background image

6 Installation

Installation manual

4

EKRTETS

Room thermostat

4P677092-1 – 2021.10

7

Cover up the cutout holes with electrical tape (field supply).

8

Insert the included batteries in the battery compartments.

9

Close the battery compartments.

Result: 

The room thermostat is ready for use.

Tabletop installation

You  can  only  use  the  thermostat  as  a  tabletop  solution  when  the
external temperature sensor is NOT installed. In this case, the room
thermostat functions as a completely wireless unit and can be put in
its holder anywhere in the house.

10

Open  the  battery  compartments  and  remove  the  battery
insulators.

11

Insert the included batteries in the battery compartments.

12

Put the room thermostat into its holder.

Result: 

The room thermostat is ready for use.

6.2

To install the receiver

WARNING

Before  obtaining  access  to  terminals,  all  power  circuits
MUST be interrupted.

WARNING

Water  entering  the  receiver  may  cause  an  electric  leak  or
may damage the internal electronic parts.

Prerequisite: 

You have considered the installation site requirements

for  the  receiver  when  selecting  the  installation  location.  See

"5.1 Installation site requirements"

 [

4

 3] for more information.

1

Drill holes in the wall, taking into account the dimensions of the
receiver.

2

Insert the supplied plugs in the holes.

3

Fasten the receiver to the wall with the supplied screws.

4

Unscrew the front cover screws of the receiver and remove the
front cover.

5

Unscrew  both  screws  of  the  lower  right  cable  bracket  and
remove the bracket.

6

According to your application, perform the wiring:

WARNING

All  field  wiring  and  components  MUST  be  installed  by  a
licensed  electrician  and  MUST  comply  with  the  applicable
legislation.

Unit

Refer  to  the  wiring  diagram  or  the  addendum  book  for  optional
equipment  of  the  unit.  Use  a  wire  size  between  0.75  mm

2

  and

1.50 mm

2

. Example unit:

EKRTRB

H

Heating demand

C

Cooling demand

Motorised valve

Wire the motorised valve and the receiver as shown below (heating
only applications). Use a wire size between 0.75 mm

2

 and 1.50 mm

2

.

EKRTRB

1N~50 Hz

250 VAC

1N~50 Hz

250 VAC

H

Heating demand

C

Cooling demand

Summary of Contents for EKRTRB

Page 1: ...Installation manual Room thermostat English Installation manual Room thermostat EKRTRB EKRTETS...

Page 2: ...2M and select a power cable that is in accordance with applicable legislation WARNING A main switch or other means for disconnection having a contact separation in all poles MUST be incorporated in th...

Page 3: ...pically close the indoor unit The receiver is designed to be installed in a vertical orientation only Do NOT install the receiver in metal boxes or near vertical metal pipes and electronic circuits Mo...

Page 4: ...e the internal electronic parts Prerequisite You have considered the installation site requirements for the receiver when selecting the installation location See 5 1 Installation site requirements 43...

Page 5: ...the temperature sensor wiring to the room thermostat as described in 6 1 To install the room thermostat 43 4 On the room thermostat set the value for parameter 20 rEGU to FLR in the installer menu For...

Page 6: ...7 C Range 20 C 37 C Parameter Description Possible values a Name 33 Win Open window detection function yes enabled no disabled 34 rH Humidity threshold value 55 Range 0 100 35 dEv Dew prevention funct...

Page 7: ...oling Humidity percentage threshold You can set a threshold value for the humidity percentage Whenever the room thermostat detects that the humidity percentage exceeds the set threshold cooling demand...

Page 8: ...4P677092 1 2021 10 Copyright 2021 Daikin 4P677092 1 0000000T Verantwortung f r Energie und Umwelt...

Reviews: