EKHVWQ0 E260AA1V3

Domestic hot water heat pump

4PW65343-1A – 10.2010

Operation manual

4

5.

O

PERATING

 

THE

 

UNIT

5.1.

Introduction

The heat pump system is designed to provide you domestic hot water
for many years at low energy consumption.

To get the most comfort with the lowest running cost of your system, it
is very important to observe the items listed below.

Defining possible schedule timer actions for each day and filling out
the form at the very end of this manual can help you minimize the
energy consumption. Ask your installer for support if required.

Make sure the heat pump system works at the lowest possible
hot water temperature required to fulfill your domestic hot water
needs.

To optimize this, make sure the auto adaptive set point is used.
Refer to "Auto adaptive set point operation" on page 9.

Recommendation 

If you set the set point manually, make sure the domestic hot
water is only heated up to the domestic hot water
temperature you require.
Start with a low domestic hot water temperature set point
(e.g. 45°C), and only increase if you feel that the domestic
hot water supply temperature is not sufficient.

Also keep hours with low electricity cost tariffs in mind.
To do this, program the domestic water heating schedule
timer. Refer to "Programming" in chapter "Programming and
consulting the schedule timer" on page 9.

5.2.

Operating the digital controller

Operating the domestic hot water heat pump comes down to
operating the digital controller.

Features and functions

The digital controller is a state of the art controller that offers full
control over your installation.

Basic controller functions

The basic controller functions are:

Turning the unit ON/OFF.

Schedule timer/continuous mode

Selection of features:
-

quiet mode (refer to page 8),

-

auto adaptive set point control (refer to page 9).

Temperature set point adjustment (refer to page 6).

Powerful mode

The digital controller supports a power cut off of maximum 2 hours.
When autorestart is enabled (see 

"Field settings" in the installation

manual

) this allows a power supply shut down of 2 hours without user

intervention (e.g. benefit kWh rate power supply).

Clock function

The clock functions are:

24 hour real time clock.

Day of the week indicator.

Schedule timer function

The schedule timer function allows the user to schedule the operation
of the installation according to a daily or a weekly program.

INFORMATION

Use the auto adaptive set point to optimise.

INFORMATION

There is a default schedule timer set (refer to
"Schedule timer operation" on page 7).

CAUTION

Never let the digital controller get wet. This may cause
an electric shock or fire.

Never press the buttons of the digital controller with a
hard, pointed object. This may damage the digital
controller.

Never inspect or service the digital controller yourself,
ask a qualified service person to do this.

Do not rinse the indoor unit. This may cause electric
shock or fire.

Do not climb, sit or stand on top of the unit.

Do not place any objects or equipment on the unit top
plate.

NOTICE

Descriptions in this manual that apply to a specific
installation or that depend on the installed equipment,
are marked with an asterisk (*).

Some functions described in this manual may not be
available or should not be available. Ask your installer
or your local dealer for more information on
permission levels.

Summary of Contents for EKHHS200AA1V3

Page 1: ...OPERATION MANUAL EKHVWQ002AAV3 EKHHS200AA1V3 EKHHS260AA1V3 Domestic hot water heat pump ...

Page 2: ...ance activities 16 7 3 Standstill 16 8 Troubleshooting 17 9 Disposal requirements 17 The English text is the original instruction Other languages are translations of the original instructions This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruc...

Page 3: ...s a potentially hazardous situation which if not avoided may result in minor or moderate injury It may also be used to alert against unsafe practices NOTICE Indicates situations that may result in equipment or property damage accidents only INFORMATION This symbol identifies useful tips or additional information Electric current Danger of burning and scalding DANGER ELECTRICAL SHOCK Switch off all ...

Page 4: ...nual 4 1 Domestic water heating operation quick start up Schedule timer operation Continuous operation Powerful operation INFORMATION Refer to the installation manual of the unit for installation procedures Icon p is displayed a a To display or remove the p icon press the pr button Schedule timer operation Push the ba button Push the Y button Push the Y button The 0 LED will light up and the unit ...

Page 5: ...fers full control over your installation Basic controller functions The basic controller functions are Turning the unit ON OFF Schedule timer continuous mode Selection of features quiet mode refer to page 8 auto adaptive set point control refer to page 9 Temperature set point adjustment refer to page 6 Powerful mode The digital controller supports a power cut off of maximum 2 hours When autorestar...

