANGE OUTDOOR UNIT INDOOR OUTDOOR TEMPERATURE TEMPERA TURE HUMIDITY RZQ71 DB 18 to 37 80 or below DB 15 to 50 WB 12 to 28 HEATING DB Dry bulb temperature...

Page 5: ...y shows After 6 to 8 minutes maximum 10 minutes of DEFROST OPERATION the system returns to HEATING OPERATION 5 OPERATION PROCEDURE Regarding outside air temperature and heat ing capacity The heating c...

Page 6: ...position where adjustments are possible Your hand may get caught if you attempt to make adjustments while the unit is swinging Observe the following precautions to ensure the system operates Adjust t...

Page 7: ...VICE PERSONNEL B Washing with water When the air filter is very dirty use soft brush and neutral detergent Remove water and dry in the shade NOTE Do not wash the air conditioner with hot water of more...

Page 8: ...s tem is not operating Turn off the main power supply switch for saving energy The display on the remote controller will vanish when the main power switch is turned off Clean the air filter and the ex...

Page 9: ...mmediately after the stop of DEFROST OPERATION This is the noise of refrigerant caused by flow stop and flow change A continuous flow Shah sound is heard when the system is in COOLING OPERATION or at...

Page 10: ...NANCE 3 The system operates but it does not suffi ciently cool or heat If the air inlet or outlet of the indoor or the out door unit is blocked with obstacles Remove the obstacle and make it well vent...

Page 11: ...3PN05140 5E EM03A090 0401 HT Cover 1 fm Page 1 Friday December 5 2003 11 13 AM...

Reviews: