4 Unit installation
Installation manual
12
ELSH/X(B)12P30+50E
Daikin Altherma 3 R MT ECH
₂
O
4P708484-1 – 2023.03
Table 3: Maximum chimney length
When installing a chimney, the chimney length must be less than the maximum chimney length.
• Use the columns with the correct refrigerant charge. For intermediate refrigerant charges, use the columns with the higher value.
Example:
If
the refrigerant charge is 3.5 kg, use the columns of 4.05 kg.
• For intermediate diameters, use the column with the lower value.
Example:
If the diameter is 23 mm, use the column of 22 mm.
• X: Not allowed
Maximum chimney length (m) – In case of Refrigerant charge=3.25 kg (and T=60°C)
In case of Refrigerant charge=4.05 kg (and T=60°C)
Chimney
Inside diameter of chimney (mm)
Inside diameter of chimney (mm)
20 mm
22 mm
24 mm
26 mm
28 mm
20 mm
22 mm
24 mm
26 mm
28 mm
Straight pipe
24.41 m
42.18 m
67.50 m
102.40 m
149.26 m
13.28 m
24.78 m
41.27 m
64.11 m
94.87 m
1× 90° elbow
22.61 m
40.20 m
65.34 m
100.06 m
146.74 m
11.48 m
22.80 m
39.11 m
61.77 m
92.35 m
2× 90° elbow
20.81 m
38.22 m
63.18 m
97.72 m
144.22 m
9.68 m
20.82 m
36.95 m
59.43 m
89.83 m
3× 90° elbow
19.01 m
36.24 m
61.02 m
95.38 m
141.70 m
7.88 m
18.84 m
34.79 m
57.09 m
87.31 m
Table 4: Minimum bottom opening area for natural ventilation
Take the following into account:
• Use the correct table. For intermediate refrigerant charges, use the table with the higher value.
Example:
If the refrigerant charge is 3.5 kg,
use the table of 3.65 kg.
• For intermediate floor areas, use the column with the lower value.
Example:
If the floor area is 7.25 m², use the column of 6.00 m².
• For intermediate release height values, use the row with the lower value.
Example:
If the release height is 1.95 m, use the row of 1.90 m.
• A
nv
: Bottom opening area for natural ventilation.
• A
nv-min
: Minimum bottom opening area for natural ventilation.
• (*): Already OK (no ventilation openings needed).
A
nv-min
(dm²) – In case of Refrigerant charge=3.25 kg
Release height (m)
Floor area of room A (m²) [! NOT room A + room B !]
4.00 m²
6.00 m²
8.00 m²
10.00 m²
12.00 m²
14.00 m²
16.00 m²
1.89 m
3.437 dm²
1.453 dm²
0.473 dm²
(*)
(*)
(*)
(*)
1.90 m
3.410 dm²
1.421 dm²
0.436 dm²
(*)
(*)
(*)
(*)
2.00 m
3.120 dm²
1.079 dm²
0.043 dm²
(*)
(*)
(*)
(*)
2.20 m
2.585 dm²
0.445 dm²
(*)
(*)
(*)
(*)
(*)
2.40 m
2.103 dm²
(*)
(*)
(*)
(*)
(*)
(*)
2.60 m
1.662 dm²
(*)
(*)
(*)
(*)
(*)
(*)
2.80 m
1.257 dm²
(*)
(*)
(*)
(*)
(*)
(*)
3.00 m
0.881 dm²
(*)
(*)
(*)
(*)
(*)
(*)
A
nv-min
(dm²) – In case of Refrigerant charge=3.65 kg
Release height (m)
Floor area of room A (m²) [! NOT room A + room B !]
4.00 m²
6.00 m²
8.00 m²
10.00 m²
12.00 m²
14.00 m²
16.00 m²
1.89 m
4.349 dm²
2.364 dm²
1.446 dm²
0.601 dm²
(*)
(*)
(*)
1.90 m
4.319 dm²
2.330 dm²
1.407 dm²
0.558 dm²
(*)
(*)
(*)
2.00 m
4.006 dm²
1.965 dm²
0.989 dm²
0.092 dm²
(*)
(*)
(*)
2.20 m
3.430 dm²
1.290 dm²
0.214 dm²
(*)
(*)
(*)
(*)
2.40 m
2.912 dm²
0.676 dm²
(*)
(*)
(*)
(*)
(*)
2.60 m
2.440 dm²
0.113 dm²
(*)
(*)
(*)
(*)
(*)
2.80 m
2.006 dm²
(*)
(*)
(*)
(*)
(*)
(*)
3.00 m
1.605 dm²
(*)
(*)
(*)
(*)
(*)
(*)
A
nv-min
(dm²) – In case of Refrigerant charge=4.05 kg
Release height (m)
Floor area of room A (m²) [! NOT room A + room B !]
4.00 m²
6.00 m²
8.00 m²
10.00 m²
12.00 m²
14.00 m²
16.00 m²
1.89 m
5.260 dm²
3.276 dm²
2.419 dm²
1.630 dm²
0.828 dm²
0.022 dm²
(*)
1.90 m
5.229 dm²
3.240 dm²
2.378 dm²
1.585 dm²
0.779 dm²
(*)
(*)
2.00 m
4.892 dm²
2.852 dm²
1.936 dm²
1.093 dm²
0.241 dm²
(*)
(*)
2.20 m
4.276 dm²
2.135 dm²
1.117 dm²
0.180 dm²
(*)
(*)
(*)
2.40 m
3.721 dm²
1.485 dm²
0.371 dm²
(*)
(*)
(*)
(*)
2.60 m
3.217 dm²
0.890 dm²
(*)
(*)
(*)
(*)
(*)
2.80 m
2.755 dm²
0.340 dm²
(*)
(*)
(*)
(*)
(*)
3.00 m
2.328 dm²
(*)
(*)
(*)
(*)
(*)
(*)