Operation manual
11
EKHBH/XE008BA
Indoor unit for air to water heat pump system and options
4PW56302-1
Consulting domestic water heating, booster heater or quiet
mode
Consulting domestic water heating, booster heater or quiet mode is
carried out as follows.
1
Press the
<
button.
The actual mode is blinking.
2
Use the
pi
and
pj
buttons to select the mode you want
to consult (quiet mode
s
, booster heating
m
or domestic
water heating
w
).
The selected mode is blinking.
3
Press the
<
button to confirm the selected mode.
The first programmed action is displayed.
4
Use the
pi
and
pj
buttons to consult the programmed
actions.
This is called the readout mode. Empty program actions (e.g. 4
and 5) are not displayed.
By pressing the
pr
button several times, you return to previous
steps in this procedure and finally return to normal operation.
Tips and tricks
Programming the next day(s)
After confirming the programmed actions of a specific day (i.e. after
pressing the
<
button for 5 seconds), press the
pr
button once. You
can now select another day by using the
pi
and
pj
buttons
and restart consulting and programming.
Copying programmed actions to next day
In heating/cooling program it is possible to copy all programmed
actions of a specific day to the next day (e.g. copy all programmed
actions from "
1
" to "
2
").
To copy programmed actions to the next day, proceed as follows:
1
Press the
<
button.
The actual mode is blinking.
2
Use the
pi
and
pj
buttons to select the mode you want
to program.
The selected mode is blinking.
You can leave programming by pressing the
pr
button.
3
Press the
<
button to confirm the selected mode.
The actual day is blinking.
4
Select the day you would like to copy to the next day by means
of the
pi
and
pj
buttons.
The selected day is blinking.
You can return to step
by pressing the
pr
button.
5
Press the
<
and
pr
buttons simultaneously for 5 seconds.
After 5 seconds the display will show the next day (e.g. "
2
" if
"
1
" was selected first). This indicates that the day has been
copied.
You can return to step
by pressing the
pr
button.
Deleting one or more programmed actions
Deleting one or more programmed actions is done at the same time
as storing the programmed actions.
When all actions for one day have been programmed, make sure that
the display shows the highest action number you would like to save.
By pressing the
<
button for 5 seconds, you store all actions except
those with a higher action number than the one that is displayed.
E.g. when the
<
button is pressed when action number 3 is
displayed, actions 1, 2 and 3 are stored but 4 and 5 are deleted.
Deleting a mode
1
Press the
<
button.
The actual mode is blinking.
2
Use the
pi
and
pj
buttons to select the mode you want
to delete (quiet mode
s
, booster heating
m
or domestic water
heating
w
).
The selected mode is blinking.
3
Press the
<
and
ba
button simultaneously for 5 seconds to
delete the selected mode.
Deleting a day of the week (cooling or heating mode)
1
Use the
=
button to select the operation mode (cooling or
heating) you want to delete.
2
Press the
<
button.
The actual mode is blinking.
3
Press the
<
button to confirm the selected mode.
The actual day is blinking.
4
Select the day you would like to delete by means of the
pi
and
pj
buttons.
The selected day is blinking.
5
Press the
<
and
ba
button simultaneously for 5 seconds to
delete the selected day.
For installation with restricted power supply condition and
optional domestic hot water tank
The following information is valid when installing the optional
domestic hot water tank.
Simultaneous operation of compressor, backup heater and booster
heater is NOT possible. Refer to the following warnings mentioned in
the operation manual:
-
Emergency backup heater operation always has priority over
compressor or booster heater operation.
-
Balance between space heating/cooling demand and
domestic hot water demand.
To optimize the comfort balance between space heating/cooling and
domestic hot water, the schedule timers must be used.
The following shows step-by-step a possible space heating/cooling
and domestic hot water pattern. To ensure domestic hot water
production, the schedule timers must be used to disable space
heating/cooling. When space heating/cooling is disabled the
heatpump will switch automatically to domestic water heating. In this
case it is not required to program the domestic hot water or booster
heater schedule timer.
Example pattern
In this example, the domestic hot water tank will be heated between
2:00
and
4:00
.
Returning to previous steps in this procedure is done by
pressing the
pr
button.
Time
0
0
0
0::::0
0
0
00
0
0
0
111
1::::0
0
0
00
0
0
0
2
2
2
2::::0
0
0
00
0
0
0
3
3
3
3::::0
0
0
00
0
0
0
4
4
4
4::::0
0
0
00
0
0
0
5
5
5
5::::0
0
0
00
0
0
0
6
6
6
6::::0
0
0
00
0
0
0
7
7
7
7::::0
0
0
00
0
0
0
~
2
2
2
23
3
3
3::::5
5
5
59
9
9
9
Space
heating/cooling
If using a room thermostat, domestic water heating by
compressor or by booster heater is NOT possible as long
as the room thermostat demands cooling or heating.
In this case de-activate the room thermostat demand by its
schedule timer.
Refer to the manual of the room thermostat for a detailed
explanation how to de-activate space heating/cooling by
schedule timer, or refer to the separate addendum for an
example of the Daikin room thermostat schedule timer
programming.