Daikin EKCBH008BBV3 Operation Manual Download Page 5

EKCBX/H008BBV3

Unit for air to water heat pump system

4PW67442-1A – 12.2010

Operation manual

4

4.3.

Name and function of buttons and icons

1.

HEATING/COOLING ON/OFF BUTTON 

y

The ON/OFF button starts or stops the heating or cooling
function of the unit.

When the unit is connected with an external room thermostat,
this button is not operable and the icon 

e

 is shown.

Pressing the ON/OFF button consecutively too many times may
cause malfunction of the system (maximum 20 times per hour).

2.

OPERATION LED 

0

The operation LED is lit during space heating or space cooling
operation. The LED blinks if a malfunction occurs. When the
LED is OFF, space heating or space cooling are inactive while
the other operation modes can still be active.

3.

OPERATION MODE ICONS 

hcws

These icons indicate the current operation mode(s): space
heating (

h

), space cooling (

c

), domestic water heating (

w

) or

quiet mode (

s

). Within limits, different modes can be combined,

e.g. space heating and domestic water heating. The
corresponding mode icons will be displayed simultaneously.

In a heating only installation, the 

c

 icon will never be displayed.

If the domestic hot water tank is not installed, the 

w

 icon will

never be displayed.

If the solar option is installed and active, the 

w

 icon will be

blinking.

4.

EXTERNAL CONTROL ICON 

e

This icon indicates that the room thermostat (optional) with
higher priority is controlling your installation. This external room
thermostat can start and stop the space heating/cooling
operation and change the operation mode (heating/cooling).

When the external room thermostat with a higher priority is
connected, the schedule timer for space heating and space
cooling will not function.

When the benefit kWh power rate signal is sent, the centralised
control indication 

e

 will flash to indicate that benefit kWh power

rate is active.

5.

DAY OF THE WEEK INDICATOR 

1234567

This indicator shows the current weekday.

When reading or programming the schedule timer, the indicator
shows the set day.

6.

CLOCK DISPLAY 

8

The clock display shows the current time.

When reading or programming the schedule timer, the clock
display shows the action time.

7.

SCHEDULE TIMER ICON 

p

This icon indicates that the schedule timer is enabled.

8.

ACTION ICONS 

Q

These icons indicate the programming actions for each day of
the schedule timer.

9.

OFF ICON 

x

This icon indicates that the OFF action is selected when
programming the schedule timer.

10.

INSPECTION REQUIRED 

k

 and 

l

These icons indicate that inspection is required on the
installation. Consult your dealer.

11.

SET TEMPERATURE DISPLAY 

9

The display shows the current space heating/cooling set
temperature of the installation.

12.

SETTING 

$

Not used. For installation purposes only.

13.

NOT AVAILABLE 

n

This icon is displayed whenever a non-installed option is
addressed or a function is not available.

14.

DEFROST/STARTUP MODE ICON 

d

This icon indicates that the defrost/startup mode is active.

15.

COMPRESSOR ICON 

ç

This icon indicates that the compressor in the outdoor unit of the
installation is active.

16.

BACKUP HEATER STEP ONE 

(

 OR STEP TWO 

§

These icons indicate that the backup heater (if installed) is
operating on low capacity (

(

) or on high capacity (

§

). The

backup heater provides extra heating capacity in case of low
ambient outdoor temperature (high heating load).

17.

BOOSTER HEATER ICON 

m

This icon indicates that the booster heater is active. The booster
heater provides auxiliary heating for the domestic hot water tank.

The booster heater is located in the domestic hot water tank.

The icon is not used when the domestic hot water tank is not
installed.

18.

PUMP ICON 

é

This icon indicates that the circulation pump is active.

19.

OUTDOOR TEMPERATURE DISPLAY 

u

When this icon is flashing, the outdoor ambient temperature is
displayed.

20.

WEATHER DEPENDENT SET POINT ICON 

a

This icon indicates that the controller will adapt the temperature
set point automatically, based on the outdoor ambient
temperature.

21.

TEMPERATURE ICON 

b

This icon is displayed when the water outlet temperature of the
indoor unit, the outdoor ambient temperature and the domestic
hot water tank temperature are shown.

The icon is also displayed when the temperature set point is set
in schedule timer programming mode.

22.

TEST OPERATION ICON 

t

This icon indicates that the unit runs in test mode.

23.

FIELD SET CODE 

;

This code represents the code from the field set list. Refer to the

"Field settings table" on page 18

.

24.

ERROR CODE 

:

This code refers to the error code list and is for service purposes
only. Refer to the error code list in the installation manual.

INFORMATION

Remark that pushing the 

y

 button has no influence

on the domestic water heating. Domestic water
heating is only switched on or off by means of the

v

 button.

1

17

3

5

6

24

8

13

25

26

11

19

21

14

35
4

7

9

12
10

22

34

27

28

23

20

33

32

31

29

30

2

16

18

15

Summary of Contents for EKCBH008BBV3

Page 1: ...OPERATION MANUAL EKCBX008BBV3 EKCBH008BBV3 Unit for air to water heat pump system ...

Page 2: ... manual specified for a certain product or application explaining how to install configure and maintain it Operation manual Instruction manual specified for a certain product or application explaining how to operate it Maintenance instructions Instruction manual specified for a certain product or application which explains if relevant how to install configure operate and or maintain the product or appl...

Page 3: ...er Refer to the operation manual of the indoor unit and to the installation manual of the digital I O PCB for more information Refer to the wiring diagram or connection diagram for connecting this PCB to the unit Bottom plate heater EKBPHT refer to the installation manual option Remote thermostat kit option An optional room thermostat EKRTW EKRTWA or EKRTR can be connected to the indoor unit Refer...

Page 4: ...t tap be turned on for several minutes at a sink basin or bath but not at a dishwasher clothes washer or other appliance During this procedure there must be no smoking open flame or any electrical appliance operating nearby If hydrogen is discharged through the tap it will probably make a sound as of air escaping 4 2 Operating the digital controller Operating the unit comes down to operating the di...

Page 5: ...9 OFF ICON x This icon indicates that the OFF action is selected when programming the schedule timer 10 INSPECTION REQUIRED k and l These icons indicate that inspection is required on the installation Consult your dealer 11 SET TEMPERATURE DISPLAY 9 The display shows the current space heating cooling set temperature of the installation 12 SETTING Not used For installation purposes only 13 NOT AVAI...

Page 6: ...ting the clock 33 DOMESTIC HOT WATER TEMPERATURE ADJUST BUTTONS wbi and wbj These buttons are used to adjust the current set point of the domestic hot water temperature only for 4 03 0 1 2 or 3 These buttons are used to adjust the current storage set point of the domestic hot water temperature only for 4 03 4 The buttons are not used when the domestic hot water tank is not installed 34 QUIET MODE ...

Page 7: ...e unit will immediately heat up the domestic water tank untill domestic hot water storage set point upon user request 2 Reheat Scheduled The unit will heat up the domestic water tank starting from a scheduled time and untill the reheat set point is reached Preferally this is done during the time of day when space heating demand is lowest Continuous The unit will continuously heat up the domestic w...

Page 8: ...disappears from the display Selecting powerful domestic water heating operation 1 Press v for 5 seconds to activate powerful domestic water heating operation Icons w and m start flashing Powerful domestic water heating is deactivated automatically when the set point for the domestic hot water is reached Selecting quiet mode operation s 1 Use the s button to activate quiet mode operation s Icon s ap...

Page 9: ... hot water temperature INFORMATION Only use the pr button to enable or disable the schedule timer The schedule timer overrules the y button The y button only overrules the schedule timer until the next programmed action If the auto restart function is disabled the schedule timer will not be activated when power returns to the unit after a power supply failure Press the pr button to enable the sche...

Page 10: ...he schedule timer remind Familiarise yourself with the icons and the buttons You will need them when programming Refer to Name and function of buttons and icons on page 4 Fill out the form at the very end of this manual This form can help you define the required actions for each day Keep in mind that In the space heating and domestic water heating program 4 actions can be programmed per weekday The...

Page 11: ...e 8 Use the button to select the action number you would like to program or to modify 9 Use the ba button to select For space heating x switch heating and the controller off 9 set the temperature by means of the bi and bj buttons a to select automatic temperature calculation For domestic water heating use the ba button to enable or disable the x action 10 Use the pi and pj buttons to set the corre...

Page 12: ...on time 8 Use the ba button to select For space cooling x switch cooling and the controller off 9 set the temperature by means of the bi and bj buttons a to select automatic temperature calculation For quiet mode and booster heater mode use the ba button to enable or disable the x action 9 Repeat steps 6 to 8 to program the other actions of the selected mode When all actions have been programmed m...

Page 13: ... the next day e g copy all programmed actions from 1 to 2 To copy programmed actions to the next day proceed as follows 1 Press the button The actual mode is blinking 2 Use the pi and pj buttons to select the mode you want to program The selected mode is blinking You can leave programming by pressing the pr button 3 Press the button to confirm the selected mode The actual day is blinking 4 Select t...

Page 14: ...LD SET MODE The icon 3 will be displayed The current selected field setting code is indicated 2 with the set value displayed to the right 1 2 Press the bgi button to select the appropriate field setting first code 3 Press the bgj button to select the appropriate field setting second code 4 Press the pfi button and pfj button to change the set value of the select field setting 5 Save the new value by pr...

Page 15: ...perature Lo_A Note that the Lo_Ti value should be higher than Hi_Ti as for low outdoor temperatures i e Lo_A warmer water is required 1 03 Set point at high ambient temperature Hi_Ti the target outgoing water temperature when the outdoor temperature equals or rises above the high ambient temperature Hi_A Note that the Hi_Ti value should be lower than Lo_Ti as for warmer outdoor temperatures i e Hi...

Page 16: ... Scheduled domestic hot water storage The storage set point can be accessed directly using the wi and wj buttons 6 03 Scheduled storage defines whether the scheduled domestic water heating storage during night is enabled 1 or not 0 6 04 Scheduled storage start time time of the night at which the domestic water should be heated CAUTION The disinfection function field settings must be configured by the...

Page 17: ...estic hot water user interface set point 9 Heating and cooling set point ranges The purpose of this field setting is to prevent the user from selecting a wrong i e too hot or too cold leaving water temperature Thereto the heating temperature set point range and the cooling temperature set point range available to the user can be configured 9 00 Heating set point upper limit maximum leaving water tem...

Page 18: ...ld settings of the weather dependent set point 1 E Unit information readout E 00 Readout of the software version example 23 E 01 Readout of the EEPROM version example 23 E 02 Readout of the unit model identification example 11 E 03 Readout of the liquid refrigerant temperature E 04 Readout of the inlet water temperature INFORMATION Remark that the b icon will be flashing during setback operation The...

Page 19: ...heating off temperature 00 Installation related setting 01 Installation related setting 02 Space heating off temperature 25 14 25 1 C 03 Installation related setting 04 Not applicable Do not change the default value 05 Not applicable Do not change the default value 06 Installation related setting 07 Installation related setting 5 Installation related setting 00 Installation related setting 01 Inst...

Page 20: ...elated setting 05 Not applicable Do not change the default setting d Local shift value weather dependent 00 Installation related setting 01 Installation related setting 02 Installation related setting 03 Local shift value weather dependent 0 OFF 0 1 2 3 4 1 04 Not applicable Do not change the default value 05 Installation related setting 06 Not applicable Do not change the default value E Unit inf...

Page 21: ...lified installer in accordance with relevant local and national legislation Units must be treated at a specialized treatment facility for re use recycling and recovery By ensuring this product is disposed off correctly you will help to prevent potential negative consequences for the environment and human health Please contact the installer or local authority for more information DANGER Do not touch...

Page 22: ...NOTES NOTES ...

Page 23: ......

Page 24: ...Copyright 2010 Daikin 4PW67442 1A 12 2010 ...

Reviews: