background image

Operation manual

3

EKHBH/X016BB

Indoor unit and options for air to water heat pump system

4PW62573-1 – 10.2010

4.

O

PERATING

 

THE

 

UNIT

4.1.

Introduction

The heat pump system is designed to provide you a comfortable
indoor climate for many years at low energy consumption.

To  get the most comfort with the lowest energy consumption out of
your system, it is very important to observe the items listed below.

Defining possible schedule timer actions for each day and filling out
the form at the very end of this manual can help you minimize the
energy consumption. Ask your installer for support if required.

Make sure the heat pump system works at the lowest possible
hot water temperature required to heat your house.
To optimize this, make sure the weather dependent set point is
used and configured to match the installation environment.
Refer to 

"5. Field settings" on page 13

.

It is advised to install the room thermostat connected to the
indoor unit. This will prevent excessive space heating and will
stop the outdoor unit and the indoor circulation pump when the
room temperature is above the thermostat set point.

Next recommendations only apply to installations with an
optional domestic hot water tank.

Make sure the domestic hot water is only heated up to the
domestic hot water temperature you require.
Start with a low domestic hot water temperature set point
(e.g. 45°C), and only increase if you feel that the domestic
hot water supply temperature is not sufficient.

Only for tank with built-in electrical booster heater (EKHW*):
Make sure the domestic water heating by booster heater only
start 1 to 2 hours before you expect domestic hot water
usage.
In case you only need a lot of domestic hot water in the
evening or in the morning, only allow domestic water heating
by  booster heater during early morning and early evening.
Also keep hours with low electricity cost tariffs in mind.
To  do this, program both the domestic water heating and
booster heating schedule timer. Refer to 

Programming

  in

chapter 

"4.7. 

Programming and consulting the schedule

timer" on page 9

.

If the domestic hot water is not used for two weeks or more, a
quantity of hydrogen gas which is highly flammable may
accumulate in the domestic hot water tank. To dissipate this
gas safely, it is recommended that a hot tap be turned on for
several minutes at a sink, basin, or bath, but not at a
dishwasher, clothes washer or other appliance. During this
procedure there must be no smoking, open flame or any
electrical appliance operating nearby. If hydrogen is
discharged through the tap, it will probably make a sound as
of air escaping.

4.2.

Operating the digital controller

Operating the EKHB* unit comes down to operating the digital
controller.

Features and functions

The digital controller is a state of the art controller that offers full
control over your installation. It can control a heating/cooling and a
heating only installation.

Both installations are available in multiple versions which vary in
capacity, electrical supply and installed equipment (with an optional
domestic hot water tank).

Basic controller functions

The basic controller functions are:

Turning the unit ON/OFF.

Operation mode change-over:
-

space heating (refer to 

page 6

),

-

space cooling (refer to 

page 6

) (*),

-

domestic water heating (refer to 

page 6

) (*).

Selection of features:
-

quiet mode (refer to 

page 7

),

-

weather dependent control (refer to 

page 7

).

Temperature set point adjustment (refer to 

page 7

).

The digital controller supports a power cut off of maximum 2 hours.
When autorestart is enabled (see 

"5. Field settings" on page 13

) this

allows a power supply shut down of 2 hours without user intervention
(e.g. benefit kWh rate power supply).

Clock function

The clock functions are:

24 hour real time clock.

Day of the week indicator.

Schedule timer function

The schedule timer function allows the user to schedule the
operation of the installation according to a daily or a weekly program.

CAUTION

Never let the digital controller get wet. This may cause an
electric shock or fire.

Never press the buttons of the digital controller with a hard,
pointed object. This may damage the digital controller.

Never inspect or service the digital controller yourself, ask
a qualified service person to do this.

INFORMATION

Descriptions in this manual that apply to a specific
installation or that depend on the installed equipment,
are marked with an asterisk (*).

Some functions described in this manual may not be
available or should not be available. Ask your installer
or your local dealer for more information on
permission levels.

INFORMATION

(*) The functions 'space cooling' and 'domestic water
heating' can only be selected when the corresponding
equipment is installed.

Summary of Contents for EKHBH016BB3V3

Page 1: ...BB EKHBX016BB Indoor unit and options for air to water heat pump system EKHBH016BB3V3 EKHBH016BB6V3 EKHBH016BB6WN EKHBH016BB6T1 EKHBH016BB9WN EKHBH016BB9T1 EKHBX016BB3V3 EKHBX016BB6V3 EKHBX016BB6WN EK...

