background image

EKHVWQ0 E260AA1V3

Domestic hot water heat pump

4PW65343-1A – 10.2010

Operation manual

6

27.

SCHEDULE TIMER BUTTON 

r

/

p

The main function of this multi-purpose button is to
enable/disable the schedule timer. If the schedule timer is
disabled, the system will heat up the domestic water the whole
day as long as the actual domestic hot water tank temperature is
lower than the set point temperature.

The button is also used to program the controller. The function of
the button depends on the actual status of the controller or on
previous actions carried out by the operator.

If the controller is set in permission level 3 (refer to "Field
settings" on page 13), the schedule timer b
utton will not be
operable.

28.

TIME ADJUST BUTTON 

pi

 and 

pj

These multi-purpose buttons are used to adjust the clock and in
schedule timer programming mode.

29.

DOMESTIC HOT WATER TEMPERATURE ADJUST BUTTONS

wbi

 and 

wbj

These multi-purpose buttons are used to adjust the current set
point of the domestic hot water in continuous operation mode or
in schedule timer programming mode. The buttons are also used
to select the weekday while setting the clock.

30.

POWERFUL MODE BUTTON 

P

This button is used if a sudden request for hot water is needed
while no hot water is available in the domestic hot water tank.
When pushed, the domestic water will be heated up fast until the
set point temperature (determined by field setting) is reached.
The 

w

 icon wil be blinking rapidly with 0.2 seconds interval.

This action is only possible when the unit is operating. If the
powerful mode button (

P

) is pressed when the unit is in OFF

mode, the "

n

" message will be displayed.

31.

QUIET MODE BUTTON 

s

This button enables or disables quiet mode.

If the controller is set in permission level 3 (refer to "Field
settings" on page 13), the quiet mode b
utton will not be
operable.

5.3.

Setting up the controller

After initial installation, the user can set the clock and day of the
week.

The controller is equipped with a schedule timer that enables the user
to schedule operations. Setting the clock and day of the week is
required to be able to use the schedule timer.

Setting the clock

1

Hold down the 

pr

 button for 5 seconds.

The clock read-out and the day of week indicator start flashing.

2

Use the 

pi

 and 

pj

 buttons to adjust the clock.

Each time the 

pi

 or 

pj

 button is pressed, the time will

increase/decrease by 1 minute. Keeping the 

pi

 or 

pj

button pressed will increase/decrease the time by 10 minutes.

3

Use the 

wi

 or 

wj

 button to adjust the day of the week.

Each time the 

wi

 or 

wj

 button is pressed the next or

previous day is displayed.

4

Press the 

<

 button to confirm the current set time and day of the

week.

To leave this procedure without saving, press the 

pr

 button.

If no button is pressed for 5 minutes the clock and day of the
week will return to their previous setting.

Setting the schedule timer

To set the schedule timer, refer to chapter "Programming and
consulting the schedule timer" on page 9.

5.4.

Description of the operation modes

Basic domestic water heating operation (

w

)

In this mode, the indoor unit will heat up the domestic hot water tank.

There are 2 basic domestic water heating modes: continuous mode
and scheduled timer mode. All heating will be activated as required
by the water temperature set point. The set point can be set manually
or auto adaptive (refer to "Auto adaptive set point operation" on
page 9).

Continuous operation

In continuous operation mode, the domestic water is always heated
up to the required set point. As soon as the domestic water
temperature is lower than the set point temperature (taking into
account the heat pump ON differential), the heating up of the
domestic water will start automatically. This operation mode remains
enabled until the schedule timer button is pressed (refer to "Schedule
timer operation" on page 7).

As the controller has a wide variety of functions, it is possible to
select a function which is restricted at a certain moment. In that case
the message 

n

 will appear.

Switching on domestic water heating (

w

)

1

Switch on the unit by pushing the 

Y

 button.

The operation LED 

0

 lights up.

2

For continuous operation the 

p

 icon must be OFF.

3

Use the 

wi

 and 

wj

 buttons to set the desired water

temperature.

The temperature range for heating is by default 35°C to 60°C.
This means that in default operation only the heat pump will heat
up the water.

For temperatures higher than 60°C (until 75°C maximum) refer
to the field settings explained in the installation manual.

In order to avoid freezing of installation space, heating by the
heat pump is not operable when the indoor ambient temperature
drops below a certain temperature (refer to the field settings
explained in the installation manual). The booster heater will
take over the heating proces.

The clock needs to be set manually. Adjust the setting
when switching from summertime to wintertime and vice
versa.

INFORMATION

The domestic hot water temperature set point can also be
auto adaptive (icon 

a

 is shown).

This means that the controller calculates the water
temperature set point based on the history of use of
domestic hot water.

Summary of Contents for EKHHS200AA1V3

Page 1: ...OPERATION MANUAL EKHVWQ002AAV3 EKHHS200AA1V3 EKHHS260AA1V3 Domestic hot water heat pump ...

Page 2: ...ance activities 16 7 3 Standstill 16 8 Troubleshooting 17 9 Disposal requirements 17 The English text is the original instruction Other languages are translations of the original instructions This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruc...

Page 3: ...s a potentially hazardous situation which if not avoided may result in minor or moderate injury It may also be used to alert against unsafe practices NOTICE Indicates situations that may result in equipment or property damage accidents only INFORMATION This symbol identifies useful tips or additional information Electric current Danger of burning and scalding DANGER ELECTRICAL SHOCK Switch off all ...

