Installation and operating instructions
16
DAIKIN EKHHP(3/5)00AA2V3
DAIKIN Hot water heat pump
008.1423444_05 – 08/2016
4
x
Set-up and installation
4.8.3 Connection EVU receiver (intelligent regulator
Smart Grid - SG)
Once the function is activated by the parameter [7-00] = 3 (see
Section 7.5.2), the heat pump is changed to Stand-By, Normal or
an operating mode with higher temperatures, depending on the
signal from the energy supply company.
To do this, the
potential-free switchinf contacts
HT/NT + SG
of
the EVU receiver need to be connected to the
terminal rail con-
nections (GND+IN1) / (GND+IN2)
of the DAIKIN EKHHP (see
Fig. 4-12).
As soon as the function Smart Grid is active, the HT/NT function
is deactivated automatically. Depending on the value of the pa-
rameter [7-00], the heat pump is operated differently (see
Tab. 7-3).
4.8.4 Optional: Connection of an external heat
generator
When using an external heat generator, this can be connected
using a potential-free switching contact (HT/NT) on the DAIKIN
EKHHP.
If the potential-free switching contact is closed by an external
heat generator, the DAIKIN EKHHP reduces its own heat gener-
ation in order to favour the external heat generator (settings see
Section 7.5.2).
HT/NT
High/low tariff mains connection (EVU receiver)
SG
Smart Grid connection (EVU receiver)
GND+IN1 connection HT/NT switching contact on EKHHP
GND+IN2 connection Smart Grid switching contact on EKHHP
X2M Terminal rail on EKHHP
Fig. 4-12 Electrical connection HT/NT - and Smart Grid switching con-
tact
GND + IN1 connection potential-free switching contact on EKHHP
WEX External heat generator
X2M Terminal rail on EKHHP
Fig. 4-13 External heat generator electrical connection