background image

 

E260A + EK260AA

 

Domestic hot water tank for air to water heat pump system

 

4PW53247-1B

 

Installation manual

 

1

 

C

 

ONTENTS

 

Page

 

Introduction........................................................................................ 1

 

General information ................................................................................... 1
Scope of this manual ................................................................................. 1
Model identification .................................................................................... 1

 

Accessories ....................................................................................... 1

 

Accessories supplied with the domestic hot water tank............................. 1
Optional equipment.................................................................................... 1

Overview of the unit........................................................................................... 2

Main components....................................................................................... 2
Outlook diagram......................................................................................... 2

 

Installation of the EKHTS domestic hot water tank ........................... 3

 

Installation guidelines................................................................................. 3
Installing and commissioning the domestic hot water tank ........................ 3

 

Maintenance ...................................................................................... 6

 

Descaling ................................................................................................... 7
Draining...................................................................................................... 7

 

Troubleshooting ................................................................................. 7

 

General guidelines ..................................................................................... 7
General symptoms..................................................................................... 7

 

Disposal requirements....................................................................... 7

Technical specifications ..................................................................... 8

 

Domestic hot water tank specifications ...................................................... 8

 

The English text is the original instruction. Other languages are
translations of the original instructions.

 

I

 

NTRODUCTION

 

General information

 

Thank you for purchasing this domestic hot water tank.

The EKHTS domestic hot water tank can only be connected to the
EKHBRD indoor unit. The domestic hot water tank is available in two
sizes: approximately 200 and 260 litre. All models can be mounted
on top of the indoor unit. For installation of the domestic hot water
tank on the floor next to the indoor unit, the dedicated EKFMAHTA
connection kit is required.

 

Scope of this manual

 

This installation manual describes the procedures for unpacking,
installing and connecting the domestic hot water tank.

 

Model identification

 

A

 

CCESSORIES

 

Accessories supplied with the domestic hot water tank

 

See 

figure 1

 

Optional equipment

 

EKFMAHTA

Connection kit for installation of the domestic hot water tank on the
floor next to the indoor unit.

Refer to the installation manual of the kit for more details.

 

EKHTS200A

EKHTSP200AA

EKHTS260A

EKHTSP260AA

 

Domestic hot water tank 

for air to water heat pump system

 

Installation manual

 

READ THESE INSTRUCTIONS CAREFULLY BEFORE
INSTALLATION. KEEP THIS MANUAL IN A HANDY
PLACE FOR FUTURE REFERENCE.

IMPROPER INSTALLATION OR ATTACHMENT OF
EQUIPMENT OR ACCESSORIES COULD RESULT IN
ELECTRIC SHOCK, SHORT-CIRCUIT, LEAKS, FIRE OR
OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY
TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE
SPECIFICALLY DESIGNED FOR USE WITH THE
EQUIPMENT AND HAVE THEM INSTALLED BY A
PROFESSIONAL.

IF UNSURE OF INSTALLATION PROCEDURES OR USE,
ALWAYS CONTACT YOUR DAIKIN DEALER FOR
ADVICE AND INFORMATION.

THE UNIT DESCRIBED IN THIS MANUAL IS DESIGNED
FOR INDOOR INSTALLATION ONLY AND FOR AMBIENT
TEMPERATURES RANGING 5°C~35°C.

 

NOTE

 

Especially for the United Kingdom

 

For installation of an EKHTSU domestic hot water
tank, refer to the part of EKHTSU in this manual.

 

EK

HTS

P

200

A

 

Series

Identification of type

P = Special version with service opening (125 mm)
Standard version when no letter is mentioned

Hot water Tank Stainless steel

European Kit

 

1

 

Flexible hose of heat exchanger coil

 

2

 

Hot/cold water flexible hose

 

3

 

Clamp

 

4

 

Installation manual

 

5

 

Unpacking instruction sheet

 

6

 

3-way valve assembly (body + motor + pipe + screws)

 

7

 

Knockout hole assembly (g screws)

Summary of Contents for EKHTS200A

Page 1: ...INSTALLATION MANUAL EKHTS200A EKHTS260A EKHTSP200AA EKHTSP260AA EKHTSU200AA EKHTSU260AA EKUHWHTA Domestic hot water tank for air to water heat pump system ...