Page 4: ...nual 4 1 Domestic water heating operation quick start up Schedule timer operation Continuous operation Powerful operation INFORMATION Refer to the installation manual of the unit for installation procedures Icon p is displayed a a To display or remove the p icon press the pr button Schedule timer operation Push the ba button Push the Y button Push the Y button The 0 LED will light up and the unit ...

Page 5: ...fers full control over your installation Basic controller functions The basic controller functions are Turning the unit ON OFF Schedule timer continuous mode Selection of features quiet mode refer to page 8 auto adaptive set point control refer to page 9 Temperature set point adjustment refer to page 6 Powerful mode The digital controller supports a power cut off of maximum 2 hours When autorestar...

Page 6: ...ailable 14 DEFROST MODE ICON d This icon indicates that the defrost mode is active 15 COMPRESSOR ICON ç This icon indicates that the compressor of the heat pump unit is active When freeze protection mode is active this icon is blinking 16 BOOSTER HEATER ICON m This icon indicates that the booster heater is active The booster heater provides auxiliary heating for the domestic hot water tank if a hi...

Page 7: ...e by 10 minutes 3 Use the wi or wj button to adjust the day of the week Each time the wi or wj button is pressed the next or previous day is displayed 4 Press the button to confirm the current set time and day of the week To leave this procedure without saving press the pr button If no button is pressed for 5 minutes the clock and day of the week will return to their previous setting Setting the sc...

Page 8: ... command It is clear that the last programmed command may date from the day before Refer to Consulting programmed actions on page 12 INFORMATION Default the schedule timer is set as follows Time Set point temperature Sunday until thursday 7 4 22 6 h 45 C Friday and saturday 5 6 22 6 h 55 C If this does not fullfill the customers demands it has to be set as explained in Programming and consulting th...

Page 9: ...he desired quiet mode is set through a field setting Refer to the field settings explained in the installation manual for a detailed description how to set one or more field settings Disinfection operation This mode will disinfect the domestic hot water tank by periodically heating the domestic water to a specific temperature During the operation of this mode the w icon will be blinking slowly with 0 ...

Page 10: ...more actions are programmed for the same day and at the same time only the action with the lowest action number will be executed You can always alter add or remove the programmed actions later Example 1 Example 2 If on mondays the customer is usually at home and uses a lot of hot water the set point for monday will increase untill the required amount of hot water is reached as shown in the figure b...

Page 11: ...s e g 4 and 5 are not displayed 7 Press the button for 5 seconds to enter the programming mode 8 Use the button to select the action number you would like to program or to modify 9 Use the pi and pj buttons to set the correct action time 10 Use the ba button to select x to switch heating and the controller off 9 set the temperature by means of the wi and wj buttons 11 Repeat steps 8 to 10 to progr...

Page 12: ...rogramming mode 6 Use the button to select the action number you would like to program or to modify 7 Use the pi and pj buttons to set the correct action time 8 Use the ba button to select or deselect x as action 9 Repeat steps 6 to 8 to program the other actions of the selected mode When all actions have been programmed make sure that the display shows the highest action number you would like to ...

Page 13: ...i e after pressing the button for 5 seconds press the pr button once You can now select another day by using the pi and pj buttons and restart consulting and programming Copying programmed actions to next day In heating mode program it is possible to copy all programmed actions of a specific day to the next day e g copy all programmed actions from 1 to 2 To copy programmed actions to the next day p...

Page 14: ...on If the P button is pressed the heat pump module heats up the domestic hot water tank as fast as possible to a predefined setpoint This means that the inverter compressor frequency will be higher then in normal operation mode and that sound level and power consumption can be higher This mode might be usefull when exceptional high hot water consumption depletes all the available domestic hot water...

Page 15: ...ed defines whether the reheat operation is turned ON 1 or OFF 0 1 Automatic domestic hot water tank temperature set point calculation 1 00 Renewal time for set point calculation The automatic temperature set point calculation is done on a daily basis The algorithm calculates for each day of the week an optimum domestic hot water tank temperature set point To calculate this temperature setpoint the ...

Page 16: ...lated setting 1 ON 02 Installation related setting 23 00 03 Installation related setting 0 OFF 04 Installation related setting 32 3 Miscellaneous 00 Installation related setting 1 ON 01 Installation related setting 3 02 Installation related setting 0 OFF 03 Installation related setting 0 OFF 4 Miscellaneous 03 Installation related setting 0 04 Installation related setting 1 6 Miscellaneous 00 Inst...

Page 17: ...dissipate this gas safely it is recommended that a hot tap be turned on for several minutes at a sink basin or bath but not at a dishwasher clothes washer or other appliance During this procedure there must be no smoking open flame or any electrical appliance operating nearby If hydrogen is discharged through the tap it will probably make a sound as of air escaping Each inspection has to be carried...

Page 18: ...zed treatment facility for re use recycling and recovery By ensuring this product is disposed off correctly you will help to prevent potential negative consequences for the environment and human health Please contact the installer or local authority for more information NOTES POSSIBLE CAUSES CORRECTIVE ACTIONS No readings on the remote controller blank display Check if the mains power is still con...