Page 2: ...this manual are classified according to their severity and probability of occurrence Some types of danger are represented by special symbols 1 2 Meaning of used terms Installation manual Instruction m...

Page 3: ...ent sizes 200 and 260 litre Solar kit for domestic hot water tank option For information concerning the EKSOLHW solar kit refer to the installation manual of that kit Room thermostat kit option An opt...

Page 4: ...ipate this gas safely it is recommended that a hot tap be turned on for several minutes at a sink basin or bath but not at a dishwasher clothes washer or other appliance During this procedure there mu...

Page 5: ...ATURE DISPLAY 9 The display shows the current space heating cooling set temperature of the installation 12 SETTING Not used For installation purposes only 13 NOT AVAILABLE n This icon is displayed whe...

Page 6: ...orage set point of the domestic hot water temperature only for 4 03 4 or 5 The buttons are not used when the domestic hot water tank is not installed 34 QUIET MODE BUTTON s This button enables or disa...

Page 7: ...int upon user request 2 Reheat Scheduled The unit will heat up the domestic water tank starting from a scheduled time and untill the reheat set point is reached Preferally this is done during the time...

Page 8: ...ng operation 1 Press v for 5 seconds to activate powerful domestic water heating operation For EKHW only Icons w and m start flashing 1 For EKHTS only Icons w and start flashing 2 Powerful domestic wa...

Page 9: ...iquid refrigerant temperature u The outdoor temperature w The domestic hot water temperature INFORMATION Only use the pr button to enable or disable the schedule timer The schedule timer overrules the...

Page 10: ...m at the very end of this manual This form can help you define the required actions for each day Keep in mind that In the space heating and domestic water heating program 4 actions can be programmed p...

Page 11: ...e programming mode 8 Use the button to select the action number you would like to program or to modify 9 Use the ba button to select For space heating x switch heating and the controller off 9 set the...

Page 12: ...select For space cooling x switch cooling and the controller off 9 set the temperature by means of the bi and bj buttons a to select automatic temperature calculation For quiet mode and booster heater...

Page 13: ...button The actual mode is blinking 2 Use the pi and pj buttons to select the mode you want to program The selected mode is blinking You can leave programming by pressing the pr button 3 Press the but...

Page 14: ...n 6 Repeat step 2 through 4 to change other field settings as required 7 When finished press the z button to exit FIELD SET MODE Detailed description 0 User permission level If required certain user i...

Page 15: ..._Ti the target outgoing water temperature when the outdoor temperature equals or rises above the high ambient temperature Hi2_A Note that the Hi2_Ti value should be lower than Lo2_Ti as for warmer out...

Page 16: ...nt hysteresis Example 1 Scheduled storage 6 03 1 scheduled reheat 6 05 1 disinfection function 2 01 1 activated A Scheduled storage operation activated at 6 04 heat up domestic hot water untill domest...

Page 17: ...ng automatic storage during night default setting If it seems that the domestic hot water night storage operation is not sufficient for your needs an additional scheduled reheat during daytime can be...

Page 18: ...it refer to the installation manual of that kit d Local shift value weather dependent Local shift value weather dependent The local shift value weather dependent field setting is only relevant in case...

Page 19: ...n All 01 Status 1 ON 0 1 02 Start time 23 00 0 00 23 00 1 00 hour 03 Set point only in combination with domestic hot water tank without electrical booster heater EKHTS 60 fixed 5 C 03 Set point only i...

Page 20: ...related setting 9 Heating and cooling set point ranges 00 Heating set point upper limit 55 37 55 1 C 01 Heating set point lower limit 25 15 37 1 C 02 Cooling set point upper limit 22 18 22 1 C 03 Coo...

Page 21: ...Unit information readout 00 Software version Read only 01 EEPROM version Read only 02 Unit model identification Do not change the default value depending on model 03 Liquid refrigerant temperature Re...

Page 22: ...nt of oil and other parts must be done by a qualified installer in accordance with the applicable legislation Units must be treated at a specialized treatment facility for re use recycling and recover...

Page 23: ......

Page 24: ...4PW62573 1 10 2010 Copyright 2010 Daikin...

Reviews: