7
|
Unit installation
Installer reference guide
59
EPRA14~W1 + ET9W
Daikin Altherma 3 H HT F
4P644739-1 – 2021.02
NOTICE
Level.
Make sure the unit is level. Recommended:
Use 4 sets of M12 anchor bolts, nuts and washers. Provide at least 150 mm of free
space below the unit. Additionally, make sure the unit is positioned at least
100 mm above the maximum expected level of snow.
Anchor points
800
(mm)
479
Pedestal
When installing on a pedestal, make sure that the discharge grille still can be put in
its safety position. See
"7.3.7 To remove the discharge grille, and put the grille in
63].
800
479
a
≥150
(mm)
4× M12
a
Make sure not to cover the drain hole in the bottom plate of the unit.
7.3.4 To install the outdoor unit
1
Carry the unit by its slings, and put it onto the installation structure.
Summary of Contents for ETVZ16S18EA6V
Page 270: ...12 12...
Page 271: ......
Page 272: ...4P644739 1 2021 02 Copyright 2021 Daikin Verantwortung f r Energie und Umwelt...