background image

 

E260A + EK260AA

 

Domestic hot water tank for air to water heat pump system

 

4PW53247-1B

 

Installation manual

 

3

 

I

 

NSTALLATION

 

 

 

OF

 

 

 

THE

 

 EKHTS 

 

DOMESTIC

 

 

 

HOT

 

 

 

WATER

 

 

 

TANK

 

If required by relevant local and national regulations, connect a
recirculation pump in between the hot water end point and the
recirculation connection of the domestic hot water tank.

 

Installation guidelines

 

Keep in mind the following guidelines when installing the domestic
hot water tank:

 

 

The installation location is frost-free.

 

 

Standard installation location of the domestic hot water tank is
on top of the indoor unit.

 

 

The domestic hot water tank can be floor mounted as well. In
that case, the dedicated EKFMAHTA connection kit for
installation of the domestic hot water tank next to the indoor unit
is required and to be ordered separately.

 

 

Locate the domestic hot water tank in a suitable position to
facilitate ease of maintenance. Refer to 

figure 3

  and to the

installation manual of the EKHBRD indoor unit.

 

 

Provide a connection for the pressure relief valve and drain on
the cold water inlet.

 

 

To  avoid back siphonage it is advised to install a non-return
valve on the cold water inlet of the domestic hot water tank in
accordance with local and national regulations.

 

 

Take  care that in the event of a leak, water can not cause any
damage to the installation space and surroundings.

 

 

It is advised to install a pressure reducing valve on the cold
water inlet in accordance with local and national regulations.

 

 

An expansion vessel should be installed on the cold water inlet
in accordance with local and national regulations.

 

Installing and commissioning the domestic hot water 

 

tank

Installing the hot water tank on top of the indoor unit

 

1

 

Unpack the domestic hot water tank according to the
instructions mentioned on the unpacking instruction sheet.

 

2

 

Check if all domestic hot water tank accessories are enclosed
(see 

"Accessories" on page 1

).

 

3

 

Remove front decoration panel and top plate of the indoor unit.

To  take away the front decoration panel, remove the 2 bottom
screws and then unhitch the panel.

Mount the top plate of the indoor unit on the domestic hot water
tank module.

 

4

Connect the 3-way valve

1

 

Remove drain plate on top of the
indoor unit before installing the
3-way valve.

 

2

 

Installation position.

The 3-way valve must be installed in the indoor unit.

 

 

Installation shall be done by a licensed technician, the
choice of materials and installation shall comply with
local and national regulations.

 

 

The equipment is not intended for use in a potentially
explosive atmosphere.

 

 

Domestic hot water quality must be according to EU
directive 98/83 EC.

 

 

A drain device should be installed on the cold water
connection on the domestic hot water tank.

 

 

For safety reasons, it is not allowed to add any kind of
glycol to the water circuit.

 

 

To  avoid stagnation of water, it is important that the
storage capacity of the domestic hot water tank meets
the daily consumption of domestic hot water.

In cases where during longer periods of time there is
no consumption of hot water, the equipment must be
flushed with fresh water before usage.

The disinfection function provided on the equipment is
specified in the operation manual of the indoor unit.

 

 

It is advised to avoid long runs of piping between the
domestic hot water tank and the hot water end point
(shower, bath, ...) and to avoid dead ends.

 

 

The installation must be in compliance with local and
national regulations and may require additional
hygienic installation measures.

 

 

In accordance with local and national regulations it
may be necessary to install thermostatic mixing
valves.

 

 

Immediately after installation, the domestic hot water
tank must be flushed with fresh water. This procedure
must be repeated at least once a day the first
5 consecutive days after installation.

 

If available service space to left and/or right side is
limited, carefully consider all indoor module
installation steps first.

3

4

1

2

1

Recirculation connection

2

Hot water connection

3

Shower

4

Recirculation pump

1

2

3

2x

1

1

1

2x

2x

2x

2x

4x

1

3

2

1

From indoor unit

2

To domestic hot water tank

3

To room heating

Summary of Contents for EKHTS200A

Page 1: ...INSTALLATION MANUAL EKHTS200A EKHTS260A EKHTSP200AA EKHTSP260AA EKHTSU200AA EKHTSU260AA EKUHWHTA Domestic hot water tank for air to water heat pump system ...

Page 2: ... 5x 1x 1x 1x 1 3 6 7 5 2 4 1x 340 mm 11 10 12 12 13 2 1 5 4 6 8 3 9 1 2 7 772 902 1032 H 120 Ø 6 0 1156 778 653 694 443 600 300 5 B C 250 250 A 600 30 D 30 2x 8 9 6 1 2 1 2 5 9 3 5 9 3 7 6 10 10 4 10 4 KHBRD 2 1 3 4 ...

Page 3: ... identification ACCESSORIES Accessories supplied with the domestic hot water tank See figure 1 Optional equipment EKFMAHTA Connection kit for installation of the domestic hot water tank on the floor next to the indoor unit Refer to the installation manual of the kit for more details EKHTS200A EKHTSP200AA EKHTS260A EKHTSP260AA Domestic hot water tank for air to water heat pump system Installation m...

Page 4: ...ve connection D Pressure relief valve field supply E Recirculation connection G 1 2 Male F Thermistor socket G Flow inlet connection from the main EKHBRD indoor unit at the bottom of the tank quick coupling H Heat exchanger coil J Return outlet connection to the main EKHBRD indoor unit at the bottom of the tank quick coupling K Cold water in connection G 3 4 Female L Thermistor A H K G J F E M Q P...

Page 5: ...op plate of the indoor unit To take away the front decoration panel remove the 2 bottom screws and then unhitch the panel Mount the top plate of the indoor unit on the domestic hot water tank module 4 Connect the 3 way valve 1 Remove drain plate on top of the indoor unit before installing the 3 way valve 2 Installation position The 3 way valve must be installed in the indoor unit Installation shal...

Page 6: ...s action so as to maintain the valve position as set during step 4 7 Put the turn knob on the valve motor cover as shown below Make sure that the turn knob is completely pushed in to allow the turn knob being operated automatically by the unit If the turn knob is lifted slightly manual operation is possible 8 Make sure to firmly fix the power supply cord onto the 3 way valve body with a field supp...

Page 7: ...oo see figure 4 7 Fix the side bottom decoration panels of the domestic hot water tank to the indoor unit 8 Connect the pressure relief valve field supply opening pressure maximum 10 bar and drain 9 Connect the thermistor wire to the indoor unit switch box Make sure power supply is switched off Refer to the wiring diagram delivered with the indoor unit The distance between the thermistor cable and...

Page 8: ...ng the hot water tank by the side of the indoor unit Refer to the manual delivered with the kit EKFMAHTA MAINTENANCE In order to ensure optimal availability of the unit a number of checks and inspections on the unit and the field wiring have to be carried out at regular intervals The described checks must be executed at least once a year by qualified personnel 1 Domestic hot water tank pressure re...

Page 9: ...devices may be bridged or changed to a value other than the factory setting If the cause of the problem cannot be found call your local dealer General symptoms Symptom 1 No water flow from hot taps Symptom 2 Water from hot taps is cold Symptom 3 Intermittent water discharge DISPOSAL REQUIREMENTS Dismantling of the unit and treatment of parts must be done in accordance with relevant local and natio...

Page 10: ...00 x 695 1610 x 600 x 695 Connections Quick coupling G 3 4 F Quick coupling G 3 4 F Quick coupling G 3 4 F Quick coupling G 3 4 F Inspection opening G1 2 M Recirculation connection G1 2 M Recirculation connection Ø125 mm Inspection and cleaning Ø125 mm Inspection and cleaning Weight empty 70 78 75 83 Mounting On top of EKHBRD or floor mounted On top of EKHBRD or floor mounted On top of EKHBRD or f...

Page 11: ...NOTES NOTES ...

Page 12: ...4PW53247 1B Copyright Daikin ...

Reviews: