Product description
Item
Name (EKHHP)
Item
Name (Controller)
1
Flow Solar or flow for additional heat source (1" female thread)
30
Key "On / Off"
2
Cold water connection (1“ male thread)
31
Operating Display LED
3
Hot water (1“ male thread)*
32
Display operating mode "Low Noise Mode" active
4
Flow
Solar or for additional heat source (3/4" female 1“ male thread) (only
EKHHP500AA2V3)
33
Display operating mode "Hot Water Heating" active
5
Return
Solar for additional heat source (3/4" female 1“ male thread) (only
EKHHP500AA2V3)
34
Display of sensor number (see Tab. 7.1)
6
Connection refrigerant gas line
Cu Ø 3/8" (9.5 mm)
35
Display time
7
Connection refrigerant liquid line
Cu Ø 1/4" (6.4 mm)
36
Display weekday
7a
Recommended accessory:non-return valves(2 pcs.)
37
Display refrigerant compressor active
9
Storage tank ( polypropylene double walled jacket with PUR hard foam heat insulation)
38
Display switching timer programme switc
hed on
10
Filling and draining connection or return
Solar or return for additional heat source
39
Display active switching times
11
Mount for solar controller or handle
40
Display off status in timer programme
12
Heat exchanger (stainless steel) for domestic hot water heating
41
Display Booster-Heater (BSH) switched on
13
Heat exchanger (stainless steel) for storage tank charging by hot water heat pump (liquifier)
42
Display external signal (HT/NT
/ Smart Grid)
14
Heat exchanger (stainless steel) for storage tank charging by pressurised solar or alternative heat gener-
ator
(only EKHHP500AA2V3)
43
Display operating mode "Start-up", "Defrost Mode" active
15
Connection for integrated electrical Booster-Heater BSH (R 1½" female thread)
44
Display external temperature or temperature i
n hot water storage tank
17
Fill level indicator (tank water)
45
Display operating mode "Automatic" active
18
Integrated electrical Booster-Heater (BSH)
46
Display external temperature active
19
Sensor pocket for tank temperature sensor t
DHW
47
Display of hot water temperature or oher temperature values (in combination with Items 44 / 46)
20
Pressure-free storage tank water
48
Display "Function not available"
23
Connection safety overflow
49
Display parameter setting mode active
24
Mount for handle
50
Display service technician required
25
Silencer hood
51
Display Parameter code or Fault code
26
Type plate
52
Keys setting hot water temperature
27
Regulator hot water heat pump
53
Key "Automatic" operating mode
54
Key programming
outer
thread
outer thread
55
Key "High Output" operating mode
inter-
nal
thread
internal thread
56
Key activation/deactivation of timer programme
t
DHW
Storage tank temperature sensor
57
Key "Low Noise" operating mode
Safety devices
58
Keys Time setting
Observe tightening torque!
59
Key error code / parameter setting
Brief push: Display last error code
Push for 5
sec: Enter parameter settings