background image

SPLIT SYSTEM

Air Conditioner

OPERATION MANUAL

MODELS

(Wall mounted type)

FAQ71BUV1B

English

Deutsch

Français

Español

Italiano

Ελληνικ

Ü

Nederlands

Portugues

Russian

Cover TOP.fm  Page 1  Thursday, December 11, 2003  5:01 PM

Summary of Contents for FAQ71BUV1B x 2

Page 1: ...IT SYSTEM Air Conditioner OPERATION MANUAL MODELS Wall mounted type FAQ71BUV1B English Deutsch Fran ais Espa ol Italiano Nederlands Portugues Russian Cover TOP fm Page 1 Thursday December 11 2003 5 01...

Page 2: ...sed as simultaneous operation system PRECAUTIONS FOR GROUP CONTROL SYSTEM OR TWO REMOTE CONTROLLER CONTROL SYSTEM This system provides two other control systems beside individual control one remote co...

Page 3: ...s to be installed in a small room it is necessary to take proper mea sures so that the amount of any leaked refriger ant does not exceed the limiting concentration even when it leaks If the refrigeran...

Page 4: ...drop from the indoor unit COOLING 3 OPERATION RANGE OUTDOOR UNIT INDOOR OUTDOOR TEMPERATURE TEMPERA TURE HUMIDITY RZQ71 DB 18 to 37 80 or below DB 15 to 50 WB 12 to 28 HEATING DB Dry bulb temperature...

Page 5: ...y shows After 6 to 8 minutes maximum 10 minutes of DEFROST OPERATION the system returns to HEATING OPERATION 5 OPERATION PROCEDURE Regarding outside air temperature and heat ing capacity The heating c...

Page 6: ...position where adjustments are possible Your hand may get caught if you attempt to make adjustments while the unit is swinging Observe the following precautions to ensure the system operates Adjust t...

Page 7: ...VICE PERSONNEL B Washing with water When the air filter is very dirty use soft brush and neutral detergent Remove water and dry in the shade NOTE Do not wash the air conditioner with hot water of more...

Page 8: ...s tem is not operating Turn off the main power supply switch for saving energy The display on the remote controller will vanish when the main power switch is turned off Clean the air filter and the ex...

Page 9: ...mmediately after the stop of DEFROST OPERATION This is the noise of refrigerant caused by flow stop and flow change A continuous flow Shah sound is heard when the system is in COOLING OPERATION or at...

Page 10: ...NANCE 3 The system operates but it does not suffi ciently cool or heat If the air inlet or outlet of the indoor or the out door unit is blocked with obstacles Remove the obstacle and make it well vent...

Page 11: ...3PN05140 5E EM03A090 0401 HT Cover 1 fm Page 1 Friday December 5 2003 11 13 AM...