4 Unit installation
Installation manual
6
ELSH/X(B)12P30+50E
Daikin Altherma 3 R MT ECH
₂
O
4P708484-1 – 2023.03
CAUTION
Install the indoor unit at a minimum distance of 1 m from
other heat sources (>80°C) (e.g. electrical heater, oil
heater, chimney) and combustible materials. Otherwise the
unit may be damaged or in extreme cases catch fire.
≥500
00
1≥
≥100
08
4≥
[
]
mm
a
b
a
≥100
a+b
≥600
b
≥300
INFORMATION
Serviceability may be impacted, if the indicated clearances
cannot be maintained.
INFORMATION
If you have limited installation space, do the following
before installing the unit in its final position:
connect the drain hose to the drain"
4.1.2
Special requirements for R32 units
Additionally to the spacing guidelines: Because the total refrigerant
charge in the system is ≥1.84 kg, the room where you install the
indoor unit must also comply with the conditions described in
7].
WARNING
▪ Do NOT pierce or burn refrigerant cycle parts.
▪ Do NOT use means to accelerate the defrosting
process or to clean the equipment, other than those
recommended by the manufacturer.
▪ Be aware that R32 refrigerant does NOT contain an
odour.
WARNING
The appliance shall be stored so as to prevent mechanical
damage and in a well-ventilated room without continuously
operating ignition sources (example: open flames, an
operating gas appliance or an operating electric heater)
and have a room size as specified below.
NOTICE
▪ Do NOT re-use joints and copper gaskets which have
been used already.
▪ Joints made in installation between parts of refrigerant
system shall be accessible for maintenance purposes.
WARNING
Make sure installation, servicing, maintenance and repair
comply with instructions from Daikin and with applicable
legislation and are executed ONLY by authorised persons.
NOTICE
▪ Protect pipework from physical damage.
▪ Keep the pipework installation to a minimum.