Page 6: ...ailable 14 DEFROST MODE ICON d This icon indicates that the defrost mode is active 15 COMPRESSOR ICON ç This icon indicates that the compressor of the heat pump unit is active When freeze protection mode is active this icon is blinking 16 BOOSTER HEATER ICON m This icon indicates that the booster heater is active The booster heater provides auxiliary heating for the domestic hot water tank if a hi...

Page 7: ...e by 10 minutes 3 Use the wi or wj button to adjust the day of the week Each time the wi or wj button is pressed the next or previous day is displayed 4 Press the button to confirm the current set time and day of the week To leave this procedure without saving press the pr button If no button is pressed for 5 minutes the clock and day of the week will return to their previous setting Setting the sc...

Page 8: ... command It is clear that the last programmed command may date from the day before Refer to Consulting programmed actions on page 12 INFORMATION Default the schedule timer is set as follows Time Set point temperature Sunday until thursday 7 4 22 6 h 45 C Friday and saturday 5 6 22 6 h 55 C If this does not fullfill the customers demands it has to be set as explained in Programming and consulting th...

Page 9: ...he desired quiet mode is set through a field setting Refer to the field settings explained in the installation manual for a detailed description how to set one or more field settings Disinfection operation This mode will disinfect the domestic hot water tank by periodically heating the domestic water to a specific temperature During the operation of this mode the w icon will be blinking slowly with 0 ...

Page 10: ...more actions are programmed for the same day and at the same time only the action with the lowest action number will be executed You can always alter add or remove the programmed actions later Example 1 Example 2 If on mondays the customer is usually at home and uses a lot of hot water the set point for monday will increase untill the required amount of hot water is reached as shown in the figure b...

Page 11: ...s e g 4 and 5 are not displayed 7 Press the button for 5 seconds to enter the programming mode 8 Use the button to select the action number you would like to program or to modify 9 Use the pi and pj buttons to set the correct action time 10 Use the ba button to select x to switch heating and the controller off 9 set the temperature by means of the wi and wj buttons 11 Repeat steps 8 to 10 to progr...

Page 12: ...rogramming mode 6 Use the button to select the action number you would like to program or to modify 7 Use the pi and pj buttons to set the correct action time 8 Use the ba button to select or deselect x as action 9 Repeat steps 6 to 8 to program the other actions of the selected mode When all actions have been programmed make sure that the display shows the highest action number you would like to ...

Page 13: ...i e after pressing the button for 5 seconds press the pr button once You can now select another day by using the pi and pj buttons and restart consulting and programming Copying programmed actions to next day In heating mode program it is possible to copy all programmed actions of a specific day to the next day e g copy all programmed actions from 1 to 2 To copy programmed actions to the next day p...

Page 14: ...on If the P button is pressed the heat pump module heats up the domestic hot water tank as fast as possible to a predefined setpoint This means that the inverter compressor frequency will be higher then in normal operation mode and that sound level and power consumption can be higher This mode might be usefull when exceptional high hot water consumption depletes all the available domestic hot water...

Page 15: ...ed defines whether the reheat operation is turned ON 1 or OFF 0 1 Automatic domestic hot water tank temperature set point calculation 1 00 Renewal time for set point calculation The automatic temperature set point calculation is done on a daily basis The algorithm calculates for each day of the week an optimum domestic hot water tank temperature set point To calculate this temperature setpoint the ...

Page 16: ...lated setting 1 ON 02 Installation related setting 23 00 03 Installation related setting 0 OFF 04 Installation related setting 32 3 Miscellaneous 00 Installation related setting 1 ON 01 Installation related setting 3 02 Installation related setting 0 OFF 03 Installation related setting 0 OFF 4 Miscellaneous 03 Installation related setting 0 04 Installation related setting 1 6 Miscellaneous 00 Inst...

Page 17: ...dissipate this gas safely it is recommended that a hot tap be turned on for several minutes at a sink basin or bath but not at a dishwasher clothes washer or other appliance During this procedure there must be no smoking open flame or any electrical appliance operating nearby If hydrogen is discharged through the tap it will probably make a sound as of air escaping Each inspection has to be carried...

Page 18: ...zed treatment facility for re use recycling and recovery By ensuring this product is disposed off correctly you will help to prevent potential negative consequences for the environment and human health Please contact the installer or local authority for more information NOTES POSSIBLE CAUSES CORRECTIVE ACTIONS No readings on the remote controller blank display Check if the mains power is still con...

Page 19: ......

Page 20: ...4PW65343 1A 10 2010 Copyright 2010 Daikin ...

Reviews: