background image

EWAQ+EWYQ005~007ADVP
Packaged air-cooled water chillers and 
packaged reversible air to water heat pumps
4PW71885-1 – 10.2011

Operation manual

6

2.6.2.

Programming

Programming cooling or heating

Programming cooling or heating is carried out as follows.

1

Use the 

=

 button to select the operation mode (cooling or

heating) you want to program.

2

Press the 

<

 button.

The actual mode is blinking.

3

Use the 

pi

 and 

pj

 buttons to select the mode (current

mode or quiet mode) you want to program.

The selected mode is blinking.

You can leave programming by pressing the 

pr

 button.

To program quiet mode, refer to 

" Programming quiet mode" on

page 7

.

4

Press the 

<

 button to confirm the selected mode.

The selected day is blinking.

5

Select the day you would like to consult or to program by means
of the 

pi

 and 

pj

 buttons.

The selected day is blinking.

You can return to step 

3

 by pressing the 

pr

 button.

6

Press the 

<

 button to confirm the selected day.

The first programmed action of the selected day appears.

7

Use the 

pi

 and 

pj

 buttons to consult the other

programmed actions of that day.

This is called the readout mode. Empty program actions (e.g. 4
and 5) are not displayed. 

You can return to step 

5

 by pressing the 

pr

 button.

8

Press the 

<

 button for 5 seconds to enter the programming

mode.

You can return to step 

7

 by pressing the 

pr

 button.

9

Use the 

<

 button to select the action number you would like to

program or to modify.

10

Use the 

ba

 button to select:

-

x

: to switch both cooling or heating and the controller off.

-

9

: set the temperature by means of the 

bi

 and 

bj

 buttons.

-

a

: to select automatic temperature calculation (only in 

heating mode). You can change the shift value by means of 
the 

bi

 and 

bj

 buttons.

11

Use the 

pi

 and 

pj

 buttons to set the correct action time.

12

Repeat steps 

9

 to 

11

 to program the other actions of the

selected day.

When all actions have been programmed, make sure that the
display shows the highest action number you would like to save.

13

Press the 

<

 button for 5 seconds to store the programmed

actions. Actions are stored only after 

$

 is displayed for

1 second.

If the 

<

 button is pressed when action number 3 is displayed,

actions 1, 2 and 3 are stored but 4 and 5 are deleted.

You automatically return to step 

7

. By pressing the 

pr

 button

several times, you return to previous steps in this procedure and
finally return to normal operation.

NOTE

Programming cooling or heating are both done in the
same way. At the start of the programming procedure
cooling or heating operation is selected. After that, you
have to return to the start of the programming
procedure to program the other operation mode.

As mentioned in 

"2.6.1. Getting started" on page 5

,

adjust both heating and cooling setpoints for each
programmed action. Otherwise, default setpoints will
be used.

5 sec

5 sec

SAVE NO SAVE

NOTE

Returning to previous steps in the programming
procedure without saving modified settings is done by
pressing the 

pr

 button.

Summary of Contents for EWAQ005ADVP

Page 1: ...OPERATION MANUAL EWAQ005ADVP EWAQ006ADVP EWAQ007ADVP EWYQ005ADVP EWYQ006ADVP EWYQ007ADVP Packaged air cooled water chillers and packaged reversible air to water heat pumps...

Page 2: ...The safety valve which prevents the pressure in the closed water circuit from exceeding 3 bar 2 OPERATING THE DIGITAL CONTROLLER Operating the unit comes down to operating the digital controller 2 1...

Page 3: ...ve 15 COMPRESSOR ICON This icon indicates that the compressor in the outdoor unit of the installation is active 16 PUMP ICON This icon indicates that the circulation pump is active 17 OUTDOOR TEMPERAT...

Page 4: ...4 or according to the defrost demand from the outdoor unit Defrost d d d d In heating operation freezing of the outdoor heat exchanger may occur due to low outdoor temperature If this risk occurs the...

Page 5: ...ill regain control over the installation as soon as the next programmed command of the schedule timer occurs The schedule timer is enabled p icon displayed or disabled p icon not displayed by pressing...

Page 6: ...r the first action and end with the highest number for the last action This is not a requirement but will simplify the interpretation of the program later If 2 or more actions are programmed for the s...

Page 7: ...umber you would like to program or to modify 10 Use the ba button to select x to switch both cooling or heating and the controller off 9 set the temperature by means of the bi and bj buttons a to sele...

Page 8: ...g the pr button To consult quiet mode refer to Consulting quiet mode actions on page 7 3 Press the button to confirm the selected mode The actual day is blinking 4 Select the day you would like to con...

Page 9: ...975 1 GWP global warming potential Periodical inspections for refrigerant leaks may be required depending on European or local legislation Please contact your local dealer for more information 3 2 Mai...

Page 10: ......

Page 11: ......

Page 12: ...4PW71885 1 10 2011 Copyright 2011 Daikin...

Reviews: