Operation manual
15
EKHBH/X030BA
Indoor unit for air to water heat pump system and options
4PW62569-1 – 07.2010
Field settings table
Temperature values displayed on the digital controller (user interface) are default in °C.
To change the display to °F, push
ib
and
jb
buttons simultaneously for 5 seconds. Execute same procedure to change back to
the °C display.
First
code
Second
code
Setting name
Installer setting at variance with default value
Default
value
Range
Step
Unit
Date
Value
Date
Value
0
User permission level
00
User permission level
3
2/3
1
—
1
Weather dependent set point
00
Low ambient temperature (Lo_A)
14
(–10)
–4~41
(–20~5)
1.8
(1)
°F
(°C)
01
High ambient temperature (Hi_A)
59
(15)
50~68
(10~20)
1.8
(1)
°F
(°C)
02
Set point at low ambient temperature (Lo_TI)
104
(40)
77~131
(25~55)
1.8
(1)
°F
(°C)
03
Set point at high ambient temperature (Hi_TI)
77
(25)
77~131
(25~55)
1.8
(1)
°F
(°C)
2
Disinfection function
00
Operation interval
Fri
Mon~Sun,
All
—
—
01
Status
1 (ON)
0/1
—
—
02
Start time
23:00
0:00~23:00
1:00
hour
03
Set point
158
(70)
104~176
(40~80)
9
(5)
°F
(°C)
04
Interval
10
5~60
5
min
3
Auto restart
00
Status
0 (ON)
0/1
—
—
4
Space heating off temperature
00
Installation related setting
01
Installation related setting
02
Space heating off temperature
77
(25)
57.2~77
(14~25)
1.8
(1)
°F
(°C)
03
Installation related setting
04
Installation related setting
5
Installation related settings
00
Installation related setting
01
Installation related setting
02
Installation related setting
03
Installation related setting
04
Installation related setting
6
Installation related settings
00
Installation related setting
01
Installation related setting
02
Installation related setting
7
Installation related settings
00
Installation related setting
01
Installation related setting
02
Installation related setting
03
Installation related setting
04
Installation related setting
8
Installation related settings
00
Installation related setting
01
Installation related setting
02
Installation related setting
03
Installation related setting
04
Installation related setting