Page 2: ... 5x 1x 1x 1x 1 3 6 7 5 2 4 1x 340 mm 11 10 12 12 13 2 1 5 4 6 8 3 9 1 2 7 772 902 1032 H 120 Ø 6 0 1156 778 653 694 443 600 300 5 B C 250 250 A 600 30 D 30 2x 8 9 6 1 2 1 2 5 9 3 5 9 3 7 6 10 10 4 10 4 KHBRD 2 1 3 4 ...

Page 3: ... identification ACCESSORIES Accessories supplied with the domestic hot water tank See figure 1 Optional equipment EKFMAHTA Connection kit for installation of the domestic hot water tank on the floor next to the indoor unit Refer to the installation manual of the kit for more details EKHTS200A EKHTSP200AA EKHTS260A EKHTSP260AA Domestic hot water tank for air to water heat pump system Installation m...

Page 4: ...ve connection D Pressure relief valve field supply E Recirculation connection G 1 2 Male F Thermistor socket G Flow inlet connection from the main EKHBRD indoor unit at the bottom of the tank quick coupling H Heat exchanger coil J Return outlet connection to the main EKHBRD indoor unit at the bottom of the tank quick coupling K Cold water in connection G 3 4 Female L Thermistor A H K G J F E M Q P...

Page 5: ...op plate of the indoor unit To take away the front decoration panel remove the 2 bottom screws and then unhitch the panel Mount the top plate of the indoor unit on the domestic hot water tank module 4 Connect the 3 way valve 1 Remove drain plate on top of the indoor unit before installing the 3 way valve 2 Installation position The 3 way valve must be installed in the indoor unit Installation shal...

Page 6: ...s action so as to maintain the valve position as set during step 4 7 Put the turn knob on the valve motor cover as shown below Make sure that the turn knob is completely pushed in to allow the turn knob being operated automatically by the unit If the turn knob is lifted slightly manual operation is possible 8 Make sure to firmly fix the power supply cord onto the 3 way valve body with a field supp...

Page 7: ...oo see figure 4 7 Fix the side bottom decoration panels of the domestic hot water tank to the indoor unit 8 Connect the pressure relief valve field supply opening pressure maximum 10 bar and drain 9 Connect the thermistor wire to the indoor unit switch box Make sure power supply is switched off Refer to the wiring diagram delivered with the indoor unit The distance between the thermistor cable and...

Page 8: ...ng the hot water tank by the side of the indoor unit Refer to the manual delivered with the kit EKFMAHTA MAINTENANCE In order to ensure optimal availability of the unit a number of checks and inspections on the unit and the field wiring have to be carried out at regular intervals The described checks must be executed at least once a year by qualified personnel 1 Domestic hot water tank pressure re...

Page 9: ...devices may be bridged or changed to a value other than the factory setting If the cause of the problem cannot be found call your local dealer General symptoms Symptom 1 No water flow from hot taps Symptom 2 Water from hot taps is cold Symptom 3 Intermittent water discharge DISPOSAL REQUIREMENTS Dismantling of the unit and treatment of parts must be done in accordance with relevant local and natio...

Page 10: ...00 x 695 1610 x 600 x 695 Connections Quick coupling G 3 4 F Quick coupling G 3 4 F Quick coupling G 3 4 F Quick coupling G 3 4 F Inspection opening G1 2 M Recirculation connection G1 2 M Recirculation connection Ø125 mm Inspection and cleaning Ø125 mm Inspection and cleaning Weight empty 70 78 75 83 Mounting On top of EKHBRD or floor mounted On top of EKHBRD or floor mounted On top of EKHBRD or f...

Page 11: ...NOTES NOTES ...

Page 12: ...4PW53247 1B Copyright Daikin ...

Reviews: