EKHBH/XE008BA

Indoor unit for air to water heat pump system and options

4PW56302-1

Operation manual

18

M

AINTENANCE

Important information regarding the refrigerant used

This product contains fluorinated greenhouse gases covered by the
Kyoto Protocol.

Refrigerant type:

R410A

GWP

(1)

 value:

1975

(1)

 GWP = global warming potential

Periodical inspections for refrigerant leaks may be required
depending on European or local legislation. Please contact your local
dealer for more information.

Maintenance activities

In order to ensure optimal availability of the unit, a number of checks
and inspections on the unit and the field wiring have to be carried out
at regular intervals, preferably yearly. This maintenance should be
carried out by your local Daikin technician (see installation manual).

The only maintenance which may be required by the operator is:

keeping the remote controller clean by means of a soft damp
cloth,

checking if the water pressure indicated on the manometer is
above 1 bar.

Only for the optional domestic hot water tank:

A check for correct operation of the pressure relief valve
installed on your domestic hot water tank, has to be carried out
at least every 6 months: it is important that the lever on the valve
is actuated to prevent accumulation of mineral deposits that may
impair valve operation and to confirm that the valve and
discharge pipe are not blocked. The lever should be operated
slowly and smoothly to avoid a sudden rush of hot water from
the discharge pipe.
Failure to operate the relief valve actuating lever may result in
the water heater exploding.

Continuous leakage of water from the discharge pipe may
indicate a problem with the water heater.

If a discharge pipe is connected to the pressure relief device it
must be installed in a continuously downward direction and in a
frost-free environment. It must be left open to the atmosphere.

Standstill

T

ROUBLESHOOTING

The guidelines below might help to solve your problem. If you cannot
solve the problem, consult your installer.

D

ISPOSAL

 

REQUIREMENTS

Dismantling of the unit, treatment of the refrigerant, of oil and of other
parts must be done in accordance with relevant local and national
legislation.

Your product is marked with this symbol. This means that
electrical and electronic products shall not be mixed with
unsorted household waste.

Do not try to dismantle the system yourself: the dismantling of the
system, treatment of the refrigerant, of oil and other parts must be
done by a qualified installer in accordance with relevant local and
national legislation.

Units must be treated at a specialized treatment facility for re-use,
recycling and recovery. By ensuring this product is disposed off
correctly, you will help to prevent potential negative consequences for
the environment and human health. Please contact the installer or
local authority for more information.

DANGER

Do not touch water pipes during and immediately after
operation as the pipes may be hot. Your hand may
suffer burns. To avoid injury, give the piping time to
return to normal temperature or be sure to wear
proper gloves.

Do not touch any switch with wet fingers. Touching a
switch with wet fingers can cause electrical shock.

WARNING

Do not touch the refrigerant pipes during and immediately
after operation as the refrigerant pipes may be hot or cold,
depending on the condition of the refrigerant flowing
through the refrigerant piping, compressor, and other
refrigerant cycle parts. Your hands may suffer burns or
frostbite if you touch the refrigerant pipes. To avoid injury,
give the pipes time to return to normal temperature or, if
you must touch them, be sure to wear proper gloves.

CAUTION

If the supply cord is damaged, it must be replaced by the
manufacturer, its agent or similar qualified persons in order
to avoid hazards.

NOTE

During longer periods of standstill, e.g. during
summer with a heating only application, it is very
important NOT TO SWITCH OFF THE POWER
SUPPLY towards the unit.

Switching off the power supply stops the
automatic repetitive movement of the pump in
order to prevent it from getting jammed.

When the unit is turned off for some days during
winter, then this should be considered as a start-
up at low ambient temperature. Refer to the
chapter "Start-up at low outdoor ambient
temperatures" in the installation manual to ensure
that the unit operates within its operation range as
soon as possible.

P

OSSIBLE

 

CAUSES

C

ORRECTIVE

 

ACTIONS

No readings on the remote controller 
(blank display)

Check if the mains power is still 
connected to your installation.

One of the error codes appears

Consult your local dealer.
Refer to the installation manual for a 
detailed list of error codes.

The schedule timer does work but 
the programmed actions are 
executed at the wrong time
(e.g. 1 hour too late or too early)

Check if the clock and the day of the 
week are set correctly, correct if 
necessary.

The schedule timer is programmed 
but does not work.

In case the 

pr

 icon is not displayed, 

push the 

pr

 button to enable the 

schedule timer.

Capacity shortage

Consult your local dealer.

Summary of Contents for EKHBHE008BA3V3

Page 1: ...OPERATION MANUAL EKHBHE008BA3V3 EKHBXE008BA3V3 Indoor unit for air to water heat pump system and options For installation WITH restricted power supply condition 6 kW ...

Page 2: ...timer by means of the controller maintain the unit and solve operational problems General information Thank you for purchasing this indoor unit The unit is the indoor part of the air to water ERHQ or ERLQ heat pumps These units are designed for wall mounted indoor installation The units can be combined with Daikin fan coil units floor heating applications low temperature radiators Daikin domestic ...

Page 3: ...and will stop the outdoor unit and the indoor circulation pump when the room temperature is above the thermostat set point Next recommendations only apply to installations with an optional domestic hot water tank Make sure the domestic hot water is only heated up to the domestic hot water temperature you require Start with a low domestic hot water temperature set point e g 45 C and only increase i...

Page 4: ... unit If during backup heater operation the heating load is higher than the heater capacity the water temperature can not increase In this case refer to Re start at low outdoor ambient temperatures in the installation manual Balance between space heating cooling demand and domestic hot water demand Only if the unit is correctly sized then at some point during space cooling heating operation the un...

Page 5: ...rogramming the schedule timer 10 INSPECTION REQUIRED k and l These icons indicate that inspection is required on the installation Consult your dealer 11 SET TEMPERATURE DISPLAY 9 The display shows the current space heating cooling set temperature of the installation 12 SETTING Not used For installation purposes only 13 NOT AVAILABLE n This icon is displayed whenever a non installed option is addre...

Page 6: ...roller is set in permission level 2 or 3 refer to Field settings on page 13 the quiet mode button will not be operable Setting up the controller After initial installation the user can set the clock and day of the week The controller is equipped with a schedule timer that enables the user to schedule operations Setting the clock and day of the week is required to be able to use the schedule timer ...

Page 7: ...oid overheating space heating is not operable when the outdoor ambient temperature rises above a certain temperature as set through field setting 4 02 refer to Field settings on page 13 Temperature range for cooling 5 C to 22 C 3 Switch on the unit by pushing the y button The operation LED 0 lights up The space cooling temperature set point can only be set manually refer to Manual operation on pag...

Page 8: ...r disabled p icon not displayed by pressing the pr button To set up the SCHEDULE TIMER refer to chapter Programming and consulting the schedule timer on page 8 What can the schedule timer do The schedule timer allows the programming of 1 Space heating and space cooling refer to Programming space heating or space cooling on page 9 Switch on the desired mode at a scheduled time in combination with a...

Page 9: ...with the highest action number will be executed You can always alter add or remove the programmed actions later When programming heating actions time and set point cooling actions are added automatically at the same time but with the predefined default cooling set point Conversely when programming cooling actions time and set point heating actions are added automatically at the same time but with ...

Page 10: ...n to select x to switch cooling or heating and the controller off 9 set the temperature by means of the bi and bj buttons a to select automatic temperature calculation only in heating mode 10 Use the pi and pj buttons to set the correct action time 11 Repeat steps 8 to 10 to program the other actions of the selected day When all actions have been programmed make sure that the display shows the hig...

Page 11: ...s Consulting space heating or space cooling is carried out as follows 1 Use the button to select the operation mode cooling or heating you want to consult 2 Press the button The actual mode is blinking 3 Press the button to confirm the selected mode The actual day is blinking 4 Select the day you would like to consult by means of the pi and pj buttons The selected day is blinking 5 Press the butto...

Page 12: ... 3 are stored but 4 and 5 are deleted Deleting a mode 1 Press the button The actual mode is blinking 2 Use the pi and pj buttons to select the mode you want to delete quiet mode s booster heating m or domestic water heating w The selected mode is blinking 3 Press the and ba button simultaneously for 5 seconds to delete the selected mode Deleting a day of the week cooling or heating mode 1 Use the ...

Page 13: ...ton to select action number 2 11 Use the pi and pj buttons to set the action time to 4 00 12 Use the ba buttons to select what the unit should do from 4 00 onwards 9 set the tempearature by means of the bi and bj buttons a to select automatic temperature calculation only in heating mode 13 Press the button for 5 seconds to store the programmed actions You automatically return to step 4 By pressing...

Page 14: ...d domestic hot water schedule timers are used make sure they are enabled during the period that space heating cooling is disabled Example pattern 0 0 0 0 0 0 0 00 0 0 0 1 1 1 1 0 0 0 00 0 0 0 2 2 2 2 0 0 0 00 0 0 0 3 3 3 3 0 0 0 00 0 0 0 4 4 4 4 0 0 0 00 0 0 0 5 5 5 5 0 0 0 00 0 0 0 6 6 6 6 0 0 0 00 0 0 0 7 7 7 7 0 0 0 00 0 0 0 2 2 2 23 3 3 3 5 5 5 59 9 9 9 Space heating cooling Domestic water hea...

Page 15: ...mestic hot water tank The disinfection function disinfects the domestic hot water tank by periodically heating the domestic hot water to a specific temperature 2 00 Operation interval day s of the week at which the domestic hot water should be heated 2 01 Status defines whether the disinfection function is turned on 1 or off 0 2 02 Start time time of the day at which the domestic hot water should ...

Page 16: ... information readout E 00 Readout of the software version example 23 E 01 Readout of the EEPROM version example 23 E 02 Readout of the unit model identification example 11 E 03 Readout of the liquid refrigerant temperature E 04 Readout of the inlet water temperature Space heating cooling always has priority over the disinfection function The disinfection function is only possible when the unit is ...

Page 17: ...o restart 00 Status 0 ON 0 1 4 Space heating off temperature 00 Installation related setting 01 Installation related setting 02 Space heating off temperature 25 14 25 1 C 03 Installation related setting 04 Installation related setting 5 Installation related settings 00 Installation related setting 01 Installation related setting 02 Installation related setting 03 Installation related setting 04 In...

Page 18: ...I O PCB 00 Solar priority mode setting 0 0 1 1 01 Installation related setting 02 Installation related setting 03 Installation related setting 04 Installation related setting D Local shift value weather dependent 00 Installation related setting 01 Installation related setting 02 Installation related setting 03 Local shift value weather dependent 0 0 1 2 3 4 E Unit information readout 00 Software v...

Page 19: ...gerant of oil and other parts must be done by a qualified installer in accordance with relevant local and national legislation Units must be treated at a specialized treatment facility for re use recycling and recovery By ensuring this product is disposed off correctly you will help to prevent potential negative consequences for the environment and human health Please contact the installer or loca...

Page 20: ...NOTES NOTES ...

Page 21: ......

Page 22: ...4PW56302 1 Copyright Daikin ...

Reviews: