EKHBH/X030BA
Indoor unit for air to water heat pump system and options
4PW62569-1 – 07.2010
Operation manual
10
Programming quiet mode, booster heating or domestic water
heating
Programming domestic water heating, booster heater or quiet mode
is carried out as follows:
1
Press the
<
button.
The actual mode is blinking.
2
Use the
pi
and
pj
buttons to select the mode you want
to program (quiet mode
s
, booster heating
m
or domestic
water heating
w
).
The selected mode is blinking.
3
Press the
<
button to confirm the selected mode.
The first programmed action is displayed.
4
Use the
pi
and
pj
buttons to consult the programmed
actions.
This is called the readout mode. Empty program actions (e.g. 4
and 5) are not displayed.
5
Press the
<
button for 5 seconds to enter the programming
mode.
6
Use the
<
button to select the action number you would like to
program or to modify.
7
Use the
pi
and
pj
buttons to set the correct action time.
8
Use the
ba
button to select or deselect
x
as action.
9
Repeat steps 6 to 8 to program the other actions of the selected
mode.
When all actions have been programmed, make sure that the
display shows the highest action number you would like to save.
10
Press the
<
button for 5 seconds to store the programmed
actions.
If the
<
button is pressed when action number 3 is displayed,
actions 1, 2 and 3 are stored but 4 and 5 are deleted.
You automatically return to step 4. By pressing the
pr
button
several times, you return to previous steps in this procedure and
finally return to normal operation.
Returning to previous steps in the programming procedure
without saving modified settings is done by pressing the
pr
button.
4PW62569-1.book Page 10 Wednesday, June 30, 2010 12:13 PM
Summary of Contents for EKHBH030BA
Page 54: ...NOTES NOTES ...
Page 55